What is it and where does it mount?
Short answer: a weighing module is a structural accessory built around a load cell — top plate, base plate, load cell, load-bearing column and support bolts. It mounts under vessel feet or on the vessel body, and turns weight into a signal for the indicator.
On this model the body is a stainless plate structure carrying a shear-beam load cell, with an adjustable horizontal restraint bolt and a self-aligning load head that keeps the load application point correct. The load cell housing is hermetically welded, hence IP68.
Static vs dynamic: static-load modules suit applications with small lateral forces. Where product enters the vessel horizontally (conveyors, screw feed into the side), horizontal impact occurs and a dynamic-load module is the appropriate choice. The documentation states this distinction explicitly; it is one of the few places where the family members differ.
How does it differ from the other 0.5–20 t models?
| Model | Material | Wiring | Protection | Load type |
|---|---|---|---|---|
| HY-CWC-M | Stainless steel, hermetically sealed | 6-wire | IP68 | Static |
| HY-CWC | Stainless steel | 4-wire with shield | Not stated for this model | Dynamic |
| HY-CW | Stainless steel | 4-wire | Not stated for this model | Per documentation |
| HY-CW-M | Alloy steel, nickel-plated | 6-wire with shield | Per documentation | Per documentation |
Values are transcribed from company documentation. Where a cell reads "not stated", the documentation gives no value for that model and none is inferred.
What are the specifications?
| Parameter | Value (source) | What it determines |
|---|---|---|
| Model | HY-CWC-M Company documentation | Order reference; quote the full suffix. |
| Capacity steps | 0.5, 1, 2, 3, 5, 10, 15, 20 t Company documentation | Maximum load per module; system capacity is rated capacity × number of modules. |
| Material and sealing | Stainless steel, hermetically welded sealed load cell Company documentation | Suitable for damp and washdown areas; other media need separate checks. |
| Protection | IP68 Company documentation | Sealed module body; cable entries and junction box must match. |
| Wiring | 6-wire: excitation +/−, signal +/−, sense +/− Company documentation | Sense wires compensate excitation loss on long runs. |
| Colour code | Green +excitation, black −excitation, white +signal, red −signal, yellow +sense, blue −sense Company documentation | Field reference. The installation instructions give a second set for the 0.5–3 t and 8–20 t ranges; wire to the nameplate of the unit in hand. |
| Structural features | Self-aligning load head; adjustable horizontal restraint bolt; alignment tool; alloy construction with a stainless sealed cell Company documentation | The load head keeps the application point correct for repeatability; the restraint limits lateral movement. |
| Documented applications | Batching control on tanks and vessels in chemical, pharmaceutical and food plants Company documentation | An industry direction, not a blanket claim. |
What are the dimensions?
Short answer: the company drawing set contains a per-step dimension table (four capacity groups, 16 dimensions per group) plus two dimensioned views. Dimensions are taken from the drawings; where the drawing omits units, no unit is added here.
| Group | Covers | Source |
|---|---|---|
| Group 1 | 0.5 t, 1 t, 2 t | Company drawing |
| Group 2 | 3 t, 5 t | Company drawing |
| Group 3 | 10 t, 15 t | Company drawing |
| Group 4 | 20 t | Company drawing |
The drawings are published on the Chinese product page in full. Dimension values must be read per capacity group; the mounting hole pattern changes with the group, so confirm the group before pouring a foundation.
How is it wired?
| Source | Excitation | Signal | Sense |
|---|---|---|---|
| Product page | Green = +, black = − | White = +, red = − | Yellow = +, blue = − |
| Installation instructions (0.5–3 t) | Red = +, black = − | Green = +, white = − | Silver = shield |
The mapping differs between the two sets; the same green wire means +excitation in one and +signal in the other. Wire to the nameplate of the unit in hand and to the shipping documentation.
Where does it fit, and where does it not?
- Fits: tanks, silos, reactors and platforms with small lateral forces; damp or washdown areas with sealed cable entries and junction box.
- Does not fit: applications with significant horizontal impact from side entry — use a dynamic-load model instead.
- Not for: anything requiring an accuracy figure or a statutory metrology statement — the documentation provides neither, and none is implied here.
- Never mix capacities in one weighing system.
What does it look like?
Where an image and the written documentation disagree, the written documentation governs.
Where do the facts come from?
- Company product documentation: model, capacity steps, material and sealing, IP68, 6-wire wiring, structural features, documented applications.
- Company drawings: per-step dimension table, wiring diagram, mounting arrangement.
- Company installation instructions: assembly requirements, tolerances, welding prohibition, second wiring definition.
- Public technical literature: sizing formula and the 70% margin, module count rules, static vs dynamic criteria.
Values are transcribed from company documentation.
Still unsure which step fits?
Tell us vessel dead weight, product weight, number of support feet, product characteristics and site conditions.