What is a weighing module, and where does it mount?
Short answer: a weighing module is a structural accessory for a load cell, made of a top plate, a base plate, the load cell, a load-bearing column and support bolts. (Public technical literature, "Selection and installation of weighing modules".)
On this model the physical form is: a base plate with mounting holes at the bottom; a shear-beam load cell with a stainless-steel body in the middle; a load head and top plate above; adjustable horizontal restraint bolts on the side; an alignment tool for setting the working position; and a cable leaving from the side of the load cell. (Drawings below; structure from company documentation.)
A module usually mounts at the lower part of the scale body (feet, pallet), or at the upper part of a vessel (the waist of a reactor, tank or hopper). All modules of one weighing system must sit in the same horizontal plane. (Public technical literature, "Selection and installation of weighing modules".)
The direction given in the company documentation for this model is "applications with horizontal impact force", such as conveyor-roller scales. Material entering and leaving, and conveyor start and stop, push the module sideways, so the structure carries adjustable horizontal restraint bolts that limit lateral movement while leaving the vertical load path free.
Where it sits in a weighing system
A weighing system is normally made of the indicator/controller, the junction box, the weighing modules and the cable. The module carries the load, the junction box sums the signals of several modules, the indicator displays and controls. (Company installation instructions.)
A group is normally 3 to 6 modules, up to 12. The foundation must meet the stiffness requirement and lie in one plane, or be adjustable to one plane, so that every module carries an even share. (Company installation instructions.)
How do HY-CW, HY-CWC and HY-CW-M differ?
Short answer: of the three, HY-CW and HY-CWC carry identical company documentation, word for word, with no difference stated; HY-CW-M is different — it is documented as nickel-plated alloy steel, with 6-wire connection (green = +excitation), and its documentation adds a protection rating. All three share the same capacity steps.
| Item | HY-CW (this model) | HY-CWC | HY-CW-M |
|---|---|---|---|
| Material (documented wording) | Stainless steel Company documentation | Stainless steel Company documentation | Nickel-plated alloy steel Company documentation |
| Wiring system | 4-wire: red = +excitation, black = −excitation, green = +signal, white = −signal Company documentation | 4-wire: same as above (red = +excitation) Company documentation | 6-wire: green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense Company documentation |
| Capacity steps | 0.5, 1, 2, 3, 5, 8, 10, 15, 20 t (9 steps) Company documentation | Same as this model (9 steps) Company documentation | Same as this model (9 steps) Company documentation |
| Main features (first 4) | High-quality load cell, high weighing accuracy; self-aligning load head that keeps the correct loading position and gives good repeatability; adjustable horizontal restraint bolts; alignment tool for the correct working position Company documentation | Identical word for word Company documentation | Identical word for word Company documentation |
| Main features (the material item) | Stainless steel Company documentation | Stainless steel Company documentation | Nickel-plated alloy steel Company documentation |
What the three differences mean in practice
- Material sets the environment. This model and HY-CWC are stainless steel; HY-CW-M is nickel-plated alloy steel. Stainless steel suits damp sites, washdown and corrosive atmospheres; a plated surface is a coating, so against aggressive media it still has to be checked against the actual conditions.
- The 4-wire / 6-wire difference is the sense pair. This model's 4 wires carry excitation and signal only. HY-CW-M adds +sense and −sense, which compensate the excitation drop along the cable; the longer the run, the more that pair is worth.
- Colour codes must not be copied across models. This 4-wire model is red = +excitation; HY-CW-M is green = +excitation. The colour-to-signal mapping is different. Quote the full suffix when ordering, and wire to that model's shipping documentation and to the diagram on the unit in hand.
- The difference between HY-CW and HY-CWC is not documented. The two texts are identical word for word, so no difference is invented here; if it matters, compare the shipping documentation of the two models.
Other models in the family are grouped on the products page.
What are the specifications, and where does each value come from?
