What is HY-FW and where does it mount?
Short answer: a weighing module is a structural accessory for a load cell, built from a top plate, a base plate, the load cell, a load-bearing support column and support bolts; it puts the load cell, the load-transfer parts and the mounting plates into one unit. (Public technical literature, “Selection and installation of weighing modules”.)
Modules normally sit under the scale body — feet, platform — and can also sit on the upper part of it, on the waist of a kettle, tank or hopper. All modules of one weighing system must be in the same horizontal plane. (Same source.)
The company documentation gives two structural statements for this model: the structure is unique, and the module mounts easily on all kinds of tanks; support bolts prevent the equipment from tipping over. The matching installation step is to fit the module under the tank foot or bracket, then fix module and foot together with the support bolts. (Company documentation.)
What are the three structures, and which one is HY-FW?
By public industry documentation: depending on the load-bearing support column and top plate, weighing modules are classed as fixed, semi-floating and full-floating. One system uses one fixed module and one semi-floating module, with the rest full-floating; sets are usually three modules for three-point support and four modules for four-point support. (Public technical literature.)
The company documentation does not state which of the three structures this model is, so this page does not classify it. How the three structures divide the work, and how to tell them apart, is set out on the fixed weighing module page; where the structure matters for selection, use that page and the shipping documentation of the actual unit.
Where does it sit in a weighing system?
A weighing system is normally made of a weight indicator, a junction box, the weighing modules and cable; the module carries the load, the junction box sums the signals of several modules, and the indicator displays and controls. (Company installation instructions.)
A group normally uses 3 to 6 modules (up to 12); the foundation must meet the stiffness requirement and sit in one horizontal plane, or be adjustable to it, so that every module carries an equal share. (Company installation instructions.)
What are the specifications, and where does each value come from?
Short answer: the table below lists each documented value with its source, and the right-hand column translates the value into what it decides at selection and installation. Values are transcribed as they stand — no conversion, no merging, and no capacity step that the documentation does not list.
| Parameter | Value (source) | What it determines |
|---|---|---|
| Model | HY-FW Company documentation | The ordering reference. The series also has models ending in other suffixes; quote the full suffix and use the shipping documentation of the unit. |
| Category | Weighing module Company documentation | It is a structural part plus a load cell, so capacity, material and mounting dimensions are judged together — load cell data alone is not enough. |
| Capacity steps | 0.5, 1, 2, 3, 5, 8, 10, 15, 20 t Company documentation (9 steps, transcribed verbatim) | The maximum load per module. System capacity is rated capacity × number of modules, so work out the load first, then take the next step up. |
| Material and surface finish | Alloy steel, nickel-plated Company documentation | The material and surface state of the housing and load-bearing parts: alloy steel parts with a nickel-plated surface. Where humidity, washdown, corrosive media or temperature add requirements, check them against the actual conditions and the shipping documentation. |
| Overall accuracy | The company documentation says only “uses high-quality load cells, high weighing accuracy”; it gives no figure Company documentation | The documentation is qualitative only, so this page gives no figure and does no conversion. For a number, check the application and the indicator used together. |
| Structural features | Unique structure, mounting easily on all kinds of tanks; support bolts preventing the equipment from tipping over; simple, quick installation; easy maintenance, saving downtime Company documentation | “Mounting easily on all kinds of tanks” is the answer to how far the module adapts to foot shapes; “support bolts preventing tipping” means room must be left for fixing and adjusting them; “easy maintenance” means service space below the foot. In practice, measure the existing foot holes and the available height first, then pick the step against the dimension drawings. |
| Wiring | 4-wire + shield (+excitation / −excitation / +signal / −signal, plus one shield wire) Company documentation and specification drawing | How many cores run from the module to the junction box, and how many terminals to allow. A 4-wire module has no +sense / −sense pair, so on a long run the excitation drop in the cable cannot be compensated through a feedback pair; the shield suppresses interference from drives and power cables — single-ended earth, signal cable kept away from power cable. (Practice from public technical literature.) |
| Colour code | Red = +excitation; black = −excitation; green = +signal; white = −signal (4 cores). The wiring schematic on the specification drawing adds light yellow = shield Company documentation and specification drawing | The field reference for termination. Colour codes are not common across models or batches, so wire to the shipping documentation and the wiring diagram of the unit in hand; do not copy colours across models. |
