HY-UW-M Weighing Module: 5 kg to 500 kg, 10 Steps, Stainless Steel, IP68

HY-UW-M is a bellows-type stainless-steel weighing module. The module makes the load cell, the top plate, the base plate and the support column one unit; it mounts under the feet or brackets of a vessel, tank or silo, turns weight into an electrical signal for the weight indicator, and is used for batching control.

Cannot tell which capacity step you need? Describe the application:

+86 183 5123 8137

One tap to call directly - no form to fill in.

Short answer: HY-UW-M covers 5, 10, 20, 30, 50, 75, 100, 200, 300 and 500 kg in 10 steps; the load cell is stainless steel, hermetically sealed, with IP68 protection; wiring is 6-wire; outline dimensions are in the two dimension drawings below (one side section, one end view), and those drawings carry no unit, so the figures are transcribed as printed. Every value is the company's own product documentation, and every row of the table below gives its source.

Values are transcribed from company product documentation; each field in the table below carries its own source.

This model belongs to the HY-UW series - the four models share one set of parameters, and the company documentation states no difference between them: how the four differ, and what they share →

What is a weighing module, and where does it mount?

Short answer: a weighing module is a practical structural accessory for a load cell, made of a top plate, base plate, load cell, load-bearing column and support bolts. (Taken from public technical literature, "Selection and Installation of Weighing Modules".)

This model is a bellows-type module: a top mounting plate, a bellows-shaped hermetically sealed load cell, a base plate and support bolts. A nameplate on the side of the load cell shows the wiring definition, and the cable leaves from the side. (Form as shown in the photographs below; structure taken from the company installation instructions.)

The module usually mounts on the lower part of the scale body - feet, platform - and can also mount on the upper part, at the waist of a reactor, tank or hopper. All modules of one weighing system must sit in the same horizontal plane. (Taken from public technical literature.)

The difference from buying a bare load cell: the module makes the cell, the force path and the mounting connection one part. Bolt it under a foot and it carries load; a bare cell leaves you to solve the load point, the restraints and the mounting face yourself. (Taken from public technical literature.)

Where does it sit in a weighing system?

A weighing control system is usually made of a weight indicator, a junction box, the weighing modules and cable: the modules carry the load, the junction box sums the signals of several modules, and the indicator displays and controls. (Taken from the company installation instructions.)

The module connects easily to conveyors, platforms, vertical tanks, tanks and hoppers to build a weighing system. A system usually uses 3 to 6 sets (up to 12) of modules; the foundation must meet the stiffness requirement and be in one horizontal plane, or be adjustable into one, so that every module carries an even share. (Taken from the company installation instructions.)

What are the specifications, and where does each value come from?

Short answer: the table lists the HY-UW-M values row by row with their source, and the right-hand column translates each value into what it decides at selection and installation time. Values are transcribed - no conversion, no merging, and no capacity step or item added that the documentation does not give.

HY-UW-M specifications, sources, and what each value determines
Parameter Value (with source) What it determines
Model HY-UW-M Company documentation The ordering reference. Other models of the same series end differently, and the wiring definition changes with the suffix (see the colour code row below), so give the full suffix.
Category Weighing module Company documentation It is a structural part plus a load cell, so capacity, material and mounting dimensions are judged together - load cell data alone is not enough.
Capacity steps 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kg Company documentation (10 steps, transcribed word for word) The load limit per module. Total system capacity is rated capacity × number of modules, so work out the load from vessel dead weight and product weight first, then take the next step up.
Material and sealing Stainless-steel, hermetically sealed load cell Company documentation Sets the environment it can go into: a welded-sealed stainless housing is one precondition for damp shops that need washdown. For aggressive media or high temperature the company documentation gives no rating, so that has to be checked against the site conditions.
Protection IP68 Company documentation The company documentation gives IP68 for the sealed module body. On site, check the cable entry and the junction box sealing at the same time - a new module does not fix water that comes in through the junction box.
Structural features Spherical joint keeps the module vertical under load; support bolts prevent the equipment from tipping; simple, quick mounting; easy maintenance, less downtime Company documentation The spherical joint absorbs small angular errors of the mounting face and keeps the module weighing vertically; the support bolts stop the equipment tipping. In practice, check verticality and the M10 clearance against the installation table below once the module is in place.
Wiring system 6-wire (+excitation / -excitation / +signal / -signal / +sense / -sense) Company documentation 6-wire adds a +sense / -sense pair over 4-wire. Per public technical literature, those two wires allow for excitation loss over a long cable run, so they matter when the cable from module to indicator (or junction box) is long. Whether to use them, and how to terminate them, follows the shipping documentation and the wiring diagram of the actual unit.
Colour code Green +excitation; black -excitation; white +signal; red -signal; yellow +sense; blue -sense Company documentation (agrees with the wiring schematic) The field wiring reference. One difference has to be stated plainly: the company installation instructions define HY-UW / HY-UWS (0-500 kg) as red = excitation+, black = excitation-, green = signal+, white = signal-, silver = shield, and the load cell nameplate in this model's photograph also shows +EXC(Red) / +SIG(Green) - not the same set as this row. Before installation, follow the shipping documentation and the wiring diagram of the actual unit; do not copy colours across batches.
Wiring schematic 6-wire + shield: green = excitation+; yellow = sense+; white = signal+; black = excitation-; blue = sense-; red = signal-; pale yellow = shield Company product specification drawings (figure 3 below) This carries one line more than the text above: the shield is drawn as a separate conductor. How the shield is terminated follows the shipping documentation and the wiring diagram of the actual unit.
Outline dimensions Two dimension drawings (one side section, one end view): side section marks 58, 42, 2-M12, 76, 78, 132, 49, 19, 4-Φ10.5; end view marks 102, 79, 13, 60, 18. The drawings carry no unit, so the figures are transcribed as printed; neither drawing marks a capacity step Company product specification drawings (figures 4 and 5 below) Dimensions decide where the feet land and where the foundation holes go. Before replacing an old module or casting a new foundation, measure the existing hole positions and the available height, then check them against the two drawings on this page. Neither drawing is tied to a capacity step, so do not assign one.
Documented applications Batching control on small and medium reactors in chemical, pharmaceutical and food plants Company documentation An industry direction from the documentation, not a claim that any plant in those industries fits. For a given vessel, check dead weight, product weight, number of feet and site conditions.

