What is it, and what does "self-stabilising" mean here?
Short answer: the company documentation lists "self-stabilising structure" among its features — meaning the cell keeps the load direction stable without a separate external guide arrangement. The documentation does not describe how that structure is built, and this page does not invent an explanation.
It also lists "low mounting height". Together, those two point at duties where space is tight and the load must stay stable — the documented examples are ground-level platforms and building-material batching.
| # | Feature |
|---|---|
| 1 | Low mounting height |
| 2 | High overall accuracy |
| 3 | Self-stabilising structure |
| 4 | Good long-term stability |
| 5 | Alloy steel, nickel-plated |
| 6 | IP67 |
| 7 | For ground-level platforms and building-material batching control |
The platform type in item 7 is the equipment the cell goes onto, as written in the documentation — not a claim that this factory builds complete platforms.
How is it wired?
Short answer: 6 wires. The product page text, the label on the unit, and the wiring diagram all agree.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| pale-yellow (thick) | shield | Shield |
⚠️ On the shield: the label on the unit says "yellow (thick)" while the drawing says pale-yellow — two ways of writing the same thing (pale yellow / thick yellow). Both are transcribed; the actual wire governs on site. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 3 |
⚠️ The upper operating limit here is +60 °C (not the +65 °C common to most siblings), lower limit -20 °C.
What are the dimensions?
Short answer: the drawing carries dimension callouts plus a hole-spacing table grouped by capacity. Units are not marked and none are added here.
| Capacity | L8 |
|---|---|
| 0.5 t / 1 t / 2 t | 18 |
| 3 t | 16 |
| View | Values shown |
|---|---|
| Side | 40, 14, 30, 80, 92 |
| Top | 50, 18.1, 45.7; thread M8 |
The 3 t step uses L8 = 16, not the 18 of the 0.5–2 t steps — do not mix them when drilling.
What does it look like?
Short answer: four images are supplied — two product photographs, one dimension drawing, and one wiring diagram. This page uses one photograph and both drawings.
All three images come from the company documentation, used as supplied and not retouched. No additional angle photographs are published for this model.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and building-material batching control. The operative word is batching — dosing to a recipe, not just weighing.
- Fits: ground-level platforms; building-material lines (aggregate, cement, sand); duties where mounting space is tight and the load must stay stable.
- Capacity limit: 0.5 to 3 t per cell. Above that, see HY-SBD (15 to 50 t).
- Temperature limit: -20 to +60 °C — 5 °C lower at the top than most siblings. Check hot duties separately.
- Not covered: small bench platforms (single point fits); vessel batching (column modules); higher capacities (double shear beam).
How can I tell whether the cell has failed?
Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The label on the body is a wiring instruction, not a parameter plate — judge with the resistance values above. If the values are normal but the reading is unstable, work through installation, piping, junction box and supply first.
Where do the facts come from?
- Company product documentation: seven features, 6-wire colour code, 4 capacity steps, 19 technical parameters.
- Company images (four): two product photographs (one used), a dimension drawing with the capacity-grouped L8 table, and a wiring diagram.
- Positioning against other structures: the single-point, column and double-shear-beam product pages.
- Public technical literature: stability and mounting stiffness requirements for batching, meaning of IP ratings.
Values are transcribed from company documentation and are not a commitment for a specific project.