First published · Chinese version: HY-SSP1241 称重传感器

You are here: Home > Products > HY-SSP1241

HY-SSP1241 Load Cell: Single Point, 6-Wire with Sense, 30 kg to 250 kg, IP67

HY-SSP1241 is a single-point load cell, 30 kg to 250 kg in 5 steps, for bench scales, packing scales and process weighing. Laser-welded seal, IP67, corner errors factory-compensated, 6-wire with a sense pair, 2 m cable.

⚠️ Replacing an existing HY-1241? Read the wiring section first: the wire count and the meaning of the colours differ.

+86 183 5123 8137

Short answer: HY-SSP1241 covers 30, 50, 100, 200 and 250 kg in 5 steps; single point, laser-welded, IP67, corners compensated; wiring is 6-wire (green = +excitation, black = −excitation, red = +signal, white = −signal, blue = +sense, yellow = −sense); sensitivity 2±0.2 mV/V, input 400±10 Ω, output 350±4 Ω, safe overload 150%, ultimate 300%, cable 2 m.

How does it differ from HY-1241?

Short answer: in four ways, none of them minor. ① wire count (6 vs 4); ② red and green mean the opposite; ③ overall length (150 vs 174); ④ how the protection rating is stated (this page says IP67 in both places; HY-1241 says IP65 in its feature line and IP67 in its table).

HY-SSP1241 vs HY-1241 (both pages of documentation plus both drawings)
Item HY-SSP1241 (this page) HY-1241
Wiring 6-wire with sense 4-wire without sense
Red / green red = +signal, green = +excitation red = +excitation, green = +signal
Capacity 30 to 250 kg, 5 steps 30 to 250 kg, 5 steps (same)
19 parameters Item-for-item same Item-for-item same
Protection IP67 (consistent) IP65 (features) / IP67 (table) — explained on that page
Overall length 150 174
Cable 2 m 2 m (same)

⚠️ The second row matters most: red and green are swapped between the two. Wiring this cell by HY-1241 habit (red as excitation) puts excitation onto the signal pair and signal onto the excitation pair — at best no reading or a reversed one, at worst damage. Re-check the colour order from this page whenever you change model; never carry an old harness over.

How is it wired, and why are red and green reversed?

Short answer: 6-wire, and the text agrees with the drawing wire for wire. The colour assignment really is different from HY-1241 — that is what each model's documentation specifies, not a typo, and this page transcribes it as written. The wire in hand and the shipping diagram govern.

6-wire colour code (text and drawing agree)
Colour Function Terminal name
Green+ excitationExcitation(+)
Black− excitationExcitation(−)
Red+ signalSignal(+)
White− signalSignal(−)
Blue+ senseSense(+)
Yellow− senseSense(−)
pale-yellowshieldShield
Same colour, different job (this model vs HY-1241)
Colour HY-SSP1241 HY-1241
Red+ signal+ excitation
Green+ excitation+ signal
Black− excitation− excitation
White− signal− signal

⚠️ The right way to change model: ① wire by terminal name (Excitation / Signal / Sense), not by colour; ② cells sharing one indicator should share the same wire count and colour order; ③ earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, identical to HY-1241, transcribed below.

HY-SSP1241 specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.2
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤10
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +65
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ400±10
Output resistanceΩ350±4
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm2

What are the dimensions?

Short answer: one set of callouts with overall length 150 (HY-1241 is 174, so the same base plate will not fit). Units are not marked and none are added here.

Dimension callouts (from the drawing)
View Values shown
SideOverall 150, height 38
TopWidth 20.4, 5.2, 25.4 (repeated), 39.8; holes 4-Φ8.5

⚠️ Against the HY-1241 drawing: that one is overall 174, height 65, width 60, hole spacing 122/19/19/7; this one is overall 150, height 38, width 20.4. The numbers are far apart — the two cannot share a base plate hole pattern.

What does it look like?

Short answer: four images are supplied — one product photograph, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.

HY-SSP1241 single-point load cell: natural metal bar body, relief cut-out in the centre, mounting holes at both ends, cable leaving one end; factory watermark
Product photograph (carries a factory watermark; not retouched). Company documentation.
HY-SSP1241 dimension drawing: side overall 150, height 38; top 20.4/5.2/25.4/39.8, holes 4-Φ8.5, sealant and relief cut-out
Dimension drawing (overall 150). Company documentation.
HY-SSP1241 wiring diagram: Green excitation+, Blue sense+, Red signal+, Black excitation-, yellow sense-, white signal-, pale-yellow shield
Wiring diagram (6-wire plus shield). Company documentation.

⚠️ Archive note: these images sit in the "product photo" folder on the old site, but two are actually drawings. This page uses them by what they are.

Where does it fit, and where does it not?

Short answer: the documented applications are bench scales, packing scales and process weighing, 30 to 250 kg. The duty is the same as HY-1241; what differs is the wiring and the outline.

How can I tell whether the cell has failed?

Short answer: input across green/black 400±10 Ω, output across red/white 350±4 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure green / black Around 400±10 Ω; open circuit means a broken internal wire
2 Measure red / white Around 350±4 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

⚠️ Note which pairs are measured here: green/black for excitation and red/white for signal — the reverse of HY-1241 (where red/black is excitation and green/white is signal). Probing the wrong pair gives numbers that mislead.

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: whether the indicator is 4-wire or 6-wire, platform size and construction, load per cell and cell count, the existing base-plate hole pattern (this model differs from HY-1241), and whether there is washdown.

Call +86 183 5123 8137