Who we are, and what we make
We are a manufacturer of industrial weighing equipment in Changzhou, Jiangsu. Our main product line is weighing modules. We run a 6,000 m² production area and two standard workshops, keep a 1,000 m² stock warehouse, have been in this business over a decade, have served more than a hundred industrial customers, and take on custom-built and OEM work.
| Item | Detail | Source |
|---|---|---|
| Main product line | Weighing modules | our own |
| Other product lines | Load cells, weighing indicators, junction boxes, weight transmitters, platform scales, bench scales, explosion-proof versions | our own, plus our published product categories |
| Production scale | 6,000 m² production area; 2 standard workshops; 1,000 m² stock warehouse | our own (not previously published) |
| Time in the business | over a decade (no start date is published, so none is stated here) | our own |
| Customer base | Over a hundred industrial customers served | our own |
| Capabilities | Custom-built units; OEM / private label | our own |
| Total investment | RMB 28.7 million | company figures, confirmed by management |
| Annual turnover | over RMB 80 million | company figures, confirmed by management |
| Location | Changzhou, Jiangsu, China | our own |
| Address | No. 21 Tianshan Road, Xinbei District, Changzhou, Jiangsu, China | confirmed by management 2026-09-30 |
| Phone | +86 183 51238137 | confirmed by management 2026-09-30 |
| Message us on WhatsApp | confirmed by management 2026-10-01 |
Product lines: what we make, and which models
Weighing modules (main product line)
What is a weighing module? A weighing module is the part that turns a vessel into a scale. It consists of a top plate, a base plate, a load cell, a load-carrying column and support bolts. Fit weighing modules to a tank, hopper or reactor and it becomes a weighing system. (From public technical material, restated by the manufacturer.)
How is it different from a bare load cell? A module adds resistance to off-centre loading, a limit-stop structure and the mounting hardware. For service, the support screw jacks the vessel up so the load cell can be replaced without taking the module apart. (From public technical material.)
Which capacities do our modules cover? Two module structures cover 0.22–2.2 t / 4.4 t / 9 t / 13.6 t / 20 t and 0.5–3 t / 5 t / 10 t / 15–20 t (our drawings, 2026-09-12). Our current models are listed below. The final specification is confirmed against your duty.
| Model (our range) | Capacity steps |
|---|---|
HY-UW-M / HY-UW / HY-UWS / HY-UWS-M | 5 kg, 10 kg, 20 kg, 30 kg, 50 kg, 75 kg, 100 kg, 200 kg, 300 kg, 500 kg |
HY-CW / HY-CWC / HY-CW-M / HY-FW / HY-FW-M | 0.5 t, 1 t, 2 t, 3 t, 5 t, 8 t, 10 t, 15 t, 20 t |
HY-CWC-M | 0.5 t, 1 t, 2 t, 3 t, 5 t, 10 t, 15 t, 20 t |
HY-FWC-M | 0.22 t, 0.55 t, 1.1 t, 2.2 t, 9 t, 13.6 t, 20 t |
HY-GW / HY-GWC | 15 t, 20 t, 30 t, 50 t, 100 t |
| Fixed modules / fully floating modules | No specifications are published for these two types |
Source: our product data (inventoried 2026-09-30).
Published module models cover steps from 5 kg to 100 t (the HY- prefix); the capacity figures in our product data, whose specification tables's specification tables are authoritative. The final specification is confirmed against your duty.
Load cells
Our load cell range covers many models (the HY- prefix). Representative specifications from HY-SBS-M:
| Parameter | Published value |
|---|---|
| Rated output | 2 ± 0.002 mV/V |
| Non-repeatability | ≤ 0.01 % R.C. |
| Hysteresis / non-linearity | ≤ 0.02 % R.C. |
| Creep (30 min) | ≤ 0.02 % R.C. |
| Zero balance | ≤ 1 % R.C. |
| Compensated / operating temperature | −10 to +40 °C / −20 to +60 °C |
| Input / output resistance | 381 ± 4 Ω / 350 ± 1 Ω |
| Insulation resistance | ≥ 5,000 MΩ (50 V DC) |
| Recommended / maximum excitation | 5–15 V / 20 V |
| Safe / ultimate overload | 150 % / 300 % |
| Standard cable | 3 m |
Source: our product data (inventoried 2026-09-30).
High-capacity column models (for example HY-GD-M at 15–100 t and HY-PGD-M at 2–50 t) are published with a rated output of 2 mV/V or 1 mV/V, safe overload of 150 % or 200 %, ultimate overload of 300 % or 500 %, and a 13 m cable. (Source: our product data, inventoried 2026-09-30.)