Short answer: the table lists each value of HY-CW with its source, and the right-hand column says what that value determines. Values are transcribed — not converted, not merged, and no step or item is added. This documentation page states no protection rating and gives no overall accuracy or long-term stability figure, so none of those are filled in here.
| Parameter | Value (with source) | What it determines |
|---|---|---|
| Model | HY-CW Company documentation | The identifier used for ordering. HY-CW and HY-CWC carry identical text with no stated difference, so always quote the full suffix and confirm against the shipping documentation of the model. |
| Category | Weighing module Company documentation | It is a structural part plus a load cell. Capacity, material and mounting dimensions have to be read together; comparing load cell figures alone is not enough. |
| Capacity steps | 0.5, 1, 2, 3, 5, 8, 10, 15, 20 t Company documentation (9 steps, transcribed) | The load ceiling per module. Total system capacity is rated capacity × number of modules, so calculate vessel dead weight plus product weight first, then take the next step up. |
| Material | Stainless steel Company documentation | What environment it can be used in: a stainless-steel body is one prerequisite for damp workshops that need washdown. For harsher conditions (aggressive media, high temperature) the documentation gives no rating, so check against the actual conditions. HY-CW-M in the same family is nickel-plated alloy steel and must not be treated as stainless steel. |
| Structural features | High-quality load cell, high weighing accuracy; self-aligning load head that keeps the correct loading position and gives good repeatability; adjustable horizontal restraint bolts; alignment tool for the correct working position; simple and quick installation; easy maintenance, saving downtime Company documentation | The self-aligning load head is what returns the loading position by itself, and it affects repeatability — whether repeated weighing of the same batch gives a tight or a scattered reading. The adjustable horizontal restraint bolts set how much lateral movement is held, which is the key part against horizontal impact. The alignment tool decides how quickly a module finds its correct position during installation. In practice, check verticality and restraint clearance against the installation table below after mounting. |
| Wiring system | 4-wire (+excitation / −excitation / +signal / −signal) Company documentation | Four wires carry excitation and signal only, with no sense pair. With a short run from module to indicator and enough conductor cross-section, the excitation drop is small and 4 wires are sufficient; on long runs the voltage drop has to be assessed, or a 6-wire model with sense wires chosen (HY-CW-M in the same family is 6-wire). |
| Colour code | Red = +excitation; black = −excitation; green = +signal; white = −signal (4 wires) Company documentation | The field wiring reference. This model is red = +excitation, while HY-CW-M in the family is green = +excitation — the colour-to-signal mapping is not the same, so colours must not be copied across models. Before wiring, use the shipping documentation and the diagram on the unit. |
| Wiring diagram (with shield) | Red = excitation(+); green = signal(+); black = excitation(−); white = signal(−); pale-yellow = shield Company specification drawing | The diagram adds one wire that the product text does not mention: the shield (pale-yellow). The shield goes to the shield terminal of the indicator or junction box and is earthed at one end only — earthing both ends creates a ground loop and brings interference in instead of keeping it out. This is the item most often missed when wiring from the product text alone. |
| Outline dimensions | Two dimension drawings are supplied, but they carry letter codes only (A / A1 / B / B1 / C / C1 / H / H1 / H2 / L / L1 / L2 / T / 3-D / 4-ΦP / 4-ΦQ), with no values Company specification drawing | Foundation layout and foot positions — but this page cannot give the numbers: the letters have to be read against a dimension table for each capacity step, and no such table is supplied. Confirm against the shipping documentation before installation; do not read values into the lettered drawing. |
| Documented applications | For weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales Company documentation (verbatim) | This is a direction (horizontal impact force), not a claim that every such machine is covered. For a specific machine, check vessel dead weight, product weight, number of feet and site conditions. |
The table has 10 rows. Values and wording are transcribed from company documentation; wherever this page explains something, the explanation is sourced separately and comes from public technical literature, not from a company commitment. The company documentation gives no protection rating for this model (only HY-CW-M in the family has a protection statement) and no overall accuracy or long-term stability figure; this page leaves those empty rather than borrowing values from a family model.
One more point: the company documentation says "high weighing accuracy". That is qualitative — no figure is given. This page transcribes the wording and does not convert it into a "±0.0X%" style number, and does not derive a class from it.
What drawings are available, and why are there no photographs?
Short answer: the company documentation for this model holds 6 images: 2 photographs (nameplate information could not be read clearly, so they were not used under the image rules) and 4 drawings (wiring diagram, end-view dimension drawing, side-view dimension drawing, mounting arrangement). All 4 drawings are used on this page. That is why there is no photograph here, only drawings.
Image note: all 4 drawings are used unaltered and each carries a pale Hengyuan watermark. Why the two photographs were not used: the nameplate information on them could not be read, even enlarged, so it could not be confirmed whether what the nameplate states is suitable for publication; under the image rules both are left out and not referenced. Where an image and the written documentation disagree, the written documentation governs.
Which value applies in which situation?
