What is a fixed weighing module, and where does it mount?
Short answer: a weighing module is a practical structural accessory for load cells, built from a top plate, a base plate, the load cell, a load-bearing column and support bolts. Depending on the load-bearing column and the top plate, modules fall into three structures: fixed, semi-floating and full-floating; this page covers the fixed one. (Public technical literature, "Selection and installation of weighing modules".)
A module mounts easily on vessels of almost any shape and suits retrofits: whether a vessel, a hopper or a reactor, adding modules and a weight indicator turns it into a weighing system. (Public technical literature, same source.)
Mounting position is usually the lower part of the scale body — feet, pallet and similar — or the upper part, at the waist of a vessel, tank or hopper. All modules of one weighing system must sit in the same horizontal plane. (Public technical literature, same source.)
How it differs from buying a load cell on its own
A module makes the load cell, the load-bearing structure and the mounting connection one assembly: bolt it under a foot and it takes load, so part of the weighing error caused by poor installation is absorbed by the structure itself. A bare load cell leaves the load point, the restraint and the mounting face for the fitter to solve. (Public technical literature, same source.)
Where it sits in a weighing system
A weighing control system is normally made of a weight indicator, a junction box, the weighing modules and cable: the modules take the load, the junction box sums the signals of several modules, the indicator displays and controls. (Company installation instructions.)
A system usually uses 3 to 6 sets of modules, up to 12. The foundation carrying the modules must meet the stiffness requirement and lie in one plane, or be adjustable to one plane, so that every module carries an even share. (Company installation instructions.)
How do fixed, semi-floating and full-floating differ, and how many of each go into one system?
Short answer: the three are separated by the load-bearing column and the top plate, not by capacity: in one weighing system, use one fixed module and one semi-floating module, with the rest made up by full-floating modules; a set is usually three modules or four, three for three-point support and four for four-point support. So the fixed type is usually used once per system. (Public technical literature, "Selection and installation of weighing modules".)
That is also how this page differs from the model pages: HY-CWC-M and HY-UW describe a specific model, where capacity, material, wiring and dimensions follow the model. This page describes a structural type: how the fixed one is built, where it mounts and how it is wired. In one system, confirm the exact model and capacity for all three structures together, and take the number of modules from the number of support points.
| Item | Content | Source |
|---|---|---|
| How many structures | Depending on the load-bearing column and the top plate: fixed, semi-floating and full-floating | Public technical literature, "Selection and installation of weighing modules" |
| How one system is made up | One fixed module and one semi-floating module, the rest made up by full-floating modules | Public technical literature, "Selection and installation of weighing modules" |
| Usual set sizes | Usually a set of three or a set of four; three for three-point support, four for four-point support | Public technical literature, "Selection and installation of weighing modules" |
| The fixed one | The subject of this page; usually used once per system, together with semi-floating and full-floating modules | Public technical literature, "Selection and installation of weighing modules" |
| Confirming an order | This page describes a structural type, not an ordering code; confirm the exact model and capacity when ordering | Company product documentation |
The table lists how the three structures are divided and how many of each are used; the part-to-model mapping is checked on the model pages. Sizing method and worked examples are on Selection & Resources.
What are the specifications, and where does each value come from?
Short answer: the table lists this structure's product values with their source, and the right-hand column turns each value into the decision it drives at sizing and installation time. Figures are transcribed as printed: not converted, not merged, and nothing added that the documentation does not contain. The company documentation does not state a capacity, a protection rating, an accuracy figure or a long-term stability figure for this structure, so those four have no row here and no value is inferred.
