⚠️ First, a conflict in the documentation: is the protection rating IP65 or IP67?
Short answer: the company documentation states it twice, and the two statements disagree. Both are transcribed here; neither is chosen for the customer.
| Where | What it says |
|---|---|
| Feature list | "Laser-welded seal, protection rating IP65" |
| Parameter table | "Protection: IP67" |
⚠️ This is not a difference between two models — it is a direct conflict inside one page. The practical difference sits in short-term immersion: IP67 tolerates it, IP65 does not. This page does not decide which one is right: where there is washdown, standing water or possible immersion, go by the shipping documentation and the nameplate on the unit, or call to confirm.
What is it, and how does it differ from the column type?
Short answer: a single-point cell — a machined body with cut-outs that deflect under load — intended for platform loading, such as bench scales and packing scales.
| Item | HY-1241 (single point) | HY-MTB / HY-MTB-M (column) |
|---|---|---|
| Load path | One point, body deflection | Column in compression, with spherical joint and support bolts |
| Corner errors | Compensated at the factory | Handled by mounting and corner calibration |
| Typical equipment | Bench scales, packing scales, process weighing | Packing scales, belt scales, batching |
| Capacity | 30 to 250 kg (5 steps) | 5 to 500 kg (10 steps) |
How is it wired?
Short answer: 4 wires (red / black / green / white). The product page text lists only those four; the wiring diagram on the same page additionally marks pale-yellow = Shield.
| Colour | Terminal | Function |
|---|---|---|
| Red | +input | + excitation |
| Black | −input | − excitation |
| Green | +output | + signal |
| White | −output | − signal |
| pale-yellow | Shield | Shield (drawing only; not listed in the text) |
⚠️ One documentation difference, transcribed without merging: the text lists four wires and does not mention a shield; the diagram marks one. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below. Note that the values differ from the column-type HY-MTB range.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.2 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤10 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 400±10 |
| Output resistance | Ω | 350±4 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 (⚠️ conflicts with IP65 in the feature list) |
| Cable length | m | 2 |
How do these numbers differ from the column-type HY-MTB?
| Parameter | HY-1241 (single point) | HY-MTB (column) |
|---|---|---|
| Sensitivity | 2±0.2 | 2±0.002 |
| Zero output | ≤10 | ≤1 |
| Operating range | -20 to +65 | -40 to +65 |
| Input resistance | 400±10 | 387±4 |
| Output resistance | 350±4 | 350±1 |
| Cable | 2 m | 3 m |
These are not the same parameter set under a different name: the sensitivity tolerance is 100× wider (±0.2 vs ±0.002), zero output is 10× larger, and the operating floor is 20 °C higher. This page lists the facts and does not decide "which is more accurate".
What are the dimensions?
Short answer: one dimensioned drawing. Units are not marked and none are added here.
| Direction | Values shown |
|---|---|
| Overall length | 174 |
| Height / width | 65 (side view height), 60 (top view width) |
| Hole spacings | 122, 19, 19, 7; holes 2-Φ8.5 |
The drawing also carries "15 (4 holes)" and "30 (2 holes)" callouts and the single-point over-load relief cut-outs.
What does it look like?
Short answer: the documentation contains four photographs and two drawings. This page shows the two drawings only: the nameplates on the photographs are legible, but they carry marks beyond the published product parameters, and the images carry a factory watermark, so they are not published here.
No usable product photograph is published for this model. Where an image and the written documentation disagree, the written documentation governs.
Where does it fit, and where does it not?
Short answer: the documented applications are bench scales, packing scales and process weighing. Anything involving washdown or standing water should have the protection-rating conflict above settled first.
- Fits: platform loading on bench and packing scales where corners must agree without on-site corner correction.
- Capacity limit: 250 kg maximum per cell on this model.
- ⚠️ Wet environments: the practical difference between IP65 and IP67 is short-term immersion. Where there is washdown, standing water or possible immersion, confirm the rating first — do not assume "IP67 must be fine".
- Temperature limit: -20 to +65 °C (narrower than the column type's -40 °C floor).
How can I tell whether the cell has failed?
Short answer: three measurements — input across red/black 400±10 Ω, output across green/white 350±4 Ω, insulation to the body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 400±10 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±4 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
If the values are normal but the reading is unstable, check installation, piping, junction box and supply first — see Selection & Resources.
Where do the facts come from?
- Company product documentation: features, 4-wire colour code, 5 capacity steps, 19 technical parameters.
- Company drawings: wiring diagram (4-wire plus shield), outline drawing.
- Numerical check against the HY-MTB range: the two product pages compared directly.
- Public technical literature: single-point versus column-type load paths, meaning of IP ratings.
The protection rating is stated twice in the company documentation with different values (IP65 / IP67); both are transcribed here and neither is chosen. For wet duties, go by the shipping documentation and the unit.
Still unsure which step fits?
Tell us: equipment type (bench / packing / process), platform size and load path, load per cell, whether there is washdown or standing water, the temperature range, and the cable run needed.