Short answer: check the capacity step with "dead load + live load ≤ rated capacity × number of modules × 70%" and take the next step up; take one module per support point; choose the material by the site environment (stainless steel or nickel-plated alloy steel); choose the wiring by distance (4-wire or 6-wire). (Criteria from public technical literature.)
dead load + live load ≤ rated capacity × number of modules × 70%
The same formula in words: dead load plus live load must not exceed rated capacity times the number of modules times 70 percent. Worked examples are on the Selection & Resources page.
| Your situation | What to take | Basis |
|---|---|---|
| The vessel already has support feet | One module per foot: 3 feet, 3 modules; 4 feet, 4 modules | Public technical literature |
| The calculated per-module load falls between two steps | Take the next step up, not down | Public technical literature |
| How many to buy, and how the set is arranged | Within one system use one fixed, one semi-floating and the rest floating; sets are normally three or four modules | Public technical literature |
| The machine applies horizontal impact (e.g. a conveyor-roller scale) | This model is documented for exactly this case; fit the adjustable horizontal restraint bolts as shown on the mounting arrangement and keep the restraint clearance the drawing calls for | Company documentation + company specification drawing |
| The site is damp and needs washdown | Take this model (stainless steel) rather than the nickel-plated alloy steel family model — but the company documentation gives no protection rating for this model, so cable entries and the junction box have to be checked separately | Material from company documentation; protection rating not stated |
| The module is far from the indicator | This model is 4-wire with no sense pair: check conductor cross-section and voltage drop first; if compensation is needed, consider the 6-wire family model (HY-CW-M) or confirm against the shipping documentation | Public technical literature on what sense wires do |
| Replacing an old module without changing the foundation | The two dimension drawings carry letter codes with no values, so measure the existing hole pattern and the available height, then confirm against the shipping documentation; do not read values into the lettered drawing | No dimension table supplied in company documentation |
Where does it fit, and where does it not?
Short answer: what the company documentation and the sourced content on this page can support is weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales, plus the damp environment that stainless steel is chosen for. Items the documentation does not give — protection rating, accuracy and long-term stability figures, material grade, temperature range, corrosion rating, dimension values — are not inferred here, and no conclusion is drawn on a customer's behalf.
Fit (with a source)
- Weighing where horizontal impact occurs: the company documentation says, verbatim, "for weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales". (Company documentation.)
- Machines that need restraint and a self-returning loading position: this model has adjustable horizontal restraint bolts and a self-aligning load head. (Company documentation.)
- Damp workshops that need washdown: the basis is the stainless-steel material; this model has no protection rating statement, so cable entries and the junction box must be checked separately. (Material from company documentation.)
- Replacing old modules on existing equipment: a weighing module mounts easily on vessels of almost any shape, which makes it suitable for retrofits. (Public technical literature, "Selection and installation of weighing modules".)
- Turning a vessel into a weighing system: tank, hopper or reactor, once fitted with weighing modules and an indicator, becomes a weighing system. (Public technical literature, "Selection and installation of weighing modules".)
Boundaries and non-fit (read these too)
- No protection rating on this model: this documentation page does not give one, and no value is borrowed from a family model; if a rating is required, check it against the conditions and the shipping documentation. (Not recorded in company documentation.)
- No dimension values on this model: the two dimension drawings carry letter codes only, and no matching dimension table is provided. (Company specification drawing.)
- Do not guess from the suffix what separates HY-CW from HY-CWC: the two texts are identical word for word, with no difference stated. (Company documentation.)
- Do not wire this model as 6-wire: it is 4-wire; 6-wire is how its family model HY-CW-M is wired, and the colour-to-signal mapping differs. (Company documentation.)
- Never mix capacities within one weighing system: check module capacity before mounting. (Company installation instructions.)
- No welding current through the load cell: no other current, welding included, may pass through the module or the load cell. (Company installation instructions.)
- Untreated product piping spoils the reading: run every pipe connected to the vessel horizontally so it cannot hang the vessel, and use flexible connections wherever possible. (Public technical literature, "Selection and installation of weighing modules".)
How is it installed and wired?