| Parameter | Value (source) | What it determines |
|---|---|---|
| Model / product name | Fixed weighing module Company product documentation | A product name defined by the load-bearing column and the top plate (three structures: fixed / semi-floating / full-floating), not an ordering code; confirm the exact model and capacity when ordering. (Public technical literature plus company product documentation.) |
| Category | Weighing module Company product documentation | A structural part plus a load cell: at sizing time look at capacity, material and mounting dimensions together, not at the load cell figures alone. |
| Material and surface finish | Alloy steel structure; nickel-plated surface Company product documentation | Alloy steel is the strength base of the load-bearing parts; nickel plating is the anti-corrosion route. Plating is a surface treatment, while stainless steel hermetic welding is a different anti-corrosion route, so do not apply another model's material wording to this structure. |
| Structural features | Can be mounted directly on the floor or on a foundation structure; support bolts prevent the equipment from tipping Company product documentation | Mounting straight onto floor or foundation keeps the foundation requirement simple; the support bolts give it a built-in anti-tip measure, which is the item to check on site when the vessel takes horizontal impact. |
| Wiring system | 4-wire with shield (+excitation, −excitation, +signal, −signal, plus one shield wire) Company product documentation and specification drawing | 4-wire with shield is the simplest connection: two excitation wires, two signal wires and a shield. The shield suppresses interference from variable-frequency drives and power cable; the field practice is to earth the shield at one end and keep signal cable away from power cable. (Practice from public technical literature.) |
| Colour code | Red = +excitation; black = −excitation; green = +signal; white = −signal (4 wires). The wiring diagram on the company specification drawing also marks light yellow = shield Company product documentation (4 wires transcribed as printed) and specification drawing | The field reference for terminating. Colour order differs between models in the public installation material, so before work starts follow the documentation shipped with the unit and the wiring diagram on the unit itself, and do not copy colours from another model. |
| Wiring diagram | Red = excitation+; green = signal+; black = excitation−; white = signal−; light yellow = shield Company specification drawing (drawing 3 below) | One shield wire more than the colour code row: the shield suppresses drive and power-cable interference, and the field practice is to earth it at one end and keep signal cable away from power cable. (Practice from public technical literature.) |
| Dimensions | Lateral drawing: 150, 124, 4-Ø11, 102, 3, 32, 226, 286, 4-Ø13; end view: 128, 102, 28, 80, 112, 23 (the drawings mark no unit; transcribed as printed) Company specification drawings (drawings 4 and 5 below) | How tall the module stands, where the mounting holes go and what the hole spacing is. Before changing a module or a foundation, measure the existing hole positions and available height, then check them against these two sets; the drawings mark no unit and state no corresponding capacity or model step, and none is inferred here. |
| Documented applications | Suited to platform scales, mixing plants and batching scales Company product documentation | This row states a direction of use, not a claim that any such site will fit: for a specific machine, still check vessel dead weight, product weight, number of feet and site conditions. |
All values and wording are transcribed from company documentation as printed, including the fact that a value is not given. Every explanation added on this page carries its own source and is public technical literature, not a company commitment. The company documentation does not state a capacity, a protection rating, an accuracy figure or a long-term stability figure for this structure: those four rows are not set, and no value is inferred.
Which value applies in which working condition?
Short answer: check the single-module capacity first against "dead load + live load ≤ rated capacity × number of modules × 70%", then set the number of modules from the number of support points, then complete the set across the three structures: one fixed, one semi-floating, the rest full-floating. The company documentation does not state a capacity for this structure, so confirm the exact model and capacity against the working condition. (Sizing approach from public technical literature.)
dead load + live load ≤ rated capacity × number of modules × 70%
The formula is written out in words so it can be copied, sent to a work group or printed for a design office; the wording is quoted from public technical literature. Worked examples are on Selection & Resources.
Static or dynamic load first: how the material enters the vessel
Static-load modules suit mainly static weighing where lateral forces are small; dynamic-load modules suit machinery that takes horizontal forces, such as production lines and conveyors. (Public technical literature, "Selection and installation of weighing modules".)
When material is fed vertically into a hopper, tank, reactor or silo by conveyor or pump, use static-load modules. When material is fed horizontally onto the scale or into the vessel, a horizontal impact force appears, and dynamic-load modules should be used. (Public technical literature, same source.)
