How does it differ from HY-MTB-M?
Short answer: only the wiring. The other three items — main features, capacities, technical parameters — are written as the same set in the company documentation.
| Item | HY-MTB (this page) | HY-MTB-M |
|---|---|---|
| Wiring | 4-wire: red +excitation, black −excitation, green +signal, white −signal | 6-wire: adds yellow +sense, blue −sense |
| Main features | Identical text | Identical text |
| Capacities | 10 steps (5 kg to 500 kg) | 10 steps, identical |
| Technical parameters | 19 items, identical | 19 items, identical |
The company documentation states no difference beyond wiring for these three items. This page transcribes that as-is and does not decide for the customer which version is "better".
How is 4-wire wired, and what does it change?
Short answer: 4-wire has only the excitation pair and the signal pair — no sense pair. The sense pair compensates the excitation drop along a long cable; without it, a longer or thinner cable leaves less voltage at the bridge, and the error grows.
| Colour | Terminal | Function |
|---|---|---|
| Red | +input | + excitation |
| Black | −input | − excitation |
| Green | +output | + signal |
| White | −output | − signal |
| Situation | What to do |
|---|---|
| Short cable (near the supplied 3 m) | 4-wire is enough; the drop is small |
| Cable must be extended | Check the drop first: longer and thinner cable means less voltage at the bridge. Where it matters, use the 6-wire version and let the indicator compensate |
| Indicator already 6-wire | A 4-wire cell can be connected to a 6-wire indicator (link the sense terminals at the indicator as documented), but the compensation is then lost |
⚠️ One documentation difference, transcribed without merging: the product page text lists only the four wires and does not mention a shield, while the wiring diagram on the same page marks an additional pale-yellow = Shield. Both are transcribed here; the shipping documentation and the unit itself govern on site. Earth the shield at one end only; both ends create a ground loop.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-MTB-M, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -40 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 387±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | 5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP68 |
| Cable length | m | 3 |
What are the dimensions?
Short answer: the documentation provides two drawings — an end view and a top view — which together describe the outline. Units are not marked, and the top view carries a dimension A with no value given (it varies with the capacity step). Nothing is added here.
| Drawing | View | Values shown |
|---|---|---|
| Drawing 2 | End view | Height 20; nose 45; end diameter Φ36 |
| Drawing 3 | Top view | Overall 123; body width 26; A (no value); spacings 82, 18, 10; holes Φ4, 2-Φ, Φ |
Two points stated plainly: ① the drawings do not say which capacity step they belong to (the same outline serves 5 kg to 500 kg), and this page does not assign them; ② A is a variable with no value on the drawing, and none is filled in. A three-row dimension table on the company product page (5/10 kg, 200–300 kg, 500 kg) has its diameter symbol corrupted during capture ("?45", "?8.2"), so it is not used here.
What does it look like?
Short answer: the documentation contains three photographs and three drawings. This page shows the three drawings only: the nameplates on the photographs are not legible at usable magnification (one entirely out of focus, two short of detail), so they are not published here.
No usable product photograph is published for this model. Where an image and the written documentation disagree, the written documentation governs.
Where does it fit, and where does it not?
Short answer: the documented applications are packing scales, belt scales and batching control in chemical, medical and food plants, with a high-temperature version up to 150 °C. Anything beyond that is not inferred here.
- Fits: small loads, high cycle counts, dusty or washdown sites, and tight spaces thanks to the low mounting height.
- Where 4-wire suits: short cable runs and systems that do not need compensation at the indicator.
- Where 6-wire suits: longer or thinner cable runs where excitation drop matters.
- Not covered: aggressive media, operation outside -40 to +65 °C, or continuous running above the safe overload.
How can I tell whether the cell has failed?
Short answer: three measurements — input across red/black should read 387±4 Ω, output across green/white should read 350±1 Ω, and insulation to the body should stay in the MΩ range.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure between red and black | Around 387±4 Ω; an open circuit means a broken internal wire |
| 2 | Measure between green and white | Around 350±1 Ω |
| 3 | Measure insulation from conductors to body | MΩ range; a clear drop means moisture or a damaged seal |
If the values are normal but the reading is unstable, work through installation, piping, junction box and supply first — see the Selection & Resources page.
Where do the facts come from?
- Company product documentation: main features, 4-wire colour code, 10 capacity steps, 19 technical parameters.
- Company drawings: wiring diagram (4-wire plus shield), end view, top view.
- Item-by-item check against HY-MTB-M: the two product pages compared directly (features, capacities and parameters identical; wiring differs).
- Public technical literature: load cell selection and installation requirements, the role of sense wires on long runs.
Values are transcribed from company documentation. The documentation contains one protection-type wording carried over from earlier material; this page does not reproduce that rating and makes no claim based on it.
Still unsure which step fits?
Tell us: equipment type (packing / belt / batching scale), load per cell, mounting and space, material and site conditions, how far the indicator is, and whether a high-temperature or explosion-proof version is needed.