What is it, and how does it differ from column and single-point types?
Short answer: a double shear beam is a third structure — fixed at both ends, loaded in the middle, working through two shear planes. In this factory's range: single-point covers small platforms, column covers vessels and hoppers, double shear beam covers large-capacity platforms.
| Structure | Models | Typical capacity | Typical equipment |
|---|---|---|---|
| Single point | HY-1241 / HY-SSP-IL | 30 kg to 2000 kg | bench, packing and flour scales |
| Column | HY-MTB / HY-MTB-M | 5 kg to 500 kg | packing scales, belt scales, batching |
| Double shear beam | HY-SBD (this page) | 15 t to 50 t | truck scales, rail scales |
The company documentation says "for truck scales and rail scales". That describes where the component is used — this cell is fitted to such large platforms — not that this factory builds complete platforms.
How is it wired? What should be noted with a 13 m cable?
Short answer: 4-wire. The text and the drawing agree wire for wire, and the drawing adds pale-yellow = Shield.
| Colour | Terminal | Function |
|---|---|---|
| Red | +input | + excitation |
| Black | −input | − excitation |
| Green | +output | + signal |
| White | −output | − signal |
| pale-yellow | Shield | Shield (drawing only) |
⚠️ One technical point worth flagging: the supplied cable is 13 m — a long run — while the cell is 4-wire (no sense pair). With 4-wire, the excitation voltage drops along the cable; the longer the run, the larger the deviation at the bridge, and the reading follows it. This is a limitation of the wiring, not a fault. Where it matters (long runs, thin conductors), evaluate the actual circuit or pair it with compensation at the indicator. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters. Note that the resistances are about twice those of the other ranges (input 772 Ω, output 700 Ω) — a characteristic of the double shear beam.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -40 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 772±4 |
| Output resistance | Ω | 700±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 13 |
⚠️ When checking a cell, the reference values for this model are 772 / 700 Ω — do not apply the 387 / 350 Ω of the other ranges.
What are the dimensions?
Short answer: the drawing carries several views; the product page text has no dimension table. Units are not marked and none are added here.
| Part | Values shown |
|---|---|
| Top / side | 40, 15, 63, 68; details 3, 20, 36, 57, 12, 12, 17 |
| Two other views | 130, 52, 43.5, 61.5; end faces 45, 10 |
| Mounting | 2-Φ hole callouts and M thread callouts shown indicatively |
The drawing is a multi-view sheet: wiring diagram, top/side/end views, plus a junction-box sketch (labelled "Hengyuan 4-core, steel"). Units are unmarked; where it disagrees with the unit, the unit and shipping documentation govern.
What does it look like?
Short answer: four photographs and one drawing are supplied. This page uses one photograph plus the drawing — the other two photographs are e-commerce listing images carrying "HOT", "factory direct" and "quality guaranteed" banners, which are not used here.
Two further photographs were not used because they carry marketing banners (HOT / factory direct / quality guaranteed) — claims this site does not make. Where an image and the written documentation disagree, the written documentation governs.
Where does it fit, and where does it not?
Short answer: the documented applications are truck scales and rail scales. What those have in common: high capacity, long platforms, several cells in parallel.
- Fits: vehicle-weighing platforms and rail weighing; parallel banks where each cell carries 15 to 50 t.
- Count and capacity: large platforms usually run several cells in parallel; match the rated capacity to the total load and the cell count, with the usual industry margin (see selection).
- ⚠️ 13 m cable with 4 wires: long run, no sense pair — excitation drop lands in the reading. This is the one point to watch on this model.
- Not covered: small platforms and low capacities (single point or column fits); vessel batching (column modules); systems that require sense-wire compensation.
How can I tell whether the cell has failed?
Short answer: input across red/black 772±4 Ω, output across green/white 700±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 772±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 700±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
⚠️ On a parallel bank, disconnect the other cells at the junction box before measuring one, otherwise the reading is the parallel value and you will misjudge it.
Where do the facts come from?
- Company product documentation: series name (SBD double shear beam), seven features, 4-wire colour code, 5 rated capacities, 19 technical parameters.
- Company drawing (one multi-view sheet): wiring diagram, top/side/end views, junction-box sketch.
- Positioning against the other two structures: the single-point and column product pages.
- Public technical literature: double shear beam load paths, excitation drop over long cables, field checks on parallel banks.
Values are transcribed from company documentation and are not a commitment for a specific project.