What is it, and how does it differ from HY-1241?
Short answer: both are single-point cells, and the documented electrical parameters are practically identical (sensitivity, zero, temperature range, input and output resistance). The real differences are three: capacity, cable length, and how the protection rating is stated.
| Item | HY-1022 (this page) | HY-1241 |
|---|---|---|
| Capacity | 3 to 30 kg (7 steps) | 30 to 250 kg (5 steps) |
| Sensitivity | 2±0.2 mV/V | 2±0.2 mV/V |
| Zero output | ≤10 %R.C. | ≤10 %R.C. |
| Operating range | -20 to +65 °C | -20 to +65 °C |
| Input / output resistance | 400±10 Ω / 350±4 Ω | 400±10 Ω / 350±4 Ω |
| Cable | 1 m | 2 m |
| Protection | IP67 (consistent in both places) | IP65 / IP67 (that page explains the conflict) |
The two share the same electrical parameter set, so selection is a matter of capacity: 3 to 30 kg for small platforms, 30 to 250 kg for medium ones. The 1 m cable is the shortest in the range — if the indicator is further away, extend it and take care of the shield and joints.
How is it wired?
Short answer: 4-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.
| Colour | Terminal | Function |
|---|---|---|
| Red | +input | + excitation |
| Black | −input | − excitation |
| Green | +output | + signal |
| White | −output | − signal |
| pale-yellow | Shield | Shield (drawing only) |
Earth the shield at one end only. With only 1 m of cable, any extension brings joints that must stay dry and keep the shield continuous into the junction box.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.2 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤10 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 400±10 |
| Output resistance | Ω | 350±4 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 1 |
What are the dimensions?
Short answer: the drawing gives dimension callouts plus a capacity-grouped A table. Units are not marked and none are added here.
| Capacity / kg | A |
|---|---|
| 3, 5, 7 | 25.4 |
| 10, 15, 20, 30 | 30 |
| View | Values shown |
|---|---|
| Side | 22, 130 |
| Top | A, 15, 108, 12; mounting holes 4-Φ |
The drawing also marks the position of the waterproof sealant (yellow areas) — process indication only, no value given. The A value differs by 4.6 between the 3/5/7 kg steps and the 10 kg-and-up steps; do not mix them when laying out holes.
What does it look like?
Short answer: four images are supplied — two product photographs, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.
⚠️ A note on the source archive: all four images sit in the "product photo" folder on the old site, but two of them are actually drawings (dimension and wiring). This page uses them by what they are, not by which folder they came from.
Where does it fit, and where does it not?
Short answer: the documented applications are bench scales, packing scales and process weighing, at 3 to 30 kg — the smallest capacity in this range.
- Fits: small bench platforms, small packing scales (bags, bottles), fine dosing in process weighing.
- Capacity limit: 3 to 30 kg. Above 30 kg, step up to HY-1241 (30 to 250 kg).
- 1 m cable is the shortest here: a remote indicator means an extension, with dry joints and a continuous shield.
- Not covered: medium and large platforms (HY-1241 / HY-SSP-IL); vessel batching (column modules); high-capacity platforms (HY-SBD).
How can I tell whether the cell has failed?
Short answer: input across red/black 400±10 Ω, output across green/white 350±4 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 400±10 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±4 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The tolerances here are ±10 / ±4 Ω (wider than the ±4 / ±1 of the column type) — judge against this range. If values are normal but the reading is unstable, work through installation, piping, junction box and supply first.
Where do the facts come from?
- Company product documentation: five features, 4-wire colour code, 7 capacity steps, 19 technical parameters.
- Company images (four): two product photographs (one used), a dimension drawing with the capacity-grouped A table, and a wiring diagram.
- Item-by-item check against HY-1241: both pages compared directly (same electrical parameters, different capacity and cable).
- Public technical literature: corner compensation in single-point cells, extension requirements for short cables.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: platform size and construction, maximum load and the resolution you need, one cell or several, distance to the indicator, whether there is washdown, and whether loads arrive with impact.