First published · Chinese version: HY-QS 称重传感器

You are here: Home > Products > HY-QS

HY-QS Load Cell: Double Shear Beam, High Capacity, 15 t to 50 t, 4-Wire, IP68 by Capacity

HY-QS is a high-capacity load cell, 15 t to 50 t in 5 steps, for the large platforms of truck and rail weighing. Alloy steel, nickel-plated, laser-welded, 4-wire, with a 13 m or 16 m cable. Its protection rating, overload capacity and cable length are all split by capacity, and its operating range is the widest of the models here.

Not sure about the step or the number of cells:

+86 183 5123 8137

Short answer: HY-QS covers 15, 20, 30, 40 and 50 t; alloy steel nickel-plated, laser-welded, 4-wire; sensitivity 2±0.002 mV/V, input 750±10 Ω, output 703±2 Ω, operating range -30 to +70 °C, recommended excitation 10-12 V (max 15 V), cable 13 / 16 m; protection, safe overload and ultimate overload are split by capacity (see the specifications section).

What is it, and how does it relate to HY-SBD?

Short answer: the photograph shows the same double shear beam structure as HY-SBD (beam body, black mounting base, two load buttons), and the capacity range is identical (15 to 50 t). But the electrical parameters differ — this is not the same data sheet under a new name.

HY-QS vs HY-SBD, electrical parameters (both pages of documentation)
Item HY-QS (this page) HY-SBD
Capacity 15 to 50 t, 5 steps 15 to 50 t, 5 steps (same)
Input / output resistance 750±10 / 703±2 Ω 772±4 / 700±1 Ω
Operating range -30 to +70 °C -40 to +65 °C
Excitation (rec. / max) 10-12 V / 15 V 5-15 V / 20 V
Overload (safe / ultimate) split by capacity (see below) 150% / 300%
Protection IP67 (5 t) / IP68 (10-50 t) IP67
Cable 13 / 16 m 13 m

⚠️ Two points: ① the excitation window is narrow (10-12 V recommended, 15 V max) compared with HY-SBD's 5-15 / 20 V — an indicator set above 15 V will exceed it; ② the resistances differ (750/703 vs 772/700), so fault checks must not borrow the other model's reference values.

What are the specifications? ⚠️ Three rows are split by capacity

Short answer: the company documentation gives 19 parameters, and three of them carry two values in one cell — safe overload, ultimate overload and protection. Both values are transcribed, with the capacity group the documentation names.

HY-QS specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-30 to +70
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ750±10
Output resistanceΩ703±2
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)10-12
Maximum excitationV (DC/AC)15
Safe overload%R.C.150; 120 (40-50 t)
Ultimate overload%R.C.300; 200 (40-50 t)
Protection—IP67 (5 t); IP68 (10-50 t)
Cable lengthm13 / 16

⚠️ Two things worth flagging: ① overload capacity drops at the 40-50 t steps (150%→120%, 300%→200%) — the high steps must not be sized with the margin of the low steps; ② the protection cell says "IP67 (5 t)" but the capacity list has no 5 t step (only 15-50 t). That is an inconsistency in the documentation; it is transcribed as written, and this page does not decide whether a 5 t version still exists. Ask us if you need one.

How is it wired?

Short answer: 4-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.

4-wire colour code (text and drawing agree)
Colour Terminal Function
Red+input+ excitation
Black−input− excitation
Green+output+ signal
White−output− signal
pale-yellowShieldShield (drawing only)

⚠️ Set the excitation for this model: 10-12 V recommended, 15 V max. Carrying over the 15 V-plus habit from other high-capacity models would exceed this one's limit. Earth the shield at one end only; at 13 m or 16 m this is a long 4-wire run, so assess the drop.

What are the dimensions?

Short answer: no dimensions are published — the documentation does not contain a dimension drawing for this model. Of the six images supplied, four are product photographs and two are wiring diagrams (duplicates); none carries dimension callouts.

What the documentation actually contains
Type Count Dimensions?
Product photographs4no
Wiring diagrams2 (duplicates)no
Dimension drawing0—

⚠️ Why not estimate: dimensions are used to drill base plates and mounting holes, and an estimated number moves the risk onto the customer. The field is left empty — ask us for the drawing of this model (number in the footer).

What does it look like?

Short answer: this page uses one product photograph and one wiring diagram. Three further photographs from the same angle and one duplicate diagram are omitted.

HY-QS double shear beam load cell: natural steel beam body on a black mounting base, two cylindrical load buttons on top, cable leaving one side; factory watermark
Product photograph (carries a factory watermark; not retouched). Company documentation.
HY-QS wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

⚠️ No dimension drawing exists for this model — all six supplied images are photographs or wiring diagrams.

Where does it fit, and where does it not?

Short answer: the documented applications are truck weighing and rail weighing, 15 to 50 t.

The platform types named above are the equipment the cell goes onto, as written in the documentation — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across red/black 750±10 Ω, output across green/white 703±2 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 750±10 Ω; open circuit means a broken internal wire
2 Measure green / white Around 703±2 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

⚠️ Do not borrow HY-SBD's references (772/700) — the resistances differ and the wrong reference will fail a good cell. On a parallel bank, disconnect the other cells before measuring one.

Where do the facts come from?

The protection row says "IP67 (5 t)" while the capacity list has no 5 t step; both are transcribed unchanged.

Still unsure which step fits?

Tell us: platform size and cell count, total capacity per cell, foundation type, distance to the indicator, what excitation voltage your indicator supplies (this model wants 10-12 V, max 15 V), and whether the site stands wet.

Call +86 183 5123 8137