What is it, and how does it differ from HY-1241?
Short answer: both are single-point cells. The difference is platform size and capacity: HY-1241 stops at 250 kg, this one goes to 2000 kg. This model is 6-wire; HY-1241 is 4-wire.
| Item | HY-SSP-IL (this page) | HY-1241 |
|---|---|---|
| Capacity | 150 to 2000 kg (5 steps) | 30 to 250 kg (5 steps) |
| Platform | Large platform, with impact | Bench scales, packing scales, process weighing |
| Wiring | 6-wire with sense | 4-wire |
| Material | Stainless steel | Laser-welded seal |
| Protection | IP67 (consistent in both places) | IP65 / IP67 (that page explains the conflict) |
The shared value of a single-point cell is the factory-compensated corner errors: a load moved around the platform reads the same. This model adds "large platform, with impact" — both of which raise the demand on platform stiffness and mounting.
How is it wired?
Short answer: 6 wires. The product page text and the wiring diagram on the drawing agree wire for wire.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| pale-yellow | shield | Shield |
The sense pair compensates excitation drop on long runs. Earth the shield at one end only. ⚠️ Note that green/red mean the opposite of some sibling models here (this model: green = excitation+, red = signal−). Wire by this page and the unit, never by colour carried over from another model.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±15 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 2.5 |
The protection rating is consistent in both places (IP67) — unlike HY-1241, whose documentation contradicts itself.
What are the dimensions? Capacity-grouped table
Short answer: the dimension data sits only on the drawing (the product page text leaves "Dimensions:" empty). The drawing carries a table grouped by capacity, transcribed here.
| Capacity / kg | A | A1 | B | B1 | C | E |
|---|---|---|---|---|---|---|
| 150–1000 | 72 | 46 | 64 | 38 | 150 | M14 |
| 2000 | 80 | 55 | 72 | 42 | 150 | M16 |
Two notes: ① column E is a thread size (M14 / M16), not a length; ② units are not marked on the drawing and none are added here. The drawing also shows mounting holes marked "4-Φ both ends", the cable exit at 18, and the position of the waterproof sealant (yellow areas in the side view) — all three are indicative only, with no numeric value given.
What does it look like?
Short answer: the documentation contains five photographs and one drawing. This page shows the drawing only: in the photographs the nameplate is either covered by a white sticker or out of focus, so none is published here.
No usable product photograph is published for this model. Where an image and the written documentation disagree, the written documentation governs.
Where does it fit, and where does it not?
Short answer: the documented applications are large platforms with impact — bench scales, flour scales, belt scales. Those two words set two prerequisites: a stiff platform and a foundation that takes the impact.
- Fits: large-platform bench scales, flour scales, belt scales; where loading has impact, or a hopper/forklift feeds the platform.
- Capacity limit: 150 to 2000 kg. The 2000 kg step uses M16 threads (M14 for 150–1000 kg) — match bolts and holes to the step.
- Prerequisite 1 (platform stiffness): with a large platform, the platform's own deflection lands directly in the reading. No corner compensation can rescue a flimsy platform.
- Prerequisite 2 (impact): impact amplifies the instantaneous load. "Static weight is under the rating" is not the test — which is why static and dynamic duties at the same tonnage are selected separately.
- Not covered: small platforms and low capacities (HY-1241 fits better); aggressive media; larger single-cell loads.
How can I tell whether the cell has failed?
Short answer: three measurements — input across green/black 381±15 Ω, output across white/red 350±1 Ω, insulation to the body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 381±15 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The input tolerance here is ±15 Ω (wider than the ±4 Ω of the column-type siblings) — judge against this range, not another model's. If the values are normal but the reading is unstable, work through installation, piping, junction box and supply first.
Where do the facts come from?
- Company product documentation: seven features, 6-wire colour code, 5 capacity steps, 19 technical parameters.
- Company drawing (one, in four parts): wiring diagram, side view, top view, capacity-grouped dimension table.
- Check against HY-1241: both single-point pages compared directly.
- Public technical literature: corner compensation in single-point cells, the effect of large platforms and impact loads on mounting, meaning of IP ratings.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?