What is it, and where is it used?
Short answer: a column-type load cell that converts load into a millivolt signal for an indicator or transmitter. Its documented features are low mounting height and a stainless-steel hermetically welded body, which suit tight spaces that also need protection from moisture.
The company documentation names packing scales and belt scales, plus batching control in chemical, medical and food plants. What these have in common: small loads, high cycle counts, and washdown or dust on site.
Load cell vs weighing module: a load cell is the element; a module adds the load-bearing structure and mounting connections, and takes care of levelling and restraint. This page covers the former; see fixed weighing module for the latter.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below with their units and symbols, without conversion or rounding.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -40 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 387±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | 5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP68 |
| Cable length | m | 3 |
What do the key parameters mean on site?
| Parameter | What it determines |
|---|---|
| Safe 150% / ultimate 300% | Safe overload is what the cell can carry continuously; ultimate is a one-off limit. Neither is for routine overload — size so that each cell runs at about 70% of its rating (see sizing). |
| Input 387±4 Ω / output 350±1 Ω | The reference values for a field check: measure these two terminal pairs with a multimeter; a large deviation suggests an open circuit or moisture ingress. |
| Insulation 5000 MΩ (50 V DC) | The key indicator for moisture. Once insulation drops, readings drift or jump. |
| Excitation 5–15 V, max 20 V | The indicator supply must sit inside this window: too high heats the cell, too low leaves the signal weak. |
| Compensated -10 to +40 °C, operating -40 to +65 °C | Compensation is the range in which the cell was trimmed; operation is what it tolerates. Outside the compensated range, temperature effects grow — recalibrate for the duty if needed. |
| Cable 3 m | Supplied length, not spare slack. Longer runs need an extension, with the shield and joints handled properly. |
How is it wired?
Short answer: 6-wire, and the product page text matches the wiring diagram wire for wire.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| pale-yellow | shield | Shield |
The sense pair compensates excitation loss over long cable runs. Earth the shield at one end only; both ends create a ground loop.
What are the dimensions?
Short answer: the company documentation provides two dimensioned drawings, one for MTB5-10kg and one for MTB20-300kg. No drawing is provided for the 500 kg step. Units are not marked on the drawings and none are added here.
| Drawing | Covers | Values shown |
|---|---|---|
| Drawing 2 | MTB5-10kg (5 kg, 10 kg) | Length 123, 82, 45, 26; end view diameter Φ35, height 20; hole callouts; spacings 18 and 10 |
| Drawing 3 | MTB20-300kg (20 to 300 kg) | Length 123, 82, 45, 26, 42; end view diameter Φ36, height 20; holes 2-Φ8.2 and Φ8.2; spacings 18 and 10 |
| None | 500 kg | No drawing supplied; not inferred here |
Note: the company product page also carries a three-row dimension table whose diameter symbol was corrupted during capture (e.g. "?45", "?8.2"). This page does not use the corrupted characters; it relies on the readable drawing callouts above.
What does it look like?
Short answer: the documentation contains two photographs and three drawings. This page shows the three drawings only: the nameplates on the two photographs, read at high magnification, contain items not published here by this site's image policy.
No usable product photographs are published for this model; the two supplied photographs were not used. Where an image and the written documentation disagree, the written documentation governs.
Where does it fit, and where does it not?
Short answer: the documented applications are packing scales, belt scales and batching control in chemical, medical and food plants, and a high-temperature version up to 150 °C is available. Anything beyond those is not inferred here.
- Fits: small loads, high cycle counts, dusty or washdown sites; tight spaces thanks to the low mounting height.
- High temperature: a version up to 150 °C is documented — confirm model and duty; no other parameters for that version are published here.
- Not covered: aggressive media, operation outside -40 to +65 °C, or continuous operation above the safe overload.
- Remember: a load cell is an element — the load path, restraint and levelling must come from the structure around it.
How can I tell whether the cell has failed?
Short answer: measure three values and compare with the table above — input 387±4 Ω, output 350±1 Ω, and insulation in the MΩ range.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off, measure resistance across excitation (green / black) | Around 387±4 Ω; open circuit or large deviation means a broken internal wire |
| 2 | Measure across signal (white / red) | Around 350±1 Ω |
| 3 | Measure insulation between conductors and body | MΩ range; a clear drop means moisture or a damaged seal |
If the values are normal but the reading is unstable, work through the installation, piping, junction box and supply checks on the Selection & Resources page before replacing the cell.
Where do the facts come from?
- Company product documentation: main features (low mounting height, stainless steel, IP68, high-temperature version 150 °C, packing and belt scales), 6-wire colour code, 10 capacity steps, 19 technical parameters.
- Company drawings: wiring diagram, MTB5-10kg and MTB20-300kg dimension drawings.
- Public technical literature: load cell selection and installation requirements, the role of sense wires on long runs, general vessel-weighing criteria.
Values are transcribed from company documentation. The documentation contains one protection-type wording carried over from earlier material; this page does not reproduce that rating and makes no claim based on it.
Still unsure which step fits?
Tell us: equipment type (packing scale / belt scale / batching scale), load per cell, mounting and space, material and site conditions (dust, washdown, temperature), whether a high-temperature or explosion-proof version is needed, and the distance to the indicator.