Short answer: three things decide whether a module works — base stiffness and level, the verticality of module to mounting face, and whether bypass loads such as piping and welding have been removed. This model adds two parts of its own: the adjustable horizontal restraint bolts (fitted as shown on the mounting arrangement) and the alignment tool (which sets the working position).
| Item | Requirement | Source |
|---|---|---|
| Verticality | The vertical axis of every module must match the perpendicular to the mounting plate, deviation no more than 1.5°; correct any uneven or out-of-square condition with shims | Company installation instructions |
| Frame and base stiffness | The frame and base plate carrying the modules must be rigid enough; stiffness must reach 1/1000 | Company installation instructions |
| Upper and lower mounting faces | Top and bottom mounting faces of every module fully in contact, with no unevenness, and evenly loaded | Company installation instructions |
| Levelling | After mounting three or four modules under the vessel feet or brackets, rock the top plate by hand; if it moves, the module is not level — shim with steel plate until it no longer moves | Company installation instructions |
| Bolting | Tighten all bolts diagonally: pre-tighten first, then torque to specification | Company installation instructions |
| Fixing method | Once the module is level, either bolt it (top plate to the vessel foot or bracket, base plate to the steelwork or floor) or weld it — and while welding, no current may pass through the module | Company installation instructions |
| Welding | No other current (welding, for example) may pass through the load cell; it will damage the cell | Company installation instructions |
| Cable | Do not pull the cable tight, or the tension affects the electrical performance; protect the cable from cuts and abrasion | Company installation instructions |
| Handling | Never lift the module by its cable when taking it out of the packing; avoid knocks and do not let it fall from height | Company installation instructions |
| Module capacity | Check module capacity before mounting; never install modules of different capacities in one weighing system | Company installation instructions |
| Wiring and re-check | Wire the load cell cables to the junction box as the diagram requires; complete the run from junction box to indicator; re-check every connection; verify the supply voltage | Company installation instructions |
| Horizontal restraint | Fit the end restraint bolts and side restraint bolts as shown on the mounting arrangement; this model has adjustable horizontal restraint bolts, so check the restraint clearance against the drawing after mounting | Company documentation + company specification drawing |
| Bracket skew | Skew of the upper bracket to the horizontal must not exceed 0.5°; twist or skew of the base bracket to the horizontal must not exceed 0.5° | Public technical literature, "Selection and installation of weighing modules" |
| Foundation | The foundation (or floor) carrying the vessel must have enough load capacity and stiffness, with deflection below 3 mm; a concrete foundation is the better choice | Public technical literature, "Selection and installation of weighing modules" |
| Piping | Run every pipe connected to the vessel horizontally so it cannot hang the vessel; put the first pipe support as far from the vessel as practical; use flexible connections wherever possible | Public technical literature, "Selection and installation of weighing modules" |
| Independent load path | The vessel must act on the load cells alone; no mechanical tie to any part that the cells do not carry | Public technical literature, "Selection and installation of weighing modules" |
| Earthing | One independent earth per module | Public technical literature, "Selection and installation of weighing modules" |
| Service access | Mount the modules where they can be reached for maintenance | Public technical literature, "Selection and installation of weighing modules" |
| Calibration conditions | Allow for test-weight positions and jacking points at the design stage; calibration is required after installation | Public technical literature, "Selection and installation of weighing modules" |
The table lists the general requirements of the company installation instructions and of public technical literature, which apply to this type of module; site practice and the final decision still rest on the shipping documentation and the actual conditions. Wire to this model's 4-wire colour code and the wiring diagram (shield included, earthed at one end only); for the indicator side, see the FAQ.
Where do the facts come from?
- Company product documentation (HY-CW product page text): model, category, capacity steps, stainless steel, structural features (self-aligning load head / adjustable horizontal restraint bolts / alignment tool), 4-wire connection and colour code, the documented application; plus the material behind the three-model table above.
- Company specification drawings: wiring diagram (shield included), end-view and side-view dimension drawings (letter codes), mounting arrangement (end and side restraint bolts).
- Company installation instructions: composition of a module and of a weighing system, module count and foundation requirements, installation tolerances and stiffness, fixing and welding prohibitions, cable and wiring requirements.
- Public technical literature ("Selection and installation of weighing modules" and similar): module construction, sizing and module count, piping and calibration requirements, static and dynamic load criteria, what sense wires do on a 6-wire module.
Values in the tables are the company's own documented values and are not a commitment for a specific project; confirm the specification against the application. This model's documentation gives no protection rating and no dimension values, so the shipping documentation governs.
Still unsure which capacity step fits?
Send these in one go and we can suggest capacity and module count directly: equipment type (tank / platform / conveyor-roller scale), vessel dead weight, product weight, number and layout of support feet, product name and characteristics, site environment, distance from module to indicator, and whether it is a new build or a retrofit. Quote the full model suffix when ordering.