First published:

You are here: Home > Products

Weighing Modules and Load Cells: 13 Modules, 28 Load Cells, 2 Structure Types

Weighing modules for vessels, tanks, silos, reactors and batching lines. This page lists the models documented on this site, grouped by capacity. Each model links to its own page with parameters, wiring colour code, dimensions and drawings. Documentation completeness differs between models, and each product page states plainly what is and is not available.

Not sure which capacity fits your vessel? Describe the vessel:

+86 183 5123 8137

Tap to dial on a phone. WhatsApp works on the same number.

How do I use this page?

Find the group that matches your vessel capacity, then compare material and wiring against the site conditions, then open the model page to check parameters and drawings. If you have not calculated the load yet, start with the sizing formula on the Selection & Resources page.

Which models cover 5 kg to 500 kg?

Bellows-type modules, 10 capacity steps from 5 kg to 500 kg. All four models use a stainless-steel hermetically sealed load cell, IP68 protection and 6-wire connection.

Small-capacity modules (5 kg to 500 kg, 10 steps)
Model Capacity Material & wiring Page
HY-UW 5 kg to 500 kg (10 steps) Stainless steel, hermetically sealed, IP68, 6-wire HY-UW details
HY-UW-M 5 kg to 500 kg (10 steps) Identical documentation to HY-UW HY-UW-M details
HY-UWS 5 kg to 500 kg (10 steps) Identical documentation to HY-UW HY-UWS details
HY-UWS-M 5 kg to 500 kg (10 steps) Identical documentation to HY-UW HY-UWS-M details

The four models share identical company documentation for the three key items (main features, wiring, capacity); the documentation does not state any difference between them.

Which models cover 0.5 t to 20 t?

Shear-beam modules for 0.5 t to 20 t, in dynamic-load and static-load versions. These four models differ in material, wire count and protection rating, so check them one by one.

Mid-capacity modules (0.5 t to 20 t)
Model Capacity Material & wiring Page
HY-CWC 0.5 t to 20 t (9 steps) Dynamic load, 4-wire with shield HY-CWC details
HY-CWC-M 0.5 t to 20 t (8 steps) Stainless steel, hermetically sealed, IP68, 6-wire, static load HY-CWC-M details
HY-CW 0.5 t to 20 t (9 steps) Stainless steel, 4-wire HY-CW details
HY-CW-M 0.5 t to 20 t (9 steps) Alloy steel, nickel-plated, 6-wire with shield HY-CW-M details

Which models are for tank batching?

Three models for batching control on tanks and vessels.

Tank batching modules
Model Capacity Material & wiring Page
HY-FW 0.5 t to 20 t (9 steps) Alloy steel, nickel-plated, 4-wire HY-FW details
HY-FW-M 0.5 t to 20 t (9 steps) Alloy steel, nickel-plated, 6-wire with shield HY-FW-M details
HY-FWC-M 0.22 t to 20 t (7 steps) Stainless steel, hermetically sealed, IP68, 6-wire HY-FWC-M details

Which model covers 15 t to 100 t?

Column-type module for large tanks, with tie rods and angle brackets for lateral restraint.

Heavy-duty modules (15 t to 100 t)
Model Capacity Material & wiring Page
HY-GW 15 t, 20 t, 30 t, 50 t, 100 t (5 steps) Stainless steel, hermetically sealed, IP68, 6-wire, stainless mounting plate HY-GW details

Which load cell covers 5 kg to 500 kg?

Column-type cell with low mounting height, stainless steel and hermetically welded, IP68; for packing scales, belt scales and batching control.

