HY-MTB Load Cell: 5 kg to 500 kg, 4-Wire, Stainless Steel, IP68

HY-MTB is a stainless-steel column-type load cell with a low mounting height, for packing scales, belt scales and batching control in chemical, medical and food plants. Against its sibling HY-MTB-M the only difference is the wiring: this one is 4-wire, the M is 6-wire with a sense pair; every other parameter is the same.

Not sure between 4-wire and 6-wire:

+86 183 5123 8137

Short answer: HY-MTB covers 5, 10, 20, 30, 50, 75, 100, 200, 300 and 500 kg in 10 steps; stainless steel, hermetically welded, IP68; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal), with no sense pair; sensitivity 2±0.002 mV/V, input resistance 387±4 Ω, output 350±1 Ω, safe overload 150%, ultimate 300%, cable 3 m.

How does it differ from HY-MTB-M?

Short answer: only the wiring. The other three items — main features, capacities, technical parameters — are written as the same set in the company documentation.

HY-MTB vs HY-MTB-M (company documentation)
Item HY-MTB (this page) HY-MTB-M
Wiring 4-wire: red +excitation, black −excitation, green +signal, white −signal 6-wire: adds yellow +sense, blue −sense
Main features Identical text Identical text
Capacities 10 steps (5 kg to 500 kg) 10 steps, identical
Technical parameters 19 items, identical 19 items, identical

The company documentation states no difference beyond wiring for these three items. This page transcribes that as-is and does not decide for the customer which version is "better".

How is 4-wire wired, and what does it change?

Short answer: 4-wire has only the excitation pair and the signal pair — no sense pair. The sense pair compensates the excitation drop along a long cable; without it, a longer or thinner cable leaves less voltage at the bridge, and the error grows.

4-wire colour code (company documentation)
Colour Terminal Function
Red+input+ excitation
Black−input− excitation
Green+output+ signal
White−output− signal
4-wire vs 6-wire: how to choose on site
Situation What to do
Short cable (near the supplied 3 m) 4-wire is enough; the drop is small
Cable must be extended Check the drop first: longer and thinner cable means less voltage at the bridge. Where it matters, use the 6-wire version and let the indicator compensate
Indicator already 6-wire A 4-wire cell can be connected to a 6-wire indicator (link the sense terminals at the indicator as documented), but the compensation is then lost

⚠️ One documentation difference, transcribed without merging: the product page text lists only the four wires and does not mention a shield, while the wiring diagram on the same page marks an additional pale-yellow = Shield. Both are transcribed here; the shipping documentation and the unit itself govern on site. Earth the shield at one end only; both ends create a ground loop.

What are the specifications?

Short answer: the company documentation gives 19 parameters, identical to HY-MTB-M, transcribed below.

HY-MTB specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-40 to +65
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ387±4
Output resistanceΩ350±1
Insulation resistanceMΩ5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP68
Cable lengthm3

What are the dimensions?

Short answer: the documentation provides two drawings — an end view and a top view — which together describe the outline. Units are not marked, and the top view carries a dimension A with no value given (it varies with the capacity step). Nothing is added here.

Dimensions transcribed from the drawings
Drawing View Values shown
Drawing 2 End view Height 20; nose 45; end diameter Φ36
Drawing 3 Top view Overall 123; body width 26; A (no value); spacings 82, 18, 10; holes Φ4, 2-Φ, Φ

Two points stated plainly: ① the drawings do not say which capacity step they belong to (the same outline serves 5 kg to 500 kg), and this page does not assign them; ② A is a variable with no value on the drawing, and none is filled in. A three-row dimension table on the company product page (5/10 kg, 200–300 kg, 500 kg) has its diameter symbol corrupted during capture ("?45", "?8.2"), so it is not used here.

What does it look like?

Short answer: the documentation contains three photographs and three drawings. This page shows the three drawings only: the nameplates on the photographs are not legible at usable magnification (one entirely out of focus, two short of detail), so they are not published here.

HY-MTB wiring diagram: red excitation+, black excitation-, green signal+, white signal-, plus pale-yellow shield
Wiring diagram (4-wire). Company drawing.
HY-MTB end view: height 20, nose 45, end diameter Φ36
End view: 20, 45, Φ36. Company drawing.
HY-MTB top view: 123, 26, A (no value), spacings 82/18/10, holes Φ4 and 2-Φ
Top view: 123, 26, A, 82, 18, 10, Φ4, 2-Φ. Company drawing.

No usable product photograph is published for this model. Where an image and the written documentation disagree, the written documentation governs.

Where does it fit, and where does it not?

Short answer: the documented applications are packing scales, belt scales and batching control in chemical, medical and food plants, with a high-temperature version up to 150 °C. Anything beyond that is not inferred here.

How can I tell whether the cell has failed?

Short answer: three measurements — input across red/black should read 387±4 Ω, output across green/white should read 350±1 Ω, and insulation to the body should stay in the MΩ range.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure between red and black Around 387±4 Ω; an open circuit means a broken internal wire
2 Measure between green and white Around 350±1 Ω
3 Measure insulation from conductors to body MΩ range; a clear drop means moisture or a damaged seal

If the values are normal but the reading is unstable, work through installation, piping, junction box and supply first — see the Selection & Resources page.

Where do the facts come from?

Values are transcribed from company documentation. The documentation contains one protection-type wording carried over from earlier material; this page does not reproduce that rating and makes no claim based on it.