Case by case (can be followed directly)
| Your case | What to take | Basis |
|---|---|---|
| The vessel already has support feet | Set the count from the number of feet: 3 feet, 3 modules; 4 feet, 4 modules. Of these, 1 fixed and 1 semi-floating, the rest made up by full-floating modules | Module count from public technical literature; the three-structure arrangement from public technical literature, "Selection and installation of weighing modules" |
| New vessel, vertical cylinder | Three-point support is the more stable choice; where wind, sway or vibration matter, four-point support is preferred | Public technical literature |
| Calculated single-module capacity falls between two steps | Take the next step up, not down | Public technical literature |
| Material is fed horizontally into the vessel | A horizontal impact force appears; use dynamic-load modules | Public technical literature, "Selection and installation of weighing modules" |
| Long cable run from module to indicator | This structure is 4-wire with shield and has no sense wires; earth the shield at one end, keep signal cable away from power cable, and check against the indicator terminals | Wiring system from company product documentation; shield practice from public technical literature |
| Replacing an old module without changing the foundation | Measure the existing hole positions and available height first, then check them against the two dimension sets on this page | Dimensions from company specification drawings |
Where does it fit, and where does it not?
Short answer: what company product documentation and the sourced content on this page support is the "platform scales, mixing plants and batching scales" group of sites, plus the mounting method that comes with "can be mounted directly on the floor or a foundation structure, with support bolts against tipping". What the company documentation does not give — capacity, protection rating, accuracy and long-term stability, material grade, service temperature — is not inferred here and is not decided on the customer's behalf.
Fits (with a source)
- Platform scales, mixing plants and batching scales: the documented applications row states that the structure suits these. (Company product documentation.)
- On the floor or on a foundation structure: this structure can be mounted directly on the floor or on a foundation structure, with support bolts to prevent the equipment from tipping. (Company product documentation.)
- Retrofitting existing equipment: modules mount easily on vessels of almost any shape and suit retrofits, whether a vessel, a hopper or a reactor. (Public technical literature, "Selection and installation of weighing modules".)
- Where structural duties must be split inside one system: one fixed and one semi-floating module per system, the rest full-floating, for three-point or four-point support. (Public technical literature, same source.)
Limits and cases that do not apply
- Capacity, protection rating, accuracy and long-term stability are not stated for this structure: none of the four can be inferred here, no value is published and no row is set; where any of them matters, check the specific model and the working condition. (Basis: the company product documentation does not record them.)
- This page is not an ordering page: fixed / semi-floating / full-floating are product names divided by structure, so quote the exact model and capacity rather than the word "fixed" alone. (Basis: public technical literature, "Selection and installation of weighing modules".)
- Never mix modules of different capacity in one weighing system. (Company installation instructions.)
- Welding current must not pass through the load cell: no current through the module during welding, or the cell is damaged. (Company installation instructions.)
- The vessel must not be tied mechanically to any part that the modules do not carry, or the reading will be wrong. (Public technical literature, "Selection and installation of weighing modules".)
- Product piping left unhandled spoils the reading: run every pipe connected to the vessel horizontally so it does not hang the vessel, use flexible connections where possible, and keep the first pipe support point as far from the vessel as possible. (Public technical literature, same source.)
What do the unit and the specification drawings look like?
Short answer: one photograph of the unit and five company specification drawings: mounting arrangement, module layout (three structures shown inside), wiring diagram, dimension drawing in side view, and dimension drawing in end view. All images are local files; the page loads no external resource.
One product photograph and five specification drawings, used unaltered. Neither dimension drawing marks a unit, and none is added here. Where an image and the written documentation disagree, the written documentation governs.
What matters during installation and wiring?