| Wiring schematic | Red = excitation+; green = signal+; black = excitation−; white = signal−; light yellow = shield Company specification drawing (drawing 3 below) | One shield wire more than the text rows above; termination and order follow this drawing. Check the terminal numbers against the drawing before power-up. |
| Outline dimensions | Four steps by capacity (0.5–3 t / 5–8 t / 10 t / 15–20 t); two dimensioned drawings, side view and end view, plus a step dimension table, 15 labels in all: L, L1, L2, A, A1, B, B1, C, C1, H, H1, H2, ØG, ØP, T Company specification drawings (drawings 4, 5 and 6 below) | Changing the capacity step changes the outline and the hole positions — capacity is not one number alone, it moves the foot positions and the foundation size. Fix the capacity step before altering the feet or casting the foundation, then check the hole pitch and overall height of that step against the space available. The values themselves are on the drawing, which carries no unit; they are transcribed as they stand. |
| Documented application | Suitable for weighing control in the batching process of tanks Company documentation | A direction as to where it is used, not a claim that every tank application fits; for a given unit, check vessel dead weight, product weight, number of feet and site conditions. |
Eleven rows, one per field recorded in the company documentation. Values and wording are transcribed as they stand, including the fact that no figure is given where none is given; explanations are marked as public technical literature, not as a company commitment. The company documentation gives no protection rating and no long-term stability statement for this model, so neither is inferred here.
Which capacity step fits which duty?
Short answer: check the single-module rating against dead load + live load ≤ rated capacity × number of modules × 70%, then take the next step up; the number of modules follows the number of support points. (Criterion from public technical literature.)
dead load + live load ≤ rated capacity × number of modules × 70%
The formula is repeated here as a single line so it can be copied, sent to a design office or printed. Worked examples are on the Selection & Resources page.
Case by case
| Your case | How to take it | Basis |
|---|---|---|
| The vessel already has support feet | Set the module count from the number of feet: 3 feet, 3 modules; 4 feet, 4 modules | Public technical literature |
| The calculated single-module capacity falls between two steps | Take the next step up, not down | Public technical literature |
| How many to buy per set, and how to arrange the structures | One fixed module and one semi-floating module per system, the rest full-floating; three-module and four-module sets are the common ones | Public technical literature |
| Product is fed into the vessel horizontally | Horizontal feed produces horizontal impact, so a dynamic-load module is the one to use; with vertical feed, a static-load module | Public technical literature |
| Vessel and product are both heavy and fewer modules are wanted | Work out the single-module rating at the 70% basis first, then set the count from the support points — the count follows the number and layout of the supports and cannot be replaced by a larger capacity | Criterion from public technical literature |
Where does it fit, and where does it not?
Short answer: what the company documentation and the sourced material on this page support is weighing control in the batching process of tanks, plus the case the public installation literature describes for dynamic-load modules where product enters a vessel horizontally. Items the company documentation does not give — protection rating, long-term stability, structure class, material grade, service temperature — are not inferred here, and no conclusion is drawn on the customer's behalf.
Fits, with a source
- Weighing control in the batching process of tanks: the company documentation gives the application as “suitable for weighing control in the batching process of tanks”. (Company documentation.)
- Converting an existing vessel, hopper or reactor into a weighing system: the module mounts easily on vessels of various shapes, so existing equipment can be converted. (Public technical literature, “Selection and installation of weighing modules”.)
- Tank supports that need support bolts against tipping: based on the documented feature “support bolts, preventing the equipment from tipping over”. (Company documentation.)
- Product fed horizontally into the vessel, producing horizontal impact: where product is fed vertically into a hopper, tank, kettle or vessel by conveyor or pump, a static-load module is used; where it is fed horizontally onto the platform or into the vessel, the horizontal impact calls for a dynamic-load module. (Public technical literature.)
Limits and exclusions, just as important
- The company documentation gives no protection rating, long-term stability, structure class, material grade or service temperature: none of these is inferred here, and no value is published for them; where a value is needed, check it against the process and the site. (Basis: these fields are not recorded in the company documentation.)
- Never mix capacities within one weighing system. (Company installation instructions.)
- No welding current may pass through the load cell: current through the module during welding damages the cell. (Company installation instructions.)
- The vessel must not be mechanically tied to other parts that the modules do not carry, or the weighing result will be wrong. (Public technical literature.)