Values and wording in the table are transcribed from company documentation. Every explanation added on this page is sourced separately and comes from public technical literature, not from a company commitment.

Which value fits which working condition?

Short answer: check the capacity per module with the rule below, then take the next step up; take the number of modules from the number of actual support points. (Rule taken from public technical literature.)

dead load + live load ≤ rated capacity × number of modules × 70%

In words: the dead load plus the live load must not exceed 70% of rated capacity × number of modules. Written out so it can be copied, sent to a work group or printed. Worked examples are on the Selection & Resources page.

Case by case

HY-UW-M: which capacity step and how many modules, by case
Your case What to take Basis
The vessel already has support feet One module per foot: 3 feet, 3 modules; 4 feet, 4 modules Public technical literature
New vessel, standing vertical, cylindrical Three-point support is the more stable layout; where wind, sway or vibration counts, four-point support is preferable Public technical literature
The calculated capacity lands between two steps Take the next step up, never down Public technical literature
How many modules per set, and how to arrange them One fixed, one semi-floating, the rest floating; sets are usually three or four modules Public technical literature
Damp site that needs washdown This model has a stainless-steel hermetically sealed load cell and IP68; check cable entry and junction box to the same sealing standard Parameters from company documentation
6 wires to land, including one sense pair Match all six wire positions to the junction box and the indicator terminals; the colour code is in the table above Wire definition from company documentation; practice from company installation instructions
Replacing an old module without touching the foundation Measure the existing hole positions and the available height first, then check them against the two dimension drawings on this page Dimensions from company product specification drawings

Where does it fit, and where does it not?

Short answer: what the company documentation and the sourced content on this page support is batching control on small and medium reactors in chemical, pharmaceutical and food plants, plus the damp, washdown environments that the hermetically sealed stainless load cell and IP68 cover. Items the company documentation does not give - accuracy grade, material grade, temperature range, corrosion resistance class - are not inferred here, and no conclusion is drawn on a customer's behalf.

Fits (documented)

Limits and exclusions (read these too)

What does it look like, and how are the dimensions marked?

Short answer: the first 2 images are photographs of this model; the other 5 are company product specification drawings - module rectangular layout, module radial layout, wiring schematic, and two dimension drawings (one side section, one end view). All images are local files; the page loads nothing external.

HY-UW-M weighing module, front view: top mounting plate with mounting holes, bellows hermetically sealed load cell in the middle, base plate below, support and restraint bolts, cable leaving from the side
HY-UW-M photograph, front view: top mounting plate above, bellows hermetically sealed load cell in the middle, base plate below; support and restraint bolts and the side cable are visible, and the load cell carries a wiring nameplate on its side. Company documentation.
HY-UW-M weighing module from another angle: base plate mounting holes and support bolt positions, cable leaving from the side
HY-UW-M photograph, another angle: the base plate mounting holes and the support bolt positions are visible. Company documentation.
HY-UW-M specification drawing: rectangular module layout, marking the fixed, semi-floating and floating structures
Specification figure 1 - rectangular module layout: fixed, semi-floating and floating structures marked. Company product specification drawings.
HY-UW-M specification drawing: radial module layout, marking three-point 120 degrees and four-point 90 degrees layouts
Specification figure 2 - radial module layout: three-point at 120° and four-point at 90°. Company product specification drawings.
HY-UW-M specification drawing: 6-wire plus shield wiring schematic, with colours for excitation, sense, signal and shield
Specification figure 3 - wiring schematic: 6-wire + shield, green = excitation+, yellow = sense+, white = signal+, black = excitation-, blue = sense-, red = signal-, pale yellow = shield. Company product specification drawings.
HY-UW-M specification drawing: dimension drawing, side section, marking 58, 42, 2-M12, 76, 78, 132, 49, 19 and 4-Φ10.5, and indicating the earth point
Specification figure 4 - dimension drawing, side section: marks 58, 42, 2-M12, 76, 78, 132, 49, 19 and 4-Φ10.5, and indicates the earth conductor position; the drawing carries no unit, so the figures are transcribed as printed; it marks no capacity step. Company product specification drawings.
HY-UW-M specification drawing: dimension drawing, end view, marking 102, 79, 13, 60 and 18
Specification figure 5 - dimension drawing, end view: marks 102, 79, 13, 60 and 18; the drawing carries no unit, so the figures are transcribed as printed; it marks no capacity step. Company product specification drawings.