Load cell
Model Capacity Key specifications Page
HY-MTB-M 5 kg to 500 kg (10 steps) Stainless steel, hermetically welded, IP68, 6-wire, safe overload 150% HY-MTB-M details
HY-MTB 5 kg to 500 kg (10 steps) Stainless steel, hermetically welded, IP68, 4-wire (no sense), safe overload 150% HY-MTB details
HY-1241 30 kg to 250 kg (5 steps) Single point, corner errors compensated, laser-welded, 4-wire HY-1241 details
HY-SSP-IL 150 kg to 2000 kg (5 steps) Single point, large platform, impact-rated, 6-wire, IP67 HY-SSP-IL details
HY-SBD 15 t to 50 t (5 steps) Double shear beam, alloy steel nickel-plated, 4-wire, 13 m cable HY-SBD details
HY-SBS-M 0.5 t to 3 t (4 steps) Self-stabilising, low profile, alloy steel nickel-plated, 6-wire HY-SBS-M details
HY-SBT 0.5 t to 2 t (3 steps) Low profile, alloy steel nickel-plated, 4-wire, outline differs from HY-SBS (137 / M12) HY-SBT details
HY-SQB (0.5-5 t) 0.5 t to 5 t (5 steps) Low profile, alloy steel nickel-plated, 4-wire, two sensitivity values documented; a 100-300 kg version also exists HY-SQB (0.5-5 t) details
HY-SSH 50 kg to 1000 kg (6 steps) Stainless steel, laser-welded, IP68 (highest here), 6-wire, for food/pharma/chemical duty HY-SSH details
HY-SSP1022 3 kg to 30 kg (7 steps) Single point, laser-welded IP67, 4-wire, 2 m cable (HY-1022 is 1 m; otherwise identical) HY-SSP1022 details
HY-SSP1241 30 kg to 250 kg (5 steps) 6-wire with sense, IP67, red and green swapped vs HY-1241, overall 150 (HY-1241 is 174) HY-SSP1241 details
HY-SSP1260 100 kg to 750 kg (8 steps) 6-wire (as SSP1241), IP67; 3 overlapping steps with SSP1241; dimension drawing names MT1260 and is not used HY-SSP1260 details
HY-QS 15 t to 50 t (5 steps) Double shear beam, 4-wire, protection and overload split by capacity (40-50 t drops to 120%/200%), excitation max 15 V HY-QS details
HY-0743-M 9 t / 13.6 t / 20 t (3 steps) 6-wire, IP68, 9 m cable, sensitivity 1.94 (not 2.0); M suffix but the photographs show the bare cell HY-0743-M details
HY-0745A-M 0.22 t to 4.4 t (5 steps) Same parameters as HY-0743-M, differing in capacity and cable (4.5 m); legible capacity table reproduced in full (14 columns) HY-0745A-M details
HY-HLJ-M 0.5 t / 1 t / 2 t / 3 t (4 steps) Self-stabilising, 4-wire, IP68, 5 m cable, two sensitivity values (2 / 3.0, no mapping stated) HY-HLJ-M details
HY-SBC-M 0.5 t / 1 t / 2 t / 3 t (4 steps) Self-stabilising, 4-wire, IP67, -40 to +65 °C (low floor), 3.1 m cable HY-SBC-M details
HY-SBH-M 0.5 t / 1 t / 2 t / 3 t (4 steps) Stainless steel, compact, 4-wire, 5 m cable; protection documented two ways (IP68 in features / IP67 in table) HY-SBH-M details
HY-SB-M 0.5 t to 20 t (9 steps, the most) Self-stabilising, 6-wire, IP67, 4 m cable; the only model above 5 t (8/10/15/20 t) HY-SB-M details
HY-GD-M 15 t to 100 t (5 steps) Column type (self-stabilising rocker), stainless IP68, 6-wire, 1160/1000 Ω (highest here), 13 m cable HY-GD-M details
HY-SQB (100-300 kg) 100 kg / 200 kg / 250 kg / 300 kg (4 steps) 4-wire, IP67, 3 m cable; same name and identical parameters as HY-SQB (0.5-5 t), differing only in capacity HY-SQB (100-300 kg) details
HY-0805 0.5 t / 1 t / 2 t (3 steps) Compact, self-stabilising, 4-wire, IP67, 3 m cable; same parameters as HY-SBT but a different outline (167 / 58) HY-0805 details
HY-PGD-M 2 t / 5 t / 10 t / 20 t / 30 t / 50 t (6 steps) Column, stainless IP68, 6-wire, sensitivity 1.0 (the only one), 200%/500% overload (highest) HY-PGD-M details
HY-SB 0.5 t to 20 t (9 steps) Self-stabilising, 4-wire, IP67, 4 m cable; differs from HY-SB-M only in wiring (4-wire vs 6-wire), everything else identical HY-SB details
HY-PST 20 kg to 5 t (15 steps, the most) S-type, laser-welded, IP68 (1.2-5 t) / IP65, 4-wire; sensitivity 2±0.003, output 352±3, excitation 10-12 V, safe overload 120% (lowest) HY-PST details
HY-TSH-M 200 kg / 300 kg / 500 kg / 1 t / 2 t / 3 t / 5 t (7 steps) S-type, stainless laser-welded IP68, 6-wire, 5 m cable, +65 °C upper limit; complete 6-row dimension table HY-TSH-M details
HY-SBS 0.5 t to 3 t (4 steps) Low profile, alloy steel nickel-plated, 4-wire (no sense), IP67 HY-SBS details
HY-1022 3 kg to 30 kg (7 steps) Single point, small capacity, laser-welded, IP67, 1 m cable HY-1022 details

What do "fixed" and "full-floating" mean?

"Fixed" and "full-floating" are not model numbers. They describe how the load-bearing column and top plate are arranged. A typical system uses one fixed module, one semi-floating module, and full-floating modules for the rest, so full-floating modules are the most numerous in most installations.

Structure types
Type Role in a system Page
Fixed weighing module One per system Fixed weighing module details
Full-floating weighing module All remaining positions (most modules) Full-floating weighing module details

Not sure which capacity? Calculate first

The model is chosen from the calculated load per module, not from the size of the vessel. The sizing method, worked examples, four application types and the eight installation faults are on the Selection & Resources page and in the FAQ.

dead load + live load ≤ rated capacity × number of modules × 70%

The 70% factor is the usual industry margin, quoted from public technical literature.

What is the scope of this page?

Where do the facts come from?

Values are transcribed from company documentation. Final specifications are confirmed against the order and application.

Still unsure?

Call +86 183 5123 8137