HY-CWC Weighing Module: 0.5 t to 20 t, 9 Steps, 4-Wire with Shield, Dynamic Load

HY-CWC is a dynamic-load weighing module: the load cell, top plate, base plate, load-bearing column and support bolts are built into one unit that mounts on machinery carrying horizontal impact, and turns weight into a signal for the weight indicator, for process weighing and weighing control.

If you are unsure which capacity step fits, describe the application:

+86 183 5123 8137

Short answer: HY-CWC covers 0.5, 1, 2, 3, 5, 8, 10, 15 and 20 t in 9 steps; the material is quality stainless steel; the connection is 4-wire plus shield, and the colour code is split into two capacity ranges (0.5–3 t and 8–20 t, with the excitation and signal colours reversed). It is a dynamic-load module, and with the HY-CWC-M static-load module it forms a pair from the same family with different suffixes, different wiring and different applications. Every value is transcribed from company product documentation and sourced row by row.

Values are transcribed from company product documentation; each row of the specification table carries its own source.

What is a weighing module, and where does HY-CWC mount?

Short answer: a weighing module is a structural accessory for a load cell, made up of a top plate, a base plate, the load cell, a load-bearing column and support bolts; it combines the load cell, the load transfer parts and the mounting plates into one component. (Public technical literature, Weighing Module Selection and Installation.)

The module normally mounts at the lower part of the scale body (feet, platform), and may also mount on the upper part of the body (the waist of a reactor, tank or hopper); all modules of one weighing system must sit in the same horizontal plane. (Public technical literature, same source.)

That is the difference from buying a bare load cell: a module integrates the cell, the force-taking structure and the mounting connection, so it takes load as soon as the foot is fitted, and part of the error caused by poor mounting is absorbed by the structure itself; a bare cell leaves the force point, the restraint and the mounting face to the installer. (Public technical literature, same source.)

The documented application for this model, transcribed: suitable for weighing and process weighing control in applications with horizontal impact, such as roller conveyor scales. (Company product documentation.)

Where it sits in a weighing system

Modules connect readily to machines of many shapes — conveyors, platforms, vertical tanks, tanks, hoppers — to form weighing control systems. Such a system normally consists of an indicator, a junction box, the weighing modules and cable. (Company installation instructions.)

Module type and size are chosen for the duty. A weighing system usually takes 3 to 6 sets of modules, 12 at most; the foundation carrying them must meet the stiffness requirement and must be in one plane, or adjustable into one plane, so that every module carries an even share of the load. (Company installation instructions.)

HY-CWC or HY-CWC-M: which one, and why can the wiring colours not be copied between them?

Short answer: check whether the site gives the module horizontal impact. Product delivered horizontally onto the scale body or into a vessel creates horizontal impact, and a dynamic-load module is the right choice; product delivered vertically by conveyor or pump into a hopper, tank or reactor calls for a static-load module. HY-CWC is the dynamic-load module and HY-CWC-M is the static-load member; each has its own wiring system and colour definitions, and neither set may be used on the other model. (Criterion from public technical literature, Weighing Module Selection and Installation.)

The documented application for this model — suitable for weighing and process weighing control in applications with horizontal impact, such as roller conveyor scales — matches that criterion. (Company product documentation.)

The two models side by side

HY-CWC and HY-CWC-M: application and wiring
Item HY-CWC (this page) HY-CWC-M
Load type Dynamic-load module, takes horizontal impact Static-load module
Typical application Weighing and process weighing control where horizontal impact occurs, such as roller conveyor scales; product delivered horizontally onto the scale body or into the vessel Hoppers, tanks, reactors and vessels fed vertically by conveyor or pump; batching under vessel feet or brackets
Wiring system 4-wire plus shield (+excitation / −excitation / +signal / −signal, plus 1 shield wire) 6-wire (a +sense / −sense pair in addition to the 4 wires)
Colour code Two sets by capacity range: 0.5–3 t and 8–20 t, with the excitation and signal colours reversed (see the colour-code row of the specification table) Green +excitation; black −excitation; white +signal; red −signal; yellow +sense; blue −sense. Letters and colours differ from HY-CWC and are not interchangeable
Parts specific to this model Adjustable horizontal restraint bolts; alignment tool Spherical joint; support bolts

Wiring and application detail for HY-CWC-M is on the HY-CWC-M page; general selection questions are covered on the Selection & Resources page.