Short answer: whether a module performs comes down to three things: base stiffness and level, connection verticality, and whether force bypasses such as piping and welding have been dealt with. Each row below gives a figure or an action that can be checked, from public installation literature and the company installation instructions.
| Item | Requirement | Source |
|---|---|---|
| Verticality | The vertical axis of every module coincides with the perpendicular to the mounting plate, deviation not more than 1.5°; correct with shims where it is out | Company installation instructions |
| Frame and base plate stiffness | Frame and base plate carrying the modules must be rigid enough; stiffness of 1/1000 is required | Company installation instructions |
| Bracket skew | Skew or twist of the upper bracket and the base bracket relative to horizontal must not exceed 0.5° | Public technical literature, "Selection and installation of weighing modules" |
| Foundation | The foundation or floor carrying the vessel must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is the better choice | Public technical literature, "Selection and installation of weighing modules" |
| Fixing method | Once the module is shimmed level, fix it either with bolts or by welding; no welding current may pass through the weighing module | Company installation instructions |
| Levelling | With the module under a vessel foot or bracket, rock the top plate by hand; if it moves, the module is not level, so shim it until it does not move | Company installation instructions |
| Bolting | Tighten every bolt diagonally, pre-tighten first, then torque to specification | Company installation instructions |
| Load and axis | Upper and lower mounting faces of every module fully connected, with no unevenness, and load shared evenly; where unevenness or skew appears, correct it with shims or equivalent | Company installation instructions |
| Cable | Do not stretch the cable, or tension will affect electrical performance; protect the cable and keep the sheath free of cuts | Company installation instructions |
| Handling | Never lift the module by its cable when taking it out of the packing; avoid knocks and prevent drops from height | Company installation instructions |
| Piping | Run every pipe connected to the vessel horizontally so the pipe does not hang the vessel; set the first pipe support point as far from the vessel as possible and use flexible connections where possible | Public technical literature, "Selection and installation of weighing modules" |
| Calibration conditions | Allow for test-weight positions and for jacking points used during installation and service at the design stage; give every module its own earth, and calibrate after installation | Public technical literature, "Selection and installation of weighing modules" |
| Wiring and re-check | Wire the load cell cable to the junction box as the diagram requires, run the cable from junction box to indicator, re-check every connection and verify the supply voltage | Company installation instructions |
The table collects general requirements from public installation literature and the company installation instructions, and applies to installing this class of module; field practice and the final judgement still follow the documentation shipped with the unit and the actual working condition. Indicator-side calibration steps are on the FAQ page.
Where do the facts come from?
- Company product documentation (fixed weighing module product data): product name, category, material and surface finish, structural features, 4-wire connection and colour code, documented applications.
- Company product specification drawings: mounting arrangement, module layout with the three structures, 4-wire with shield wiring diagram, dimension drawings in side view and end view.
- Company installation instructions: installation deviation and stiffness requirements, the two fixing methods, the prohibitions on mixing capacities and on welding current, levelling and handling, wiring and re-check.
- Public technical literature ("Selection and installation of weighing modules" and similar, marked at each sentence it supports): module construction, the three structures and module counts, static versus dynamic criteria, foundation and piping requirements, calibration conditions.
Values in the tables are transcribed from company documentation and are not a commitment for a specific project; capacity, protection rating, accuracy and long-term stability are not stated for this structure and none is inferred. Final specifications are confirmed against the working condition. First published 2026-10-12 on the Chinese page; this English page first published 2026-10-24.
Still unsure where this one goes, or how many a set needs?
Tell us these in one go and we can answer on structure and count directly: vessel dead weight, product weight, number and layout of support feet, how the material enters the vessel, site conditions, and whether it is a new build or a retrofit.
- All weighing modules, by structure and model →
- Sizing formula, worked examples, the four duties and the eight installation faults →
- HY-CWC-M weighing module, a specific model page, 6-wire with shield →
- HY-UW weighing module, stainless steel IP68, 6-wire, for small and medium reactors →
- The reading is wrong or keeps jumping: what to check first →