HY-1022 Load Cell: Single Point, Small Capacity, 3 kg to 30 kg, 4-Wire

HY-1022 is a small-capacity single-point load cell, 3 kg to 30 kg in 7 steps, for bench scales, packing scales and process weighing. Laser-welded seal, IP67, corner errors factory-compensated, and a 1 m cable.

Not sure between this step and the next:

+86 183 5123 8137

Short answer: HY-1022 covers 3, 5, 7, 10, 15, 20 and 30 kg in 7 steps; single point, laser-welded, IP67, corner errors compensated; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity 2±0.2 mV/V, input 400±10 Ω, output 350±4 Ω, safe overload 150%, ultimate 300%, cable 1 m.

What is it, and how does it differ from HY-1241?

Short answer: both are single-point cells, and the documented electrical parameters are practically identical (sensitivity, zero, temperature range, input and output resistance). The real differences are three: capacity, cable length, and how the protection rating is stated.

Item-by-item check against HY-1241 (both pages of documentation)
Item HY-1022 (this page) HY-1241
Capacity 3 to 30 kg (7 steps) 30 to 250 kg (5 steps)
Sensitivity 2±0.2 mV/V 2±0.2 mV/V
Zero output ≤10 %R.C. ≤10 %R.C.
Operating range -20 to +65 °C -20 to +65 °C
Input / output resistance 400±10 Ω / 350±4 Ω 400±10 Ω / 350±4 Ω
Cable 1 m 2 m
Protection IP67 (consistent in both places) IP65 / IP67 (that page explains the conflict)

The two share the same electrical parameter set, so selection is a matter of capacity: 3 to 30 kg for small platforms, 30 to 250 kg for medium ones. The 1 m cable is the shortest in the range — if the indicator is further away, extend it and take care of the shield and joints.

How is it wired?

Short answer: 4-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.

4-wire colour code (text and drawing agree)
Colour Terminal Function
Red+input+ excitation
Black−input− excitation
Green+output+ signal
White−output− signal
pale-yellowShieldShield (drawing only)

Earth the shield at one end only. With only 1 m of cable, any extension brings joints that must stay dry and keep the shield continuous into the junction box.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below.

HY-1022 specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.2
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤10
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +65
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ400±10
Output resistanceΩ350±4
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm1

What are the dimensions?

Short answer: the drawing gives dimension callouts plus a capacity-grouped A table. Units are not marked and none are added here.

Dimension A by capacity (from the drawing)
Capacity / kg A
3, 5, 725.4
10, 15, 20, 3030
Other callouts (from the drawing)
View Values shown
Side22, 130
TopA, 15, 108, 12; mounting holes 4-Φ

The drawing also marks the position of the waterproof sealant (yellow areas) — process indication only, no value given. The A value differs by 4.6 between the 3/5/7 kg steps and the 10 kg-and-up steps; do not mix them when laying out holes.

What does it look like?

Short answer: four images are supplied — two product photographs, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.

HY-1022 single-point load cell: natural alloy-steel bar body with relief cut-outs, mounting holes at both ends, cable leaving one end; factory watermark across the image
Product photograph (carries a factory watermark; not retouched). Company documentation.
HY-1022 dimension drawing: side view 22/130, top view A/15/108/12, mounting holes 4-Φ, sealant position, and a capacity-grouped A table (25.4 for 3-7 kg, 30 for 10-30 kg)
Dimension drawing (with the capacity-grouped A table). Company documentation.
HY-1022 wiring diagram: Green excitation+, White signal+, Black excitation-, Red signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

⚠️ A note on the source archive: all four images sit in the "product photo" folder on the old site, but two of them are actually drawings (dimension and wiring). This page uses them by what they are, not by which folder they came from.

Where does it fit, and where does it not?

Short answer: the documented applications are bench scales, packing scales and process weighing, at 3 to 30 kg — the smallest capacity in this range.

How can I tell whether the cell has failed?

Short answer: input across red/black 400±10 Ω, output across green/white 350±4 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 400±10 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±4 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

The tolerances here are ±10 / ±4 Ω (wider than the ±4 / ±1 of the column type) — judge against this range. If values are normal but the reading is unstable, work through installation, piping, junction box and supply first.

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.