First published · Chinese version: HY-UW 称重模块

You are here: Home > Products > HY-UW

HY-UW Weighing Module: 5 kg to 500 kg, 10 Steps, Stainless Steel, IP68

HY-UW is a stainless-steel bellows-type weighing module. It combines the load cell, top plate, base plate, support column and support bolts into one unit that mounts under the feet or brackets of a vessel, tank or reactor, and turns weight into an electrical signal for the weight indicator.

If you are unsure of the capacity:

+86 183 5123 8137

Short answer: HY-UW covers 5, 10, 20, 30, 50, 75, 100, 200, 300 and 500 kg in 10 steps; it uses a stainless-steel hermetically sealed load cell with IP68 protection; it is a 6-wire module with a spherical joint and support bolts. Two things to know up front: (1) the company documentation for HY-UW, HY-UW-M, HY-UWS and HY-UWS-M is identical word for word on features, wiring and capacity, and states no difference between them; (2) no dimension or wiring drawings were provided for this model, so this page does not publish a wiring diagram or dimensions.

What is a weighing module and where does it mount?

Short answer: a weighing module is a structural accessory for a load cell, made of a top plate, a base plate, the load cell, a load-bearing column and support bolts. It mounts under the vessel feet — or on the vessel body for tanks, silos and reactors — and the vessel becomes a weighing system once modules and an indicator are fitted.

On this model the physical form is: a top plate with mounting holes, a bellows-shaped body (the housing of the hermetically sealed load cell), a base plate with mounting holes, and a cable leaving from the side. Support bolts sit between top and base plate, and a braided copper strap bonds the two.

All modules of one system must sit in the same plane; the foundation must be stiff enough and the mounting faces must be adjustable to level.

What is the difference between HY-UW and the other three models?

Short answer: the company documentation for HY-UW, HY-UW-M, HY-UWS and HY-UWS-M is identical word for word on main features, wiring and capacity, and states no difference. Order by the exact model suffix and confirm against the shipping documentation; do not infer a difference from the suffix.

Shared documentation across the four models
Item Documented value Across the four models
Main features (6 items) Stainless-steel hermetically sealed load cell with IP68 for harsh environments; spherical joint keeping the module vertical; support bolts against tipping; simple and quick installation; easy maintenance; intended for batching control on small and medium reactors in chemical, pharmaceutical and food plants Identical
Wiring (6 wires) Green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense Identical
Capacity (10 steps) 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kg Identical

What are the specifications, and where does each value come from?

HY-UW specifications and what each value determines
Parameter Value (source) What it determines
Model HY-UW Company documentation Ordering and quotation reference. Always quote the full suffix.
Category Weighing module Company documentation It is a structural part plus a load cell; capacity, material and mounting dimensions all matter together.
Capacity steps 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kg Company documentation The maximum load per module. Total system capacity is rated capacity × number of modules, so calculate the load first, then take the next step up.
Material and sealing Stainless-steel hermetically sealed load cell Company documentation Washdown and damp environments are within reach; for aggressive media or high temperature the documentation gives no rating, so check against the actual conditions.
Protection IP68 Company documentation Applies to the sealed module body. Cable entries and the junction box must meet the same standard — changing the module alone does not fix water ingress in the junction box.
Structural features Spherical joint keeping the module vertical; support bolts against tipping; quick installation; easy maintenance Company documentation The spherical joint absorbs small angular errors of the mounting face; the support bolts prevent the vessel from tipping. Both are checked after installation.
Wiring system 6-wire: excitation +/−, signal +/−, sense +/− Company documentation The two sense wires compensate excitation loss over long cable runs; they matter when the cable to the indicator is long. Terminate them as shown in the shipping documentation.
Colour code Green +excitation, black −excitation, white +signal, red −signal, yellow +sense, blue −sense Company documentation Field wiring reference. A second code exists in the company installation instructions (red = excitation +), and the nameplate on the unit may show either. Wire to the nameplate of the unit in hand; do not copy colours across batches.
Documented applications Batching control on small and medium reactors in chemical, pharmaceutical and food plants Company documentation An industry direction, not a blanket suitability claim. Check vessel weight, product weight, number of feet and site conditions for each case.

