What is it, and why does IP68 matter?
Short answer: a hygienic / washdown cell — stainless body plus a laser-welded seal, rated IP68. The documented applications are "stainless washdown scales" and process weighing in the chemical, food and pharmaceutical industries.
IP67 versus IP68: IP67 covers brief immersion; IP68 covers continuous immersion (depth and duration are set by the manufacturer). Where a line is washed down every shift and the floor stands wet, that difference is real.
| Model | Protection | Material |
|---|---|---|
| HY-SSH (this page) | IP68 | stainless steel, laser-welded |
| HY-SSP-IL | IP67 | stainless steel |
| HY-1022 / HY-1241 | IP67 (HY-1241 also states IP65 in one place — that page explains it) | laser-welded seal |
| HY-SBS / HY-SBT / HY-SQB | IP67 | alloy steel, nickel-plated |
⚠️ IP68 does not mean "submersible to any depth": the documentation says only "for harsh environments" and gives no depth or duration. For prolonged immersion or high-pressure jets, confirm against the actual duty rather than treating IP68 as unlimited.
How is it wired?
Short answer: 6-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| pale-yellow | shield | Shield |
⚠️ This model uses green = excitation+, white = signal+, red = signal− — close to some siblings but not identical. Never carry a colour over from another model; work from this page and the unit. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP68 |
| Cable length | m | 2.5 |
What are the dimensions?
Short answer: this model ships with two dimension drawings — one covering 50 to 500 kg, one for 1000 kg. Unlike siblings that use a single grouped table, these are two separate sheets. Units are not marked and none are added here.
| View | Values shown |
|---|---|
| Side | 38, 89, 3.78, 178 |
| Top | 8.8, 80.01, 157.4, 159, 25.4±0.1, 25; hole M8 |
| View | Values shown |
|---|---|
| Side / top | 2.78, 178, 20, 50, 20, 65, 82; holes 2-8.8 |
⚠️ Overall length is 178 on both, but the mounting holes differ (M8 on the 50-500 kg sheet, 2-8.8 twin holes on the 1000 kg sheet). Use the sheet that matches your capacity; the drawings are titled "SSH 50kg~500kg" and "SSH 1000kg".
What does it look like?
Short answer: six images are supplied — product photographs, one wiring diagram and two dimension sheets. This page uses one photograph plus three drawings.
⚠️ Archive note: these images sit in the "product photo" folder on the old site, but three are actually drawings. This page uses them by what they are.
Where does it fit, and where does it not?
Short answer: the documented applications are stainless washdown scales and process weighing in chemical, food and pharmaceutical plants, 50 to 1000 kg. What those three industries share: washdown, corrosion resistance, and hygiene.
- Fits: food, pharmaceutical and chemical process weighing; stainless washdown bench platforms; floors that stay wet.
- Why IP68: IP67 covers brief immersion only; IP68 covers continuous immersion. Where washdown is heavy, that is the real difference.
- ⚠️ Not "unlimited waterproofing": no depth or duration is documented. Prolonged immersion or high-pressure jets need separate confirmation.
- Capacity limit: 50 to 1000 kg. The 1000 kg step has different mounting holes from 50-500 kg.
- Not covered: dry duties where IP68 is unnecessary (HY-1241 or HY-SSP-IL suffice); small bench platforms (single point); vessel batching (column modules).
How can I tell whether the cell has failed?
Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
On a washdown cell, watch the insulation in particular — that is what IP68 buys. If it starts to fall, the seal is already compromised; catching it early beats chasing a drifting reading later.
Where do the facts come from?
- Company product documentation: four features (stainless, laser-welded IP68, compact, applications), 6-wire colour code, 6 capacity steps, 19 technical parameters.
- Company images (six): product photographs, one wiring diagram, two dimension sheets (50-500 kg and 1000 kg).
- Protection ratings across models: the other product pages on this site.
- Public technical literature: the difference between IP67 and IP68, washdown requirements in food and pharmaceutical plants.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: industry and cleaning method (washdown / immersion / high-pressure), the material and its corrosiveness, load per cell and cell count, mounting space, indicator model, and temperature range.