Why colours and wire order cannot be copied across models

What are the specifications, and where does each value come from?

Short answer: the table below lists the documented values for HY-CWC, row by row, with the source; the right-hand column translates each parameter into what it decides at selection and installation. Values are transcribed as given — not converted, not merged, and not extended with steps the documentation does not list.

HY-CWC specifications, sources, and what each value determines
Parameter Value (source) What it determines
Model HY-CWC Company documentation Ordering reference. The family also has static-load models ending in -M, with different wiring systems and colour definitions, so quote the full suffix.
Category Weighing module Company documentation A structural part plus a load cell; capacity, material and mounting dimensions all belong to the selection, so it is not enough to match load cell figures.
Capacity steps 0.5, 1, 2, 3, 5, 8, 10, 15, 20 t Company documentation, 9 steps, transcribed The maximum load per module. System capacity is rated capacity × number of modules; the step also decides which colour set applies (0.5–3 t or 8–20 t), so capacity is not only "how big a scale" but also which wiring table to read.
Material Quality stainless steel Company documentation Decides where it can be used. For long exposure to damp or corrosive media, public technical literature advises full stainless steel modules. (Basis: Weighing Module Selection and Installation.)
Combined accuracy The company documentation states only "quality load cells, high weighing accuracy"; no figure is given Company documentation The documentation gives a qualitative statement and no figure, so this page gives no accuracy grade and makes no conversion. Where a quantitative figure is needed, check it against the application and the indicator.
Structural features Self-aligning load head that keeps the load application point correct and gives good repeatability; adjustable horizontal restraint bolts; alignment tool to set the working position; simple and quick installation; easy maintenance, less downtime Company documentation The load head decides whether the load point returns to position under eccentric load; the restraint bolts and the alignment tool decide whether the module can be set straight on site and locked there. On site, check all three: load head, restraint bolts, alignment tool, fitted as the shipping documentation requires.
Wiring system 4-wire plus shield (+excitation / −excitation / +signal / −signal, plus 1 shield wire) Company installation instructions 4 wires means two for excitation and two for signal; the shield suppresses interference from drives and power cable, earthed at one end, with the signal cable kept away from power cable. There is no sense pair, so no feedback compensation is available on long runs: the longer the run to the indicator, the more the cable specification must be checked against the shipping documentation.
Colour code Split by capacity range:
① HY-CWC-0.5~3t: green = EXC+ (excitation+); black = EXC− (excitation−); white = SIG+ (signal+); red = SIG− (signal−); yellow = SHLD (shield).
② HY-CWC-8~20t: red = EXC+ (excitation+); black = EXC− (excitation−); green = SIG+ (signal+); white = SIG− (signal−); yellow = SHLD (shield).
The shield is yellow in both sets, and the excitation and signal colours are exactly reversed between them.
The company product page lists 4 wires only (red = +excitation, black = −excitation, green = +signal, white = −signal), which matches the 8–20 t set; it does not list the shield and does not mention the reversed 0.5–3 t set.
This page follows the company installation instructions and gives both sets; the shipping documentation and the drawing on the unit govern in every case. Company installation instructions
The field wiring reference. Two things come first: confirm which capacity range is in hand (0.5–3 t or 8–20 t) — the excitation and signal colours are reversed between them, so the wrong set puts excitation on signal; then land the shield separately (yellow), earthed at one end. This is also why colours must not be copied across models: the letters, the colours and the wire count all differ from HY-CWC-M.
Documented applications Weighing and process weighing control in applications with horizontal impact, such as roller conveyor scales Company documentation A direction of use, not a claim of suitability for every weighing job; for a specific machine, check horizontal impact, vessel dead weight, product weight, number of feet and site conditions.