Ingress protection: confirmed by model and site conditions.
Weighing indicators, junction boxes and weight transmitters
- Weighing indicators: our model pages include
HY-IND232andHY-IND232+; explosion-proof indicators are also available (see below). - Junction boxes: stainless steel junction boxes are part of the range.
- Weight transmitters: these convert the load cell signal into the output your control system needs. The exact output is confirmed by configuration.
Platform scales and bench scales
- Platform scales: published standard sizes run from 800 × 800 to 1,500 × 2,000 mm, with 1 to 4 load cells of 350 Ω, an AC 100–240 V supply and an operating temperature of −10 to 40 °C (source: our product data, 2026-09-30).
- Bench scales: standard sizes from 300 × 400 to 600 × 800 mm; the overload alarm is set at 0.15 % above maximum capacity (source: our product data).
Explosion-proof weighing
Can you supply weighing for a hazardous area? Yes. Explosion-proof versions are available (Ex ia IIC T6); the exact configuration is confirmed against your working conditions. (our own, 2026-10-01.)
Which duty does your vessel fall under?
Buyers usually arrive with a vessel and a problem rather than an industry keyword. These are the four most common cases. Open one to see how that case is handled.
-
Vertical process tanks and mixing tanks (mostly retrofits)
Module count follows the number of existing support legs (3 legs → 3 modules, 4 legs → 4 modules). After installation, first check that the nuts on top of the support screws have been released.
How weighing is added to a vertical or mixing tank → Work out the capacity with the sizing formula → -
Silos and storage towers (high capacity, dust)
High-capacity vessels usually take one high-capacity module per leg, three or four in total, fitted under the legs. In dusty areas the priorities are keeping the junction box dry and limiting horizontal movement.
Configuration points for silos and towers → -
Reactors (agitation, thermal movement, often hazardous areas)
Agitation and thermal expansion push side loads into the modules, so add limit stops and keep the load vertical. Explosion-proof configuration is confirmed against your working conditions.
How reactor weighing handles side loads → -
Batching lines and multi-scale systems
One scale's accuracy is not system accuracy: an additive recipe multiplies the error of each scale. Set "zero on power-up" to disabled on vessel scales.
How a batching line is configured → What to check when the numbers jump or reset →
Why work with us
Facts that can be checked. No adjectives.
| What buyers ask | Facts that can be checked | Source |
|---|---|---|
| Are you the actual factory? | Our own 6,000 m² production area and 2 standard workshops; the range runs from load cells and modules to indicators and junction boxes, all made in-house | our own |
| Can you supply volume, and is it consistent batch to batch? | A 1,000 m² stock warehouse; over a hundred industrial customers served; OEM / private label supported for repeat supply | our own |
| Can you build special sizes or capacities? | Custom-built units; flanges, mounting hole spacing and similar details are confirmed against your drawing | our own |
| What if I cannot work out the sizing? | The sizing formula, a worked example and the acceptance method are published on this site (/en/selection/), and you can call us | This site |
| Who do I contact if something is wrong after installation? | Call +86 183 51238137; the eight most common installation faults are published at /en/faq/ and /en/selection/ | our own |
| Lead time | Standard items: some ex stock, others about 1 week; custom and non-standard items are confirmed against the order specification | — |
| Warranty | 12 months | — |
| How long have you been in this business? | over a decade | our own |
| Investment and trading scale | Total investment RMB 28.7 million; annual turnover over RMB 80 million — company figures, confirmed by management | company figures, confirmed by management |
How we work together
The usual sequence is:
- Site survey
- Concept and sizing
- Confirm the sequence and the functions
- Contract
- Dispatch
- Implementation on site
- Operator training
- System acceptance
- Handover
- After-sales support
(The service flow framework follows our own service process.)
If one step is stuck, tell us the site conditions and we can work through that step with you.
What to send us
Seven items cover the sizing and the configuration. If you do not have all of them, send what you know and we fill the gaps in the conversation.
- The vessel or silo weight (include agitators, jackets, insulation and fittings).
- The product name and the maximum load.
- The number of modules planned, or the number of existing support legs.
- The installation space: leg size, available height, leg spacing, and whether the floor can be altered.
- Any hazardous-area, corrosion or hygiene requirement.
- Where the weight signal goes: a local indicator, or a PLC / DCS / host system.
- The date you need it.
Send your vessel type, capacity and quantity.
If WhatsApp does not open, call +86 183 51238137.
How to reach us, and where we are
Address: No. 21 Tianshan Road, Xinbei District, Changzhou, Jiangsu, China
Interested? Message us on WhatsApp.