What is HY-UWS-M, and where does it mount?
Short answer: a weighing module is a structural accessory for a load cell, made of a top plate, a base plate, the load cell, a load-bearing column and support bolts. (Quoted from the public technical literature "Sizing and installation of weighing modules".)
On this model the physical form is: a top plate with mounting holes on top, a metal bellows in the middle (the housing of the hermetically sealed stainless load cell), a base plate with mounting holes below, and a cable leaving from the side. Support bolts sit between the top plate and the base plate, and a braided copper strap bonds the top plate to the base. (Form as shown in the photographs below; the structural description is from the company installation instructions.)
The module usually mounts at the bottom of the scale body — feet, a platform and the like — and can also mount on the upper part (the waist of a reactor, tank or hopper). All modules of one weighing system must sit in the same horizontal plane. (Quoted from the public technical literature "Sizing and installation of weighing modules".)
The difference from buying a bare load cell is here: a module makes the cell, the load-bearing structure and the mounting connection into one part, so it takes load as soon as it is bolted to the feet. A bare cell needs its own load point, restraint and mounting face worked out separately. (Quoted from the public technical literature "Sizing and installation of weighing modules".)
Where does it sit in a weighing system?
A weighing control system usually consists of the display and control indicator, the junction box, the weighing modules and the cables. The modules carry the load, the junction box sums the signals of several modules, and the indicator displays and controls. (Quoted from the company installation instructions.)
A module connects easily to mechanical equipment of any shape — conveyors, platforms, vertical tanks, vessels, hoppers — to form a weighing control system. A system usually uses 3 to 6 modules (12 at most). The foundation the modules stand on must meet the stiffness requirement and be level, or adjustable to one level, so that each module carries an even share of the load. (Quoted from the company installation instructions.)
What is the difference between HY-UWS-M and HY-UW, HY-UW-M and HY-UWS?
Short answer: in the company documentation the four models HY-UWS-M, HY-UW, HY-UW-M and HY-UWS are identical word for word on main features, wiring and capacity, and the documentation states no difference between them. Order by the exact model and confirm against the shipping documentation of the unit; do not infer a difference from the model suffix.
Below are those three items side by side. The left column is the item, the second column is the documented text for this model, and the three columns to the right are the result for the other three models.
| Item | HY-UWS-M (this model, documented text) | HY-UW | HY-UW-M | HY-UWS |
|---|---|---|---|---|
| Main features (6 items) | Stainless-steel hermetically sealed load cell with IP68, usable in harsh environments; spherical joint keeping the module vertical under load; support bolts against tipping; simple and quick installation; easy maintenance, saving downtime; intended for batching control on small and medium reactors in chemical, pharmaceutical and food plants Company documentation (transcribed) | Identical Company documentation | Identical Company documentation | Identical Company documentation |
| Wiring (6 wires) | Green = +excitation; black = −excitation; white = +signal; red = −signal; yellow = +sense; blue = −sense Company documentation (transcribed) | Identical Company documentation | Identical Company documentation | Identical Company documentation |
| Capacity (10 steps) | 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kg Company documentation (transcribed) | Identical Company documentation | Identical Company documentation | Identical Company documentation |
The table checks these three items only. All four columns say "identical" because the four documents carry the same text on these three items — this page has not left anything out.
Why does this model have a page of its own?
- This model has three photographs of its own unit: the assembled form and the nameplate. A photograph of another model cannot stand in for this one.
- When models differ by one letter or a suffix, the first question is what differs: this page answers it directly and gives an action that can be carried out (check the model against the shipping documentation), rather than leaving it to guesswork.
- Each model is a separate model: ordering, enquiries and shipping documentation are all keyed to the model, so each has its own page and address. HY-UW, the closest sibling, is also published in English: HY-UW weighing module.
- No invented differences: the company documentation contains no statement such as "this one is the improved version" or "this one has an extra structure", so this page writes none and infers none. Saying plainly that the documentation is silent is safer than guessing a difference for the customer.
What are the specifications, and where does each value come from?
Short answer: the table below lists the documented values of HY-UWS-M row by row with the source, and the right-hand column translates each value into what has to be judged at selection and installation. Values are transcribed as given: no conversion, no merging, and no capacity steps or items added beyond the documentation. No drawing was provided for this model, so the table has no "wiring diagram" row and no "dimensions" row (reason at the end of this section).