Values and wording are transcribed from company documentation, including the fact that no figure is given where none is stated; each explanation carries its own source and is public technical literature, not a company commitment. The company documentation does not state the protection rating for this model. It gives no outline dimensions and no wiring diagram either, so none of the three is inferred and no inferred value is published here.

Which value applies in which application?

Short answer: size the capacity from "dead load + live load ≤ rated capacity × number of modules × 70%" and then take the next step up; take one module per actual support point; and let the presence of horizontal impact decide between this model and HY-CWC-M. (Criterion from public technical literature.)

dead load + live load ≤ rated capacity × number of modules × 70%

The formula is repeated in words so it can be copied into a design note, sent to a colleague or printed for a design office (public technical literature). Worked examples are on the Selection & Resources page.

Case by case (follow directly)

Which capacity step and how many modules: case by case
Your case What to take Basis
Product delivered horizontally onto the scale body or into the vessel Take a dynamic-load module, i.e. HY-CWC; do not substitute a static-load module Public technical literature, Weighing Module Selection and Installation
Product delivered vertically by conveyor or pump into a hopper, tank or reactor Take a static-load module, i.e. a module of the HY-CWC-M kind Public technical literature, Weighing Module Selection and Installation
The vessel already has support feet Take the number of modules from the number of feet: 3 feet, 3 modules; 4 feet, 4 modules Public technical literature
New vessel, vertical cylinder Three-point support is the more stable; where wind, sway or vibration matter, four-point support is preferable Public technical literature
The calculated capacity falls between two steps Take the next step up, never the one below Public technical literature
The calculated capacity falls between 3 t and 8 t, or the order crosses the two ranges Fix the step first, then the wiring table: 0.5–3 t uses the first colour set, 8–20 t the second; the two must not be mixed Colour sets from company installation instructions; step split from company product documentation
How many modules per set, and which structure One fixed and one semi-floating module per set, the rest full-floating; sets are commonly three modules for three-point support and four modules for four-point support Public technical literature
The modules must be easy to service Give each module its own independent earth; calibrate the system after installation Public technical literature
Damp site, or contact with corrosive media The material of this model is quality stainless steel, and the literature advises full stainless steel modules for long exposure to damp or corrosive media. The company documentation does not state the protection rating for this model, and no value is inferred here Material from company product documentation; advice from public technical literature
Horizontal impact on site, and the module must not be knocked out of position Use the adjustable horizontal restraint bolts and the alignment tool supplied with this model, and lock the module after setting it straight as the shipping installation instructions require Company product documentation and company installation instructions

Where does it fit, and where does it not?

Short answer: what the company product documentation and the sourced statements on this page support is weighing and process weighing control in applications with horizontal impact, such as roller conveyor scales, together with damp or corrosive surroundings as far as a stainless steel material goes; what the documentation does not give — protection rating, outline dimensions, wiring diagram — is not inferred here, and no conclusion is drawn on the customer's behalf.

Fits (documented)

Limits and does not fit (read these too)

What does the module look like, and what do the drawings show?

Short answer: image 1 is the product photo of this model; images 2 and 3 are company specification drawings — a five-panel mounting arrangement sketch and a three-point 120° layout drawing. The files are local, and the page loads no external resources. One product photo and two drawings are available for this model.

HY-CWC dynamic-load weighing module: top plate with mounting holes at the top, a shear-beam load cell in the middle, a base plate below, support and restraint bolts, and a cable leaving from the side
Product photo — HY-CWC dynamic-load weighing module: top plate with mounting holes, shear-beam load cell, base plate, support and restraint bolts, cable leaving from the side. Company documentation.
HY-CWC specification drawing: mounting arrangements, five panels each showing a different module layout and mounting attitude, line drawing only
Drawing 1 — mounting arrangements: five panels showing different module layouts and mounting attitudes; the drawing carries no text labels. Company specification drawing.
HY-CWC specification drawing: three-point 120 degree layout with the end restraint bolt and the lateral restraint bolt marked, with a light graphic watermark
Drawing 2 — three-point 120° layout: the end restraint bolt and the lateral restraint bolt are marked on the drawing; it carries a light graphic watermark. Company specification drawing.

The 1 product photo and the 2 specification drawings are company product images, used unaltered; the page loads no external image resources.

How is it installed and wired?

Short answer: whether the module goes in right depends on three things — base stiffness and level, verticality of the connection, and whether welding current and piping have been dealt with as paths that bypass the module. Every row below gives a value or an action that can be checked; sources are the shipping installation instructions and public technical literature.

HY-CWC installation and wiring requirements, row by row with source
Item Requirement Source
Verticality The vertical axis of every module must align with the perpendicular to the mounting plate, deviation not more than 1.5°; correct unevenness or tilt with shims or similar Company installation instructions
Frame and base plate stiffness The frame and base plate carrying the modules must be stiff enough; stiffness must reach 1/1000 Company installation instructions
Mounting faces Top and bottom mounting faces of every module fully in contact, with no unevenness, and evenly loaded Company installation instructions
Bracket skew Skew of the upper bracket to horizontal must not exceed 0.5°; twist or skew of the base bracket to horizontal must not exceed 0.5° Public technical literature, Weighing Module Selection and Installation
Foundation The foundation (or floor) carrying the vessel must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is a good choice Public technical literature, Weighing Module Selection and Installation
Levelling After mounting 3 or 4 modules under the vessel feet or brackets, rock the top plate by hand: if it moves, the module is not level, and shims must be added until it no longer moves Company installation instructions
Bolting Tighten every bolt diagonally, pre-tighten first, then torque to specification Company installation instructions
Fixing method Two options after levelling: ① bolted — top plate to the vessel foot or bracket, base plate to the steelwork or floor; ② welded — top plate to the vessel foot, base plate to the steelwork, with no current through the module during welding Company installation instructions
Welding No other current (arc welding or similar) may pass through the load cell, or the cell will be damaged Company installation instructions
Cable Do not tension the cable, so that no pull reaches the electrical properties; protect the cable and keep it free of cuts and abrasion Company installation instructions
Handling While unpacking or mounting, never lift the module by its cable; avoid knocks and prevent the module from falling from height Company installation instructions
Piping Run every pipe connected to the vessel horizontally so no pipe hangs the vessel; place the first pipe support as far from the vessel as possible; use flexible connections where possible Public technical literature, Weighing Module Selection and Installation
Wiring and power-up Connect the load cell cable to the junction box as the wiring drawing requires; complete the run from the junction box to the indicator; re-check every terminal and check that the supply voltage is correct; the far end lands on the terminals of the junction box and the terminal board Company installation instructions
Colour code Pick the table by capacity range: 0.5–3 t uses green = excitation+, black = excitation−, white = signal+, red = signal−; 8–20 t uses red = excitation+, black = excitation−, green = signal+, white = signal−; the shield is yellow in both. Do not interchange these with the colour definitions of HY-CWC-M Company installation instructions
Pre-installation check Check the capacity of each module before mounting; never use modules of different capacity in one weighing system Company installation instructions
Header cable Set the length of the header cable from the site layout Company installation instructions
Calibration conditions Allow, at the design stage, for positions to place test weights during calibration and for jacking points during installation and service; the system must be calibrated after installation Public technical literature, Weighing Module Selection and Installation

Unless marked otherwise, the rows above come from the shipping installation instructions for this model and from public technical literature; site practice and the final decision remain with the shipping documentation and the actual conditions. Calibration steps at the indicator are covered on the FAQ page.

Where do the facts come from?

Values in the tables are transcribed from company documentation and are not a commitment for a specific project; final specifications are confirmed against the application. First published: 2026-10-24.

Still unsure which capacity step fits?

Give us these in one go and we can suggest the capacity step and the number of modules directly: vessel dead weight, product weight, number and layout of support feet, whether product enters horizontally or drops vertically, site conditions, and whether it is a new build or a retrofit.