Which model is which, and how do I match the part number?
Short answer: all four are small-capacity bellows-type weighing modules with the same documented parameters, and each model has its own photograph and its own model page. Ordering, enquiries and shipping documentation are all keyed to the model, so always quote the full suffix.
Each photograph shows the model it is captioned with; the nameplate visible on the body carries the wiring code only. All four share the same physical form: a top plate with mounting holes, a bellows body (the housing of the hermetically sealed load cell), a base plate with mounting holes and a cable leaving from the side, with support bolts between top and base plate.
What does the company documentation say about the differences between the four?
Short answer: the documentation for the four models is identical word for word on main features, wiring and capacity, and states no difference between them. The table below is that side-by-side check: the right-hand column says "identical" because that is what the four documents say — nothing has been left out on this page.
| Item | Text in the company documentation (all four) | Across the four models |
|---|---|---|
| Main features (6 items) | Stainless-steel hermetically sealed load cell with IP68 protection for use in harsh environments; spherical joint that keeps the module in a vertical weighing position; support bolts that prevent the equipment from tipping; simple, quick installation; easy maintenance, saving downtime; intended for batching control on small and medium reactors in chemical, pharmaceutical, food and similar plantsCompany documentation (transcribed) | HY-UW / HY-UW-M / HY-UWS / HY-UWS-M: all four identicalCompany documentation |
| Wiring (6 wires) | Green = +excitation; black = −excitation; white = +signal; red = −signal; yellow = +sense; blue = −senseCompany documentation (transcribed) | All four identicalCompany documentation |
| Capacity (10 steps) | 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kgCompany documentation (transcribed) | All four identicalCompany documentation |
So why are there four models at all?
- Each model has its own photograph: the images under a model show that unit, and they are not interchangeable.
- Ordering and shipping documentation are keyed to the model: contracts, drawings, packing lists and shipping documents carry the exact model, which is why each model has its own page.
- The documentation states no difference, so none is guessed here: there is no wording such as "upgraded version" or "one extra structural part", and none is added. Where a difference has to be pinned down, check the shipping documentation of the model in hand.
What do the four models share, and where does each value come from?
Short answer: because the three documented items are identical word for word, the parameters of the four models can be merged into one table, and the table applies to all four. Values are transcribed, not converted or merged, and no step or item missing from the documentation has been added. None of the four models has a drawing in the company documentation, so the table has no wiring schematic row and no outline dimension row.
| Parameter | Value (with source) | What this parameter determines |
|---|---|---|
| Model | HY-UW / HY-UW-M / HY-UWS / HY-UWS-M (four models)Company documentation | The ordering and enquiry reference. The four share their parameters and the documentation states no difference, so always quote the full suffix and check against the shipping documentation of that model. |
| Category | Weighing moduleCompany documentation | It is a structural part plus a load cell, so capacity, material and mounting dimensions have to be looked at together, not the load cell alone. |
| Capacity steps | 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kgCompany documentation (10 steps, transcribed) | The maximum load one module carries. System capacity = rated capacity per module × number of modules, so calculate from vessel dead weight and product weight first, then take the next step up. |
| Material and sealing | Stainless-steel hermetically sealed load cellCompany documentation | It decides where the module can be used: the welded-seal stainless housing is one precondition for damp, washdown areas. For more aggressive media or high temperature the documentation gives no rating, so check against the actual conditions. |
| Protection | IP68Company documentation | Applies to the sealed module body. Once installed, check the cable entry and the junction box to the same standard as well — changing the module alone does not fix water getting into the junction box. |
| Structural features | Spherical joint that keeps the module in a vertical weighing position; support bolts that prevent tipping; simple, quick installation; easy maintenance, saving downtimeCompany documentation | The spherical joint absorbs small angular errors of the mounting face and keeps the load path vertical; the support bolts decide whether the equipment can tip. |
| Wiring system | 6-wire (+excitation / −excitation / +signal / −signal / +sense / −sense)Company documentation | 6-wire has two terminals more than 4-wire: the sense pair compensates excitation loss over long cable runs, so it matters when the cable from the module to the indicator is long. (Principle quoted from public technical literature.) |
| Colour code | Green = +excitation; black = −excitation; white = +signal; red = −signal; yellow = +sense; blue = −sense (6 wires)Company documentation | The field wiring reference. A second set, written with English terminal names, also appears on the nameplate of some units and in the company installation instructions; both are reproduced below and neither is chosen for the customer here. The shipping documentation and the wiring diagram of the unit in hand govern. |
| Documented applications | Batching control on small and medium reactors in chemical, pharmaceutical, food and similar plantsCompany documentation (transcribed) | This row gives an industry direction, not a claim that any application in those industries fits; each unit still has to be checked against vessel dead weight, product weight, number of support feet and site conditions. |
Nine rows, all of them valid for the four models. Every explanation added on this page is marked with its source; items the company documentation does not give (combined accuracy, long-term stability, material grade, temperature range, corrosion rating) are left out here, not inferred.