- Piping left unhandled makes calibration impossible: all pipes connected to the tank should run horizontally so that they do not hang the tank; the first pipe support should be as far from the vessel as possible, and flexible connections should be used. (Public technical literature.)
What do the unit and the specification drawings show?
Short answer: the first two images are photographs of this model; the next six are company specification drawings — mounting arrangements, layout with the three structures, wiring schematic, side and end dimension drawings, and the step dimension table. All images are local files; the page loads no external resource.
All eight images are company product images used unaltered. Where an image and the written documentation disagree, the written documentation governs.
What matters during installation and wiring?
Short answer: three things decide whether the module works — the stiffness and level of the base, the verticality of the connections, and whether external load paths such as piping and welding have been removed. Each row below gives an action or a figure that can be checked; the source is public installation material.
| Item | Requirement | Source |
|---|---|---|
| Verticality | The vertical axis of every module lines up with the perpendicular to the mounting plate, deviation no more than 1.5°; correct with shims if it is out | Company installation instructions |
| Frame and base plate stiffness | The frame and base plate that carry the modules must be stiff enough; stiffness must reach 1/1000 | Company installation instructions |
| Bracket skew | Skew or twist of the upper bracket and the base bracket against horizontal must not exceed 0.5° | Public technical literature |
| Foundation | The foundation or floor carrying the tank must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is a good choice | Public technical literature |
| Levelling | After mounting, rock the top plate of the module by hand; if it moves, the module is not level — shim with steel plate until it no longer moves | Company installation instructions |
| Bolting | Tighten all bolts diagonally: pre-tighten first, then torque to specification | Company installation instructions |
| Welding | No current may pass through the weighing module during welding; no other current, such as welding current, may pass through the load cell | Company installation instructions |
| Cable | Do not pull the cable tight, or the tension affects the electrical properties; protect the cable from cuts and abrasion | Company installation instructions |
| Handling | Never lift the module by its cable; avoid knocks and do not let it fall from height | Company installation instructions |
| Piping | All pipes connected to the tank should run horizontally so they do not hang the tank; use flexible connections and put the first pipe support as far from the vessel as possible | Public technical literature |
| Earthing | Each module needs its own independent earth | Public technical literature |
| Wiring and pre-power check | Connect the load cell cable to the junction box as the wiring diagram requires; re-check the wiring for errors and check that the supply voltage is normal | Company installation instructions |
| Calibration conditions | At the vessel design stage allow positions for test weights during calibration and jacking points for installation and service; calibration is required after installation | Public technical literature |
The table lists general requirements from public installation material, applicable to this class of module; the site method and final acceptance rest on the shipping documentation and the actual duty. Indicator-side calibration steps are in the FAQ.
Where do the facts come from?
- Company product documentation (HY-FW parameters and main features): model, category, capacity steps, material and surface finish, the accuracy wording, structural features, the 4-wire connection and colour code, and the application sentence.
- Company specification drawings: mounting arrangements, layout with the three structures, the 4-wire-with-shield wiring schematic, side and end dimension drawings, and the step dimension table.
- Company installation instructions (for dynamic-load modules): system composition and module count, foundation and stiffness requirements, installation tolerances, the prohibitions on mixing capacities and on welding current, handling and cable protection, wiring and pre-power checks.
- Public technical literature (“Selection and installation of weighing modules” and similar; marked at each paragraph): module construction and the three structures, module count and support layout, bracket skew and foundation requirements, piping and calibration requirements, the static-versus-dynamic criterion, and the 70% sizing basis.
Parameter values are transcribed from company documentation and are not a commitment for a specific project; specifications are fixed against the actual duty. Dates and wording on this page follow the header and the footer.
Still unsure which step fits?
Tell us these in one go and we can suggest capacity and module count directly: tank dead weight, product weight, number and layout of support feet, product name and characteristics, site conditions, and whether it is a new build or a retrofit.
- All models, grouped by capacity →
- Sizing formula, worked examples and installation checks →
- Fixed, semi-floating and full-floating modules: how the three divide the work →
- FAQ: numbers wrong or drifting after installation →
HY-FWC-M and HY-FW-M belong to the same series. The documentation collected for this page covers HY-FW only; HY-FWC-M and HY-FW-M were not collected, so their parameters are not described here. Order by the full model suffix and use the shipping documentation of the unit.