First published · Chinese version: HY-SB-M 称重传感器

You are here: Home > Products > HY-SB-M

HY-SB-M Load Cell: 0.5 t to 20 t in 9 Steps, 6-Wire, Self-Stabilising, IP67

HY-SB-M has the widest span in this range — 0.5 t up to 20 t in 9 steps, so a single model covers everything from a batching scale to vehicle and rail weighing. Low profile, self-stabilising, alloy steel nickel-plated, IP67, 6-wire with a sense pair, 4 m cable.

Not sure about the step:

+86 183 5123 8137

Short answer: HY-SB-M covers 0.5, 1, 2, 3, 5, 8, 10, 15 and 20 t in 9 steps; low profile, self-stabilising, alloy steel nickel-plated, IP67; wiring is 6-wire (green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense); sensitivity 2±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, operating range -20 to +60 °C, safe overload 150%, ultimate 300%, cable 4 m.

Why does one model cover a whole range?

Short answer: 9 steps, a 40× spread. From 0.5 t to 20 t, one product serves batching scales (0.5–3 t), medium platforms (5–10 t) and vehicle/rail weighing (15–20 t).

9 steps and their typical duty (by capacity band)
Band Steps Typical equipment
Small 0.5, 1, 2, 3 t batching scales, platform scales, small hoppers
Medium 5, 8, 10 t medium platforms, vessel batching
Large 15, 20 t vehicle weighing, rail weighing

⚠️ Note: the documentation lists "ground-level platforms, vehicle weighing, rail weighing and all kinds of batching" in one applications line. Those are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How does it split from the other low-profile models here?

Short answer: its capacity range overlaps HY-SBS-M, HY-SBT and HY-SBC-M, but only this model reaches 20 t. Selection starts with the capacity band, then the wire count and protection.

Low-profile self-stabilising models here: capacity, wiring, protection
Model Capacity Wiring Protection
HY-SB-M (this page) 0.5–20 t (9 steps) 6-wire IP67
HY-SBS-M 0.5–3 t (4 steps) 6-wire IP67
HY-SBT 0.5–2 t (3 steps) 4-wire IP67
HY-SBC-M 0.5–3 t (4 steps) 4-wire IP67
HY-SBH-M 0.5–3 t (4 steps) 4-wire IP68 / IP67 (documented two ways)

⚠️ Three rules: ① above 5 t only this model covers it (the others stop at 3 t or 2 t); ② need a sense pair — this and HY-SBS-M are 6-wire; ③ need higher protection — see HY-SSH (stainless IP68) or confirm HY-SBH-M's rating first. This model's cable is 4 m, longer than HY-SBC-M (3.1 m) and HY-SBS-M (3 m).

How is it wired?

Short answer: 6-wire. The text and the label on the unit agree.

6-wire colour code (text and unit label agree)
Colour Function Terminal name
Green+ excitationExcitation(+)
Black− excitationExcitation(−)
White+ signalSignal(+)
Red− signalSignal(−)
Yellow+ senseSense(+)
Blue− senseSense(−)
long yellowshieldShield

⚠️ Here it is green = excitation+, white = signal+, red = signal−. That is not the same as the 4-wire HY-1241 on this site (red = excitation+, green = signal+), so never carry a colour order across models. The label writes the shield as "long yellow", the drawing as pale-yellow — same thing. Earth it at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below.

HY-SB-M specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm4

What are the dimensions?

Short answer: no values are copied here. The drawing carries a capacity-grouped table (5 rows covering the 9 steps), but the type is only a few pixels high — at 10× enlargement the strokes still merge and the digits cannot be read. Only the table's existence is recorded.

What the documentation actually contains
Item Situation
Dimension sheets1
Capacity tableyes, 5 rows (several steps share one row)
Values legible?no (still merged at 10×)

⚠️ Why not copy: a dimension drawing exists to be drilled from, and one misread number becomes a scrapped base plate — worse than "no dimension yet". The field is left empty. Ask us for the drawing of this model and state the exact capacity — the 9 steps fall into 5 groups, so say whether you need 0.5/1/2/3 t, 5 t, 8 t, 10 t or 15/20 t.

What does it look like?

Short answer: six images are supplied — product photographs with a wiring label, and one dimension drawing with the capacity table. Two are used here.

HY-SB-M load cell: natural alloy-steel bar body with mounting holes, a wiring label on the side (green +excitation, black -excitation, white +signal, red -signal, yellow +sense, blue -sense, long yellow shield); factory watermark
The label spells out the six wires plus shield. Company documentation.
HY-SB-M dimension drawing: side and top views with callouts, plus a capacity-grouped 5-row table covering 0.5 to 20 t whose values are too small to read
Dimension drawing (capacity table not copied — values illegible). Company documentation.

⚠️ In this drawing's table one row covers several capacity steps (5 rows for 9 steps), so state the exact capacity when asking for it.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms, vehicle weighing, rail weighing and all kinds of batching, 0.5 to 20 t. This is the broadest applications line in the range.

The equipment types named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure green / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure white / red Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

On a parallel bank (especially vehicle or rail platforms), disconnect the other cells at the junction box before measuring one, or you read the parallel value.

Where do the facts come from?

Dimensions are omitted because the table values are illegible.

Still unsure which step fits?

Tell us: load per cell and cell count, platform size and construction, indicator model (6-wire?), whether immersion protection is needed, and mounting space and hole pattern.

Call +86 183 5123 8137