| Parameter | Value (source) | What it determines |
|---|---|---|
| Model | HY-UWS-M Company documentation | The model reference used for ordering and enquiries. For this model, HY-UW, HY-UW-M and HY-UWS the documentation is identical word for word on main features, wiring and capacity and states no difference (see the section above), so quote the full suffix and check it against the shipping documentation. |
| Category | Weighing module Company documentation | It is a structural part plus a load cell; capacity, material and mounting dimensions all matter together — comparing cell data alone is not enough. |
| Capacity steps | 5, 10, 20, 30, 50, 75, 100, 200, 300, 500 kg Company documentation (10 steps, transcribed) | The maximum load a single module carries. Total system capacity = rated capacity × number of modules, so calculate vessel dead weight and product weight first, then take the next step up. |
| Material and sealing | Stainless-steel hermetically sealed load cell Company documentation | This sets the environments it can be used in: a welded sealed stainless housing is one precondition for damp, washdown areas. For more aggressive media or high temperature the documentation gives no rating, so check the actual conditions. |
| Protection | IP68 Company documentation | The documented rating applies to the sealed module body. On site, check the cable entry and the junction box sealing to the same standard — replacing the module does not solve water getting into the junction box. |
| Structural features | Spherical joint keeping the module vertical under load; support bolts against tipping; simple and quick installation; easy maintenance, saving downtime Company documentation | The spherical joint keeps the module vertical under load and absorbs small angular errors of the mounting face; the support bolts decide whether the vessel can tip. Both are checked after mounting, against verticality and the two mounting faces, as in the installation table below. |
| Wiring system | 6-wire (+excitation / −excitation / +signal / −signal / +sense / −sense) Company documentation | Six wires add a +sense / −sense pair over a 4-wire cell. According to the public technical literature, that pair compensates excitation loss over long cable runs, so it earns its keep when the cable from the module to the indicator or junction box is long. Whether to use it, and how to terminate it, is set by the shipping documentation and the wiring diagram of the unit. |
| Colour code | Green = +excitation; black = −excitation; white = +signal; red = −signal; yellow = +sense; blue = −sense (6 wires) Company documentation | Field wiring reference. The nameplates on the photographs of this model show two different codes: one written by colour (matching this row, plus yellow (long) = shield), and one written by English terminal name (+EXC(Red) / −EXC(Black) / +SIG(Green) / −SIG(White) / Shield), the second matching the company installation instructions. Both are reproduced here and neither is chosen for the customer; before installation work from the shipping documentation and the wiring diagram of the unit, and do not copy colours across batches. (Both codes in full below.) |
| Documented applications | Batching control on small and medium reactors in chemical, pharmaceutical and food plants Company documentation (transcribed) | An industry direction, not a claim that it suits every case in those industries; check vessel dead weight, product weight, number of feet and site conditions machine by machine. |
Values and wording are transcribed from the company documentation. Explanations added on this page carry their own source and come from public technical literature, not from a company commitment. The table has 9 rows.
Why are there two wiring colour codes?
Short answer: the body text and the specification table above reproduce the set from the company product documentation (product page text), 6 wires: green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense. Two other codes for the same model number appear in the company documentation set; both are reproduced here, neither is merged and neither is chosen for the customer:
- Nameplate in photograph 1 of this unit: written by colour, with the same content as the set above, plus one extra line — yellow (long) = shield.
- Nameplates in photographs 2 and 4 of this unit: written by English terminal name — +EXC(Red) excitation positive (red), −EXC(Black) excitation negative (black), +SIG(Green) signal positive (green), −SIG(White) signal negative (white), Shield / braided shield. This set matches the definition the company installation instructions give for HY-UW and HY-UWS (0 to 500 kg): red = excitation +.
In other words: the product page text and the nameplate in photograph 1 use green = +excitation; the nameplates in photographs 2 and 4 and the company installation instructions use red = EXC+. Both appear under this model number and neither cancels the other. Before installation, work from the shipping documentation and the wiring diagram of the unit, do not copy colours across batches, and wire to whichever code the nameplate on the unit in hand shows.
This section states only what the documentation and the photographs contain. It does not judge which set is newer or which one is right; that calls for a check on the physical unit and is not replaced here.
Why are these four rows missing?
Short answer: the company documentation states no accuracy or long-term stability figures for this model and provides no drawing (so the wiring diagram and the dimensions are governed by the shipping documentation). This page infers nothing and gives no estimated value.
The drawing item is explained separately because its reason differs from a value that was simply not written down: the company documentation provides no drawing for this model, so the wiring diagram and the dimensions follow the shipping documentation. There is no wiring diagram, no dimension drawing and no mounting arrangement drawing under this model number, and this page does not borrow drawings from other models in the family (each of them has its own dimension steps, so a borrowed drawing would be a wrong value). Those two rows are therefore left out entirely, rather than filled with a "not given" placeholder.
Which value applies under which working conditions?
Short answer: check the capacity per module against dead load + live load ≤ rated capacity × number of modules × 70%, then take the next step up from the result; the number of modules follows the number of support points. (Method quoted from public technical literature.)
dead load + live load ≤ rated capacity × number of modules × 70%
The formula is repeated in plain text so it can be copied, sent to a workshop group or printed. Worked examples are on the Selection & Resources page.
Case-by-case guide (you can work straight through it)
| Your situation | What to do | Basis |
|---|---|---|
| The vessel already has support feet | Take the number of modules from the number of feet: 3 feet, 3 modules; 4 feet, 4 modules | Public technical literature |
| New vessel, standing vertically, cylindrical | Three-point support is the more stable arrangement; where wind, rocking or vibration come into play, four-point support is preferable | Public technical literature |
| The calculated capacity per module falls between two steps | Take the next step up, never down | Public technical literature |
| How many modules per system, and which structure | Use one fixed module and one semi-floating module per system, with floating modules for the rest; systems are usually supplied as a set of three or a set of four | Public technical literature |
| Damp area, washdown required | This model is a stainless-steel hermetically sealed load cell with IP68; check the cable entry and the junction box with the same sealing approach | Values from company documentation |
| All 6 wires have to be connected (including a sense pair) | Map each of the six positions to the junction box and the indicator terminals; for the colour code see the specification table above and the note in that section, and follow the nameplate on the unit in hand | Wire positions from company documentation; practice from company installation instructions |
| Replacing an old module without changing the foundation | No drawing was provided for this model, so no dimensions are published here: measure the existing hole pattern and the available height first, then check against the shipping documentation and the unit | No drawing supplied for this model |
Where does it fit, and where does it not?
Short answer: what the company documentation and the sourced content of this page support is batching control on small and medium reactors in chemical, pharmaceutical and food plants, plus the damp, washdown areas implied by the hermetically sealed stainless cell and IP68. Items the documentation does not give — accuracy and long-term stability figures, material grade, temperature range, corrosion rating and a drawing for this model — are not inferred here, and no conclusion is drawn for the customer.
Fits (documented)
- Batching control on small and medium reactors: the documented industry direction is chemical, pharmaceutical and food plants. (Company product documentation)
- Damp workshops that need washdown: based on the stainless-steel hermetically sealed load cell and IP68; the precondition is that the cable entry and the junction box are sealed to the same standard. (Values from company documentation)
- Replacing the old modules of existing equipment: a module mounts easily on vessels of any shape and suits retrofits of existing plant. (Quoted from the public technical literature "Sizing and installation of weighing modules")
- Turning a vessel into a weighing system: a vessel, hopper or reactor becomes a weighing system once modules and an indicator are fitted. (Quoted from the public technical literature "Sizing and installation of weighing modules")
- Deciding between static and dynamic modules: a static module suits static weighing with small side forces; a dynamic module suits machinery that takes horizontal forces, such as production lines and conveyors. Where material is fed vertically into a hopper, tank or reactor by conveyor or pump, choose a static module; where material is fed horizontally onto a platform or into a vessel and produces a horizontal impact, choose a dynamic module. (Quoted from the public technical literature "Sizing and installation of weighing modules")
Boundaries and exclusions (read these too)
- The company documentation gives no accuracy or long-term stability figures, no material grade, no temperature range and no corrosion rating: none of these is inferred here, and no estimated value is published; where a figure is needed, check it against the process and the site. (Basis: not recorded in the company documentation)
- There is no drawing for this model from the company documentation: the wiring diagram and the dimensions can only follow the shipping documentation; do not work from the drawings of other models in the family. (Basis: no drawing supplied for this model)
- Do not infer from the model suffix that this model has more or less of anything than its siblings: the documentation is identical word for word on three items and states no difference; check the model against the shipping documentation. (Basis: company product documentation)
- Never mix capacities within one weighing system: check module capacity before mounting. (Quoted from the company installation instructions)
- No welding current may pass through the load cell: during welding no current at all — arc welding and the like — may pass through the module or the cell. (Quoted from the company installation instructions)
- The vessel must not be mechanically tied to other parts that the modules do not carry, or the weighing will be wrong. (Quoted from the public technical literature "Sizing and installation of weighing modules")
- Product piping that is left untreated defeats calibration: run all pipes connected to the vessel horizontally so that they do not hang the vessel, and use flexible connections wherever possible. (Quoted from the public technical literature "Sizing and installation of weighing modules")
What does it look like, and are there drawings for this model?
Short answer: the three photographs below are of this model: the assembled unit, another angle, and a view of the nameplate on the side of the load cell. There is no drawing for this model — the company documentation provides no wiring diagram and no dimension drawing, and this page does not substitute drawings from other models in the family. The images are local files; the page loads no external resources.
All three photographs are company product images, used unaltered, each carrying a light Hengyuan watermark. No drawing was provided for this model and no drawing from another model fills the gap, so this section has no wiring diagram and no dimensions. Where an image and the written documentation disagree, the written documentation governs.
