How does it split from HY-0743-M?
Short answer: the features, the 6-wire colour order and all 19 parameters are word-for-word identical. Only two things differ: the capacity ladder and the cable length. This one covers the smaller range (0.22–4.4 t); HY-0743-M covers 9–20 t.
| Item | HY-0745A-M (this page) | HY-0743-M |
|---|---|---|
| Capacity | 0.22 to 4.4 t, 5 steps | 9 to 20 t, 3 steps |
| Sensitivity | 1.94±0.002 | 1.94±0.002 (same) |
| Other 18 parameters | identical | identical |
| Features | 5 lines, word-for-word same | 5 lines, word-for-word same |
| Wiring | 6-wire, same colour order | 6-wire, same colour order |
| Cable | 4.5 m | 9 m |
⚠️ Selection comes down to one number: the load per cell. 0.22–4.4 t takes this model; 9–20 t takes HY-0743-M. Both are 1.94, so they are electrically interchangeable (still re-calibrate), but their capacity ranges are far apart and they cannot substitute for one another.
How is it wired?
Short answer: 6-wire. The text, the label on the unit and the wiring diagram all agree.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| long yellow | shield | Shield |
⚠️ The shield has now appeared in three different wordings across this factory's documents: this unit's label says "long yellow", the HY-SBT label says "thick yellow", and the drawings say pale-yellow. All mean the same thing; the actual wire governs. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 1.94±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP68 |
| Cable length | m | 4.5 |
IP68 covers continuous immersion, steadier than IP67 where a batching area is washed down.
What are the dimensions? ⭐ This drawing table is legible
Short answer: the drawing carries a clearly legible capacity table (titled "0745A"), grouped as 0.22–1.1 t / 2.2 t / 4.4 t with 14 columns. It is reproduced in full below. Units are not marked on the drawing and none are added here.
| Capacity / t | A | B | C | D | E | F | G | H | K | R | M | P | Q | S |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.22–1.1 | 153.9 | 15.4 | 76.2 | 25.4 | 30.2 | 35.7 | 57.7 | 17.3 | 4.5 | 12.7 | 22.2 | 15.9 | 3.1 | 7.9 |
| 2.2 | 158.6 | 15.4 | 76.2 | 25.4 | 30.6 | 36.9 | 57.8 | 22.9 | 8.2 | 12.7 | 22.2 | 15.9 | 3.1 | 12.7 |
| 4.4 | 171.5 | 21.4 | 95.2 | 35.1 | 42.9 | 42.9 | 73.8 | 28.3 | 10.8 | 19.05 | 34.9 | 22.2 | 0 | 17.8 |
⚠️ Read the three rows carefully: 0.22 / 0.55 / 1.1 t share one set; 2.2 t is its own row, and 4.4 t another, with A (overall length) growing 153.9 → 158.6 → 171.5. Use the row for your capacity — do not fit a 4.4 t unit with 0.22 t hole spacing. The drawing also marks the relief cut-out and the sealant area.
What does it look like?
Short answer: five images are supplied — product photographs, one dimension drawing with the capacity table, and one wiring diagram. This page uses one photograph plus both drawings.
⚠️ This is one of the few legible capacity tables in the factory's material (most are too small to read), so all 14 columns are reproduced here for direct use when drilling.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and batching in chemical, food and pharmaceutical plants, 0.22 to 4.4 t.
The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: medium-to-small capacity batching; chemical, food and pharmaceutical dosing; sites needing IP68 (continuous immersion).
- Why IP68: batching areas are washed down; IP67 only covers brief immersion.
- ⚠️ Sensitivity 1.94: unlike the 2.0 of most siblings — recalibrate on replacement or when paralleling.
- Not covered: 9–20 t (use HY-0743-M); small bench platforms (single point); 4-wire indicators.
How can I tell whether the cell has failed?
Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
Resistances and sensitivity are different things: normal resistances do not prove the sensitivity is right. Check sensitivity against the marking or the shipping documentation.
Where do the facts come from?
- Company product documentation: five features, 6-wire colour code, 5 capacity steps, 19 technical parameters.
- Company images (five): product photographs, a dimension drawing with the legible capacity table, and a wiring diagram.
- Check against HY-0743-M: both pages (parameters word-for-word the same; capacity and cable differ).
- Public technical literature: how sensitivity differences affect parallel sharing and calibration, IP67 versus IP68.
Values are transcribed from company documentation and are not a commitment for a specific project.