Nine parameters are listed. Accuracy and long-term stability are not stated in the company documentation for this model, so they are not published here. IP68 is this model's own documented value.

Why are there two wiring colour codes?

Short answer: the company product page gives the green = +excitation set; the installation instructions, and the nameplate on some units, give a red = EXC+ set. Both appear in the company documentation set, so both are reproduced here and neither overrides the other.

Two wiring definitions, as documented
Source Excitation Signal Sense / shield
Product page Green = +, black = − White = +, red = − Yellow = +sense, blue = −sense
Installation instructions / some nameplates +EXC (red), −EXC (black) +SIG (green), −SIG (white) Shield

Note that the colour-to-signal mapping is reversed between the two: the same green wire is +excitation in one set and +signal in the other. This is why colours must not be copied from another model or another batch.

How do I choose the capacity step?

Short answer: apply the industry formula, then take the next step up.

dead load + live load ≤ rated capacity × number of modules × 70%

The 70% factor is the usual industry margin and is quoted from public technical literature. Take one module per support foot (3 feet, 3 modules; 4 feet, 4 modules). Worked examples are on the Selection & Resources page.

Are drawings available for this model?

Short answer: no. The company documentation provides no dimension drawing and no wiring diagram for HY-UW. This page therefore shows neither, and does not borrow drawings from other models in the family — their dimension steps are different, so a borrowed drawing would give wrong values.

For dimensions, use the shipping documentation of the actual unit.

Where does it fit, and where does it not?

What does it look like?

HY-UW weighing module: stainless top plate with mounting holes, bellows-type load cell body, base plate with mounting holes, cable leaving from the side, support bolt and braided copper strap
Photo 1 — front view: top plate, bellows body, base plate and side cable; the nameplate on the body shows the wiring code. Company documentation.
HY-UW weighing module from another angle: top plate mounting holes, bellows body, support bolt and nut, base plate holes and side cable
Photo 2 — another angle: top plate holes, bellows body, support bolt and nut, base plate holes and side cable. Company documentation.
HY-UW weighing module, side view of the load cell body and the nameplate showing the wiring code
Photo 3 — side view of the load cell body and its wiring nameplate. Company documentation.

All three photographs are company product images used unaltered. Where an image and the written documentation disagree, the written documentation governs.

How is it installed and wired?

Installation requirements
Item Requirement Source
Verticality Module axis within 1.5° of the perpendicular to the mounting plate; correct with shims if it is out Company installation instructions
Frame stiffness Frame and base plate must be stiff enough; stiffness of 1/1000 is required Company installation instructions
Mounting faces Top and bottom faces fully in contact, flat, and evenly loaded Company installation instructions
Levelling After mounting three or four modules, rock the top plate by hand; if it moves, shim until it does not Company installation instructions
Bolting Tighten diagonally, pre-tighten first, then torque to specification Company installation instructions
Welding No welding current may pass through the load cell; earth the work piece so the current path does not cross the cell Company installation instructions
Cable Do not stretch the cable; protect it from damage Company installation instructions
Handling Never lift the module by its cable; avoid knocks and drops Company installation instructions
Capacity Check capacity before mounting; never mix capacities in one system Company installation instructions
Wiring check Wire to the diagram, complete the run to the indicator, re-check every terminal, verify supply voltage Company installation instructions
Bracket skew Upper bracket and base bracket skew to horizontal must not exceed 0.5° Public technical literature
Foundation Foundation deflection below 3 mm; concrete foundation preferred Public technical literature
Piping Run connected pipes horizontally, support them away from the vessel, use flexible connections Public technical literature
Independent load path The vessel must be carried only by the modules; no mechanical tie to unsupported structures Public technical literature
Earthing One independent earth per module Public technical literature
Calibration Provide test-weight positions and jacking points at the design stage; calibrate after installation Public technical literature

Where do the facts come from?

Values are transcribed from company documentation. Final specifications are confirmed against the order and application.

Still unsure which step fits?

Tell us: vessel dead weight, product weight, number of support feet, product characteristics, site conditions, and whether it is a new build or a retrofit.

Call +86 183 5123 8137