First published · Chinese version: HY-FW 称重模块

You are here: Home > Products > HY-FW

HY-FW Weighing Module: 0.5 t to 20 t in 9 Steps, Alloy Steel, Nickel-Plated

HY-FW is a weighing module with nine capacity steps from 0.5 t to 20 t. The module combines the load cell with a top plate, a base plate, a load-bearing support column and support bolts; it mounts under the feet or brackets of a tank, vessel or silo and turns weight into an electrical signal for the weight indicator, for weighing control in a batching process. The company documentation states the application as “suitable for weighing control in the batching process of tanks”.

If you cannot tell which step fits, describe the duty:

+86 183 5123 8137

Short answer: HY-FW covers 0.5, 1, 2, 3, 5, 8, 10, 15 and 20 t in nine steps; the body and load-bearing parts are alloy steel, nickel-plated; connection is 4-wire with shield; outline dimensions come in four steps (0.5–3 t / 5–8 t / 10 t / 15–20 t) and are given as two dimensioned drawings, side view and end view, plus a step dimension table with 15 labels. All values are transcribed from company documentation, with the source marked row by row.

Values are transcribed from company documentation; every field in the tables below carries its source.

What is HY-FW and where does it mount?

Short answer: a weighing module is a structural accessory for a load cell, built from a top plate, a base plate, the load cell, a load-bearing support column and support bolts; it puts the load cell, the load-transfer parts and the mounting plates into one unit. (Public technical literature, “Selection and installation of weighing modules”.)

Modules normally sit under the scale body — feet, platform — and can also sit on the upper part of it, on the waist of a kettle, tank or hopper. All modules of one weighing system must be in the same horizontal plane. (Same source.)

The company documentation gives two structural statements for this model: the structure is unique, and the module mounts easily on all kinds of tanks; support bolts prevent the equipment from tipping over. The matching installation step is to fit the module under the tank foot or bracket, then fix module and foot together with the support bolts. (Company documentation.)

What are the three structures, and which one is HY-FW?

By public industry documentation: depending on the load-bearing support column and top plate, weighing modules are classed as fixed, semi-floating and full-floating. One system uses one fixed module and one semi-floating module, with the rest full-floating; sets are usually three modules for three-point support and four modules for four-point support. (Public technical literature.)

The company documentation does not state which of the three structures this model is, so this page does not classify it. How the three structures divide the work, and how to tell them apart, is set out on the fixed weighing module page; where the structure matters for selection, use that page and the shipping documentation of the actual unit.

Where does it sit in a weighing system?

A weighing system is normally made of a weight indicator, a junction box, the weighing modules and cable; the module carries the load, the junction box sums the signals of several modules, and the indicator displays and controls. (Company installation instructions.)

A group normally uses 3 to 6 modules (up to 12); the foundation must meet the stiffness requirement and sit in one horizontal plane, or be adjustable to it, so that every module carries an equal share. (Company installation instructions.)

What are the specifications, and where does each value come from?

Short answer: the table below lists each documented value with its source, and the right-hand column translates the value into what it decides at selection and installation. Values are transcribed as they stand — no conversion, no merging, and no capacity step that the documentation does not list.