Image note: the 2 photographs and 5 specification drawings are company product images used unaltered; the specification drawings carry a light graphic watermark.

What matters during installation and wiring?

Short answer: four things decide whether a module works - base stiffness and level, the verticality of the module against its mounting face, the restraint bolt clearance, and whether external force paths such as pipes and welding have been removed. Each row below gives a figure or an action that can be checked.

Installation and wiring requirements, with a source per row
Item Requirement Source
Verticality Every module axis within 1.5° of the perpendicular to the mounting plate; where it is out of flat or out of vertical, correct it with shims Company installation instructions
Frame and base plate stiffness The frame and base plate carrying the modules must be rigid enough; stiffness of 1/1000 is required Company installation instructions
M10 restraint bolt clearance After mounting and wiring, adjust the M10 cross restraint bolts up and down so that the gap between each bolt head and the top face of the top plate is 2 mm all round; the M10 restraint bolt must not touch the top plate Company installation instructions
Levelling With 3 or 4 modules mounted under the vessel feet or brackets, rock the top plate of each module by hand; if it moves, the module is not level - shim with steel plate until it no longer moves Company installation instructions
Mounting faces Top and bottom mounting faces of every module reliably connected, with no unevenness, and loaded evenly Company installation instructions
Bolt tightening Tighten all bolts diagonally, pre-tighten first, then torque to specification Company installation instructions
Fixing method After levelling the module: (1) bolted - top plate to the vessel foot or bracket, base plate to the steel structure or floor; (2) welded - top plate welded to the vessel foot, base plate welded to the steel structure (note: no current through the module during welding) Company installation instructions
Welding No other current (arc welding and the like) may pass through the load cell, or the cell will be damaged Company installation instructions
Cable Do not pull the cable tight, so that no tension reaches it and spoils the electrical behaviour; protect the cable and keep it free of cuts and abrasion Company installation instructions
Handling and unpacking Never lift the module by its cable when taking it out of the packaging; avoid knocks and prevent the module from falling from height Company installation instructions
Module capacity Check module capacity before mounting; never use modules of different capacity in one weighing system Company installation instructions
Summing cable Set the summing cable length from the site layout; the other end enters the junction box and lands on the terminals of the summing board Company installation instructions
Wiring and re-check Wire the load cell cables to the junction box as the wiring diagram requires; run the junction box to the display and control indicator the same way; re-check every connection; check that the supply voltage is normal Company installation instructions
Bracket skew The angle between the upper bracket and the horizontal must not exceed 0.5°; the angle caused by twisting or skew of the base bracket must not exceed 0.5° Public technical literature
Foundation The foundation (or floor) carrying the vessel must have enough bearing capacity and stiffness, with foundation deflection below 3 mm; a concrete foundation is the better choice Public technical literature
Piping Run all pipes connected to the vessel horizontally so they do not hang the vessel; put the first pipe support as far from the vessel as possible; use flexible connections where possible Public technical literature
Independent load path The vessel must act on the load cells alone and have no mechanical tie to any part the cells do not carry Public technical literature
Earthing Each module gets its own independent earth Public technical literature
Service access Install the modules where maintenance can be reached Public technical literature
Calibration provisions Allow for test weight positions and for jacking points used during installation and service at the design stage of the vessel; calibrate after installation Public technical literature

The table collects the general requirements of public installation literature and of the company installation instructions for this type of module. Site practice and the final judgement follow the shipping documentation and the actual conditions. Calibration steps at the indicator are covered in the FAQ.

Where do the facts come from?

Values in the table are the company's own product documentation and are not a commitment for a specific project; final specifications are checked against the application. First published on this page: 2026-10-24.

Still unsure which capacity step fits?

Tell us these once and we can suggest a capacity step and a module count: vessel dead weight, product weight, number of support feet and their layout, product name and characteristics, site conditions, and whether it is a new build or a retrofit.