How does it differ from HY-1022?
Short answer: in one thing only — cable length. The documented features, the 4-wire colour code, the 7 capacity steps and all 19 parameters are item-for-item identical, and the dimension drawing is the same sheet (same 130, same A values 25.4 / 30).
| Item | HY-SSP1022 (this page) | HY-1022 |
|---|---|---|
| Capacity | 3 to 30 kg, 7 steps | 3 to 30 kg, 7 steps, identical text |
| Features | 5 lines | 5 lines, identical |
| Wiring | 4-wire | 4-wire, same |
| 19 parameters | Item-for-item same | Item-for-item same |
| Dimension drawing | Same sheet (130 / A table 25.4, 30) | Same sheet |
| Cable | 2 m | 1 m |
⚠️ That means one practical thing: the two are mechanically and electrically interchangeable; the only real difference is the length of cable supplied. The documentation does not say why two model numbers exist (a common reason is one short-cable and one long-cable variant for different indicator distances), and this page does not invent a reason. Selection comes down to one question: is 1 m enough to reach the indicator? If not, take this 2 m version and avoid making an extension joint.
How is it wired?
Short answer: 4-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.
| Colour | Terminal | Function |
|---|---|---|
| Red | +input | + excitation |
| Black | −input | − excitation |
| Green | +output | + signal |
| White | −output | − signal |
| pale-yellow | Shield | Shield (drawing only) |
Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-1022, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.2 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤10 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 400±10 |
| Output resistance | Ω | 350±4 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 2 |
What are the dimensions?
Short answer: the drawing gives callouts plus a capacity-grouped A table — the same sheet as HY-1022. Units are not marked and none are added here.
| Capacity / kg | A |
|---|---|
| 3, 5, 7 | 25.4 |
| 10, 15, 20, 30 | 30 |
| View | Values shown |
|---|---|
| Side | 22, 130 |
| Top | A, 15, 108, 12; mounting holes 4-Φ |
The drawing also marks the position of the waterproof sealant (yellow areas) — process indication only, no value given. The A value differs by 4.6 between the 3/5/7 kg steps and 10 kg and up; do not mix them when laying out holes.
What does it look like?
Short answer: three images are supplied — one product photograph, one dimension drawing and one wiring diagram. All three are used here.
⚠️ These three images are the same drawings and the same product as on the HY-1022 page — the documentation covers both model numbers with one image set.
Where does it fit, and where does it not?
Short answer: the documented applications are bench scales, packing scales and process weighing, 3 to 30 kg. The duty is identical to HY-1022; only the cable differs.
- Fits: small bench platforms, small packing scales (bags, bottles), fine dosing in process weighing.
- Why 2 m rather than 1 m: the indicator sits further away, or you do not want to make an extension joint. Shorter is simpler — if 1 m reaches, take HY-1022.
- Capacity limit: 3 to 30 kg. Above that, step up to HY-1241 (30 to 250 kg).
- Not covered: medium and large platforms (HY-1241 / HY-SSP-IL); vessel batching (column modules); high-capacity platforms (HY-SBD).
How can I tell whether the cell has failed?
Short answer: input across red/black 400±10 Ω, output across green/white 350±4 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 400±10 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±4 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The tolerances here are ±10 / ±4 Ω (wider than the ±4 / ±1 of the column type) — judge against this range.
Where do the facts come from?
- Company product documentation: five features, 4-wire colour code, 7 capacity steps, 19 technical parameters.
- Company images (three): one product photograph, a dimension drawing with the capacity-grouped A table, and a wiring diagram.
- Item-by-item check against HY-1022: both pages and all three images (parameters and drawings identical; cable length differs).
- Public technical literature: corner compensation in single-point cells, the effect of cable length on excitation drop.
Values are transcribed from company documentation and are not a commitment for a specific project.