HY-0743-M Load Cell: 9 t / 13.6 t / 20 t, 6-Wire, IP68, 9 m Cable

HY-0743-M is a high-capacity load cell, 9 t, 13.6 t and 20 t, for ground-level platforms and batching in chemical, food and pharmaceutical plants. Compact body, good mounting compatibility, 6-wire with a sense pair, IP68, 9 m cable. Its sensitivity is 1.94, not the 2.0 of most siblings — that matters when you fit or calibrate an indicator.

Not sure about the step:

+86 183 5123 8137

Short answer: HY-0743-M covers 9, 13.6 and 20 t; compact body, good mounting compatibility, IP68; wiring is 6-wire (green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense); sensitivity 1.94±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, operating range -20 to +60 °C, safe overload 150%, ultimate 300%, cable 9 m.

What is it, and does the M mean "module"?

Short answer: the photograph shows the bare load cell, not an assembly with mounting plates and a top plate. In this factory's naming, M usually denotes a module, but this model's photographs show the cell alone (alloy-steel bar body with a cable exit), with none of the module's top and bottom hardware.

⚠️ This matters because "module or bare cell" decides the whole mounting arrangement. The company text never uses the word module either — it says only "compact structure, good mounting compatibility". If you need the module form supplied, say so before ordering (extra mounting parts may be a separate item).

⚠️ Sensitivity 1.94, not 2.0

Most load cells on this site are 2.0 or 2±0.2 mV/V; this one is 1.94±0.002. Two practical consequences:

So this belongs on the checklist for indicator matching, replacement and paralleling. This page does not rule on "can it be swapped directly"; it states the difference plainly.

How is it wired?

Short answer: 6-wire. The text and the drawing agree wire for wire.

6-wire colour code (text and drawing agree)
Colour Function Terminal name
Green+ excitationExcitation(+)
Black− excitationExcitation(−)
White+ signalSignal(+)
Red− signalSignal(−)
Yellow+ senseSense(+)
Blue− senseSense(−)
pale-yellowshieldShield

⚠️ Here it is green = excitation+, white = signal+, red = signal−. That is not the same as the 4-wire HY-1241 on this site (red = excitation+, green = signal+), so never carry a colour order across models. Earth the shield at one end only; at 9 m this is a long run and the shield earthing matters.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below.

HY-0743-M specifications (company documentation)
Parameter Unit Value
SensitivitymV/V1.94±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP68
Cable lengthm9

IP68 covers continuous immersion, which is steadier than IP67 where a batching area is washed down and the floor stands wet.

What are the dimensions?

Short answer: no values are copied here. The drawing carries a capacity-grouped dimension table (titled "0743 9-13.6t"), but the type is only a few pixels high — enlarged, the strokes merge and the digits cannot be told apart. And only the 9–13.6 t sheet exists; the 20 t drawing is missing. Both facts are recorded here.

What the documentation actually contains
Item Situation
Dimension sheets1 (image 03, titled "0743 9-13.6t")
Capacity table present?yes (about 16 columns, two data rows)
Values legible?no (still merged at 8× enlargement)
20 t drawing available?no (title stops at 13.6 t)

⚠️ Why not copy: a dimension drawing exists to be drilled from, and one misread number becomes a scrapped base plate — far worse than "no dimension yet". The field is left empty. Ask us for the drawing of this model and say which step (9 t / 13.6 t / 20 t) — the 20 t drawing has to be supplied separately.

What does it look like?

Short answer: four images are supplied — one product photograph, one dimension drawing (9–13.6 t) and one wiring diagram. Three are used here.

HY-0743-M load cell: natural alloy-steel bar body, mounting holes at both ends, laser marking on the side showing 0743 and the capacity, cable leaving one end; factory watermark
The side carries a laser marking — use it to confirm model and capacity. Company documentation.
HY-0743-M dimension drawing (title 0743 9-13.6t): side and top callouts, plus a capacity-grouped table of about 16 columns whose values are too small to read
Dimension drawing, 9–13.6 t (table values not copied). Company documentation.
HY-0743-M wiring diagram: Green excitation+, Yellow sense+, White signal+, Black excitation-, Blue sense-, Red signal-, pale-yellow shield
Wiring diagram (6-wire plus shield). Company documentation.

⚠️ There is no 20 t dimension drawing — the supplied sheet stops at 13.6 t. Ask separately if you need it.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms and batching in chemical, food and pharmaceutical plants, 9 to 20 t.

The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure green / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure white / red Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

Resistances and sensitivity are different things: normal resistances do not prove the sensitivity is right. Check sensitivity against the laser marking or the shipping documentation.

Where do the facts come from?

Dimensions are omitted because the table values are illegible and no 20 t sheet exists.

Still unsure which step fits?

Tell us: load per cell and cell count, platform or vessel mounting, whether you need the module form with mounting hardware, indicator model (6-wire?), washdown conditions, and which capacity step you need.