HY-FW specifications, their sources, and what each value determines
Parameter Value (source) What it determines
Model HY-FW Company documentation The ordering reference. The series also has models ending in other suffixes; quote the full suffix and use the shipping documentation of the unit.
Category Weighing module Company documentation It is a structural part plus a load cell, so capacity, material and mounting dimensions are judged together — load cell data alone is not enough.
Capacity steps 0.5, 1, 2, 3, 5, 8, 10, 15, 20 t Company documentation (9 steps, transcribed verbatim) The maximum load per module. System capacity is rated capacity × number of modules, so work out the load first, then take the next step up.
Material and surface finish Alloy steel, nickel-plated Company documentation The material and surface state of the housing and load-bearing parts: alloy steel parts with a nickel-plated surface. Where humidity, washdown, corrosive media or temperature add requirements, check them against the actual conditions and the shipping documentation.
Overall accuracy The company documentation says only “uses high-quality load cells, high weighing accuracy”; it gives no figure Company documentation The documentation is qualitative only, so this page gives no figure and does no conversion. For a number, check the application and the indicator used together.
Structural features Unique structure, mounting easily on all kinds of tanks; support bolts preventing the equipment from tipping over; simple, quick installation; easy maintenance, saving downtime Company documentation “Mounting easily on all kinds of tanks” is the answer to how far the module adapts to foot shapes; “support bolts preventing tipping” means room must be left for fixing and adjusting them; “easy maintenance” means service space below the foot. In practice, measure the existing foot holes and the available height first, then pick the step against the dimension drawings.
Wiring 4-wire + shield (+excitation / −excitation / +signal / −signal, plus one shield wire) Company documentation and specification drawing How many cores run from the module to the junction box, and how many terminals to allow. A 4-wire module has no +sense / −sense pair, so on a long run the excitation drop in the cable cannot be compensated through a feedback pair; the shield suppresses interference from drives and power cables — single-ended earth, signal cable kept away from power cable. (Practice from public technical literature.)
Colour code Red = +excitation; black = −excitation; green = +signal; white = −signal (4 cores). The wiring schematic on the specification drawing adds light yellow = shield Company documentation and specification drawing The field reference for termination. Colour codes are not common across models or batches, so wire to the shipping documentation and the wiring diagram of the unit in hand; do not copy colours across models.
Wiring schematic Red = excitation+; green = signal+; black = excitation−; white = signal−; light yellow = shield Company specification drawing (drawing 3 below) One shield wire more than the text rows above; termination and order follow this drawing. Check the terminal numbers against the drawing before power-up.
Outline dimensions Four steps by capacity (0.5–3 t / 5–8 t / 10 t / 15–20 t); two dimensioned drawings, side view and end view, plus a step dimension table, 15 labels in all: L, L1, L2, A, A1, B, B1, C, C1, H, H1, H2, ØG, ØP, T Company specification drawings (drawings 4, 5 and 6 below) Changing the capacity step changes the outline and the hole positions — capacity is not one number alone, it moves the foot positions and the foundation size. Fix the capacity step before altering the feet or casting the foundation, then check the hole pitch and overall height of that step against the space available. The values themselves are on the drawing, which carries no unit; they are transcribed as they stand.
Documented application Suitable for weighing control in the batching process of tanks Company documentation A direction as to where it is used, not a claim that every tank application fits; for a given unit, check vessel dead weight, product weight, number of feet and site conditions.

Eleven rows, one per field recorded in the company documentation. Values and wording are transcribed as they stand, including the fact that no figure is given where none is given; explanations are marked as public technical literature, not as a company commitment. The company documentation gives no protection rating and no long-term stability statement for this model, so neither is inferred here.

Which capacity step fits which duty?

Short answer: check the single-module rating against dead load + live load ≤ rated capacity × number of modules × 70%, then take the next step up; the number of modules follows the number of support points. (Criterion from public technical literature.)

dead load + live load ≤ rated capacity × number of modules × 70%

The formula is repeated here as a single line so it can be copied, sent to a design office or printed. Worked examples are on the Selection & Resources page.

Case by case

Which step to take and how many modules to fit
Your case How to take it Basis
The vessel already has support feet Set the module count from the number of feet: 3 feet, 3 modules; 4 feet, 4 modules Public technical literature
The calculated single-module capacity falls between two steps Take the next step up, not down Public technical literature
How many to buy per set, and how to arrange the structures One fixed module and one semi-floating module per system, the rest full-floating; three-module and four-module sets are the common ones Public technical literature
Product is fed into the vessel horizontally Horizontal feed produces horizontal impact, so a dynamic-load module is the one to use; with vertical feed, a static-load module Public technical literature
Vessel and product are both heavy and fewer modules are wanted Work out the single-module rating at the 70% basis first, then set the count from the support points — the count follows the number and layout of the supports and cannot be replaced by a larger capacity Criterion from public technical literature

Where does it fit, and where does it not?

Short answer: what the company documentation and the sourced material on this page support is weighing control in the batching process of tanks, plus the case the public installation literature describes for dynamic-load modules where product enters a vessel horizontally. Items the company documentation does not give — protection rating, long-term stability, structure class, material grade, service temperature — are not inferred here, and no conclusion is drawn on the customer's behalf.

Fits, with a source

Limits and exclusions, just as important

What do the unit and the specification drawings show?

Short answer: the first two images are photographs of this model; the next six are company specification drawings — mounting arrangements, layout with the three structures, wiring schematic, side and end dimension drawings, and the step dimension table. All images are local files; the page loads no external resource.