What matters during installation and wiring?
Short answer: whether a module installs well comes down to three things — foundation stiffness and level, the verticality of the module against its mounting face, and whether external load paths such as piping and welding have been dealt with. Every row below gives a figure or an action that can be checked. Wire to the shipping documentation and the wiring diagram of the unit; the colour code follows the shipping documentation.
| Item | Requirement | Source |
|---|---|---|
| Verticality | The vertical axis of every module must coincide with the perpendicular of the mounting plate, with a deviation of no more than 1.5°; any unevenness or out-of-plumb is corrected with shims or the like | Company installation instructions |
| Frame and base plate stiffness | The frame and base plate that carry the module must be rigid enough; the stiffness has to reach 1/1000 | Company installation instructions |
| Top and bottom mounting faces | All modules fully connected on both mounting faces, with no unevenness, and loaded evenly | Company installation instructions |
| Levelling | After mounting three or four modules under the vessel feet or brackets, rock the top plate by hand; if it moves, the module is not level — shim with steel plate until it no longer moves | Company installation instructions |
| Bolt tightening | Tighten every bolt diagonally: pre-tighten first, then torque to specification | Company installation instructions |
| Fixing method | Once the module is level, either bolt it — top plate to the vessel foot or bracket, base plate to the steelwork or the floor — or weld it (note: no welding current may pass through the module) | Company installation instructions |
| Welding | No other current (arc welding and the like) may pass through the load cell, or the cell will be damaged | Company installation instructions |
| Cable | Do not tension the cable, so that no pulling force reaches it and changes the electrical behaviour; protect the cable from cuts and abrasion | Company installation instructions |
| Handling | Never lift the module by its cable when taking it out of the packing; avoid knocks and do not let the module fall from height | Company installation instructions |
| Module capacity | Check module capacity before mounting; never use modules of different capacities in one weighing system | Company installation instructions |
| Wiring and re-check | Connect the module cables to the junction box as the wiring diagram requires; complete the run from the junction box to the display and control indicator; re-check the connections; check that the supply voltage is normal | Company installation instructions |
| Bracket skew | Skew of the upper bracket to the horizontal must not exceed 0.5°; twist or skew of the base bracket structure to the horizontal must not exceed 0.5° | Public technical literature |
| Foundation | The foundation (or floor) carrying the vessel must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is one of the better choices | Public technical literature |
| Piping | Run all pipes connected to the vessel horizontally so that they do not hang the vessel; place the first pipe support as far from the vessel as possible; use flexible connections wherever possible | Public technical literature |
| Independent load path | The vessel must act on the load cells alone and must have no mechanical tie to other parts that the cells do not carry | Public technical literature |
| Earthing | Each module should have its own independent earth | Public technical literature |
| Service access | Mount the modules where they can be serviced | Public technical literature |
| Calibration conditions | At the design stage allow for the positions where test weights will sit and for the jacking points needed during installation and service; calibration must be carried out after installation | Public technical literature |
The table collects the general requirements of the company installation instructions and of public technical literature, and applies to this class of module; site practice and final acceptance remain with the shipping documentation and the actual conditions. No wiring diagram was provided for this model, so wiring follows the shipping documentation and the unit. Calibration steps at the indicator are covered in the FAQ.
Where do the facts come from?
- Company product documentation (HY-UWS-M product page text): model, category, capacity steps, stainless-steel hermetically sealed load cell and IP68, structural features, 6-wire wiring and colour code, documented applications; and the material for the three-item side-by-side check against HY-UW, HY-UW-M and HY-UWS.
- Company installation instructions: the make-up of a module and of a weighing system, module count and foundation requirements, installation tolerances and stiffness requirements, fixing and welding prohibitions, cable and wiring requirements; and the second wiring definition (red = excitation +, for HY-UW and HY-UWS at 0 to 500 kg).
- The three photographs of this model: the assembled form and the wiring code on the nameplate; the nameplate in photograph 1 is written by colour, those in photographs 2 and 4 by English terminal name.
- Public technical literature ("Sizing and installation of weighing modules" and similar, marked passage by passage): module construction, classification and selection principles, module count and support arrangement, piping and calibration requirements, static and dynamic criteria.
Values in the tables are transcribed from company documentation and are not a commitment for a specific project; the final specification is confirmed against the application. No drawing was provided for this model, so the wiring diagram and the dimensions follow the shipping documentation.
Still unsure which capacity step fits?
Tell us these in one go and we can suggest capacity and module count directly: vessel dead weight, product weight, number and layout of support feet, product name and characteristics, site conditions, and whether it is a new build or a retrofit. Quote the full model suffix when you write.