Why are there two wiring colour codes for the same module?
Short answer: the company product documentation gives the green = +excitation set (6 wires), while the nameplate on the photographs and the company installation instructions give a red = EXC+ set. Both appear within the company documentation set, so both are reproduced here, neither is merged, and neither is chosen for the customer.
| Source | Excitation | Signal | Sense / shield |
|---|---|---|---|
| Company product documentation (product page text) | Green = +excitation; black = −excitation | White = +signal; red = −signal | Yellow = +sense; blue = −sense (one nameplate also marks "yellow (long) = shield") |
| Nameplate on some batches, and company installation instructions | +EXC (red) positive excitation; −EXC (black) negative excitation | +SIG (green) positive signal; −SIG (white) negative signal | Shield / braided shield |
Note that the colour-to-signal mapping is reversed between the two sets: the same green wire is "+excitation" in one set and "+signal" in the other. So colours must not be copied across batches, and a wiring diagram from another model must not be used for installation.
In practice: (1) read the nameplate of the unit in hand first and see which set it states; (2) wire to that nameplate and to the shipping documentation; (3) after wiring, re-check every terminal and verify that the supply voltage is correct. This page does not decide which set is right for a given unit — that needs the unit itself.
If all four share the same parameters, how is the model chosen?
Short answer: the four documented sets are the same, so selection comes down to three things — capacity per module (calculated from vessel dead weight and product weight, then the next step up), number of modules (taken from the number of support feet), and installation and environment (damp or washdown areas matched by IP68, with the cable entry and the junction box checked at the same time).
dead load + live load ≤ rated capacity × number of modules × 70%
| Your case | How to take the value | Basis |
|---|---|---|
| The vessel already has its support feet | One module per support foot: 3 feet, 3 modules; 4 feet, 4 modules | Public technical literature |
| The calculated capacity falls between two steps | Take the next step up, never the one below | Public technical literature |
| How many to buy, and how to arrange them | Use one fixed module and one semi-floating module per system and fill the rest with floating modules; sets are usually three or four modules | Public technical literature |
| Damp area, washdown needed | This series has a stainless-steel hermetically sealed load cell and IP68 protection; check the cable entry and the junction box on the same principle | Values from the company documentation |
| Replacing an old module without changing the base | None of the four models has a dimension drawing in the company documentation: measure the existing mounting holes and the available height first, then check against the shipping documentation and the unit | No drawing in the company documentation |
Worked examples and the four working conditions are on the Selection & Resources page; each model's own parameters and photographs are in the four figures above. The general installation and wiring requirements (verticality 1.5°, bracket skew 0.5°, foundation deflection below 3 mm, no welding current through the cell, flexible pipe connections) are on the four model pages and are not repeated here.
Where do the facts on this page come from?
- Company product documentation (the product page text for HY-UW, HY-UW-M, HY-UWS and HY-UWS-M): model, category, capacity steps, stainless-steel hermetically sealed load cell and IP68, structural features, 6-wire connection and colour code, documented applications. The four bodies of text are identical word for word.
- Company installation instructions: the second wiring definition (red = excitation +, stated for the 0–500 kg steps of HY-UW and HY-UWS), plus the make-up of a module and of a weighing system, the foundation requirements and the module-count rule.
- Photographs of the four units: one per model, used to match the part number; the nameplate on the body carries the wiring code.
- Public technical literature (for example "Selection and installation of weighing modules"): module construction and make-up, sizing and module count, static and dynamic load criteria, piping and calibration requirements.
Values in the tables are transcribed from company documentation and are not a commitment for a specific project; final specifications are confirmed against the working conditions. None of the four models has a drawing in the company documentation, so the wiring schematic and the outline dimensions are governed by the shipping documentation.
Still unsure which model, or which capacity step?
Give us these in one go and we will answer with a model and a capacity step: vessel dead weight, product weight, number and layout of the support feet, product name and characteristics, site conditions, and whether it is a new build or a retrofit. When you quote a model, quote the full suffix.
- HY-UW weighing module — parameters, photographs and the no-drawing note →
- HY-UW-M weighing module — model page →
- HY-UWS weighing module — model page →
- HY-UWS-M weighing module — model page →
- All models, grouped by capacity →
- How to size a weighing module — formula, worked examples, installation checks →
- FAQ: readings that will not settle, drift, calibration →