HY-FW weighing module, front view: top plate above, base plate below, support bolts visible and the cable leaving from the side, product shot on a white background
Photo 1 — front view: top plate above, base plate below, cable leaving from the side, support bolts visible; the image carries a light watermark. Company product image.
HY-FW weighing module, close-up of the top plate showing a barcode label on the side of the load cell and the cable entry
Photo 2 — top plate close-up: a barcode label on the side of the load cell; the image carries a light watermark. Company product image.
HY-FW specification drawing 1: mounting arrangements, a five-panel line drawing of module layouts and mounting positions
Drawing 1 — mounting arrangements: five panels showing different module layouts and mounting positions. Company specification drawing.
HY-FW specification drawing 2: layout drawing with rectangular and radial layouts and the fixed, semi-floating and full-floating structures
Drawing 2 — layout: rectangular and radial layout (90° / 120°), with the fixed, semi-floating and full-floating structures sketched. The three structures are a general industry classification; the company documentation does not state which one this model is. Company specification drawing.
HY-FW specification drawing 3: 4-wire-with-shield wiring schematic marking excitation positive and negative, signal positive and negative, and the shield wire colours
Drawing 3 — wiring schematic: 4-wire + shield, red = excitation+, green = signal+, black = excitation−, white = signal−, light yellow = shield. Company specification drawing.
HY-FW specification drawing 4: side-view dimension drawing with letters and diameter symbols marking the dimensions
Drawing 4 — side view: labels A, A1, 4-ØG, H, T, L1, L2, L and 4-ØP. Values are in the dimension table below; the drawing carries no unit and is transcribed as it stands. Company specification drawing.
HY-FW specification drawing 5: end-view dimension drawing with letters marking height and width dimensions
Drawing 5 — end view: labels B, B1, H1, H2, C and C1. Values are in the dimension table below; the drawing carries no unit and is transcribed as it stands. Company specification drawing.
HY-FW specification drawing 6: step dimension table giving the dimension values for each of the four capacity steps
Drawing 6 — step dimension table: four steps by capacity (0.5–3 t / 5–8 t / 10 t / 15–20 t), each giving L, L1, L2, A, A1, B, B1, C, C1, H, H1, H2, ØG, ØP and T — 15 labels. The table carries no unit; the values are transcribed as they stand and are not copied again here. Company specification drawing.

All eight images are company product images used unaltered. Where an image and the written documentation disagree, the written documentation governs.

What matters during installation and wiring?

Short answer: three things decide whether the module works — the stiffness and level of the base, the verticality of the connections, and whether external load paths such as piping and welding have been removed. Each row below gives an action or a figure that can be checked; the source is public installation material.

Installation and wiring requirements, each with its source
Item Requirement Source
Verticality The vertical axis of every module lines up with the perpendicular to the mounting plate, deviation no more than 1.5°; correct with shims if it is out Company installation instructions
Frame and base plate stiffness The frame and base plate that carry the modules must be stiff enough; stiffness must reach 1/1000 Company installation instructions
Bracket skew Skew or twist of the upper bracket and the base bracket against horizontal must not exceed 0.5° Public technical literature
Foundation The foundation or floor carrying the tank must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is a good choice Public technical literature
Levelling After mounting, rock the top plate of the module by hand; if it moves, the module is not level — shim with steel plate until it no longer moves Company installation instructions
Bolting Tighten all bolts diagonally: pre-tighten first, then torque to specification Company installation instructions
Welding No current may pass through the weighing module during welding; no other current, such as welding current, may pass through the load cell Company installation instructions
Cable Do not pull the cable tight, or the tension affects the electrical properties; protect the cable from cuts and abrasion Company installation instructions
Handling Never lift the module by its cable; avoid knocks and do not let it fall from height Company installation instructions
Piping All pipes connected to the tank should run horizontally so they do not hang the tank; use flexible connections and put the first pipe support as far from the vessel as possible Public technical literature
Earthing Each module needs its own independent earth Public technical literature
Wiring and pre-power check Connect the load cell cable to the junction box as the wiring diagram requires; re-check the wiring for errors and check that the supply voltage is normal Company installation instructions
Calibration conditions At the vessel design stage allow positions for test weights during calibration and jacking points for installation and service; calibration is required after installation Public technical literature

The table lists general requirements from public installation material, applicable to this class of module; the site method and final acceptance rest on the shipping documentation and the actual duty. Indicator-side calibration steps are in the FAQ.

Where do the facts come from?

Parameter values are transcribed from company documentation and are not a commitment for a specific project; specifications are fixed against the actual duty. Dates and wording on this page follow the header and the footer.

Still unsure which step fits?

Tell us these in one go and we can suggest capacity and module count directly: tank dead weight, product weight, number and layout of support feet, product name and characteristics, site conditions, and whether it is a new build or a retrofit.

Call +86 183 5123 8137

HY-FWC-M and HY-FW-M belong to the same series. The documentation collected for this page covers HY-FW only; HY-FWC-M and HY-FW-M were not collected, so their parameters are not described here. Order by the full model suffix and use the shipping documentation of the unit.