Why does one model cover a whole range?
Short answer: 9 steps, a 40× spread. From 0.5 t to 20 t, one product serves batching scales (0.5–3 t), medium platforms (5–10 t) and vehicle/rail weighing (15–20 t).
| Band | Steps | Typical equipment |
|---|---|---|
| Small | 0.5, 1, 2, 3 t | batching scales, platform scales, small hoppers |
| Medium | 5, 8, 10 t | medium platforms, vessel batching |
| Large | 15, 20 t | vehicle weighing, rail weighing |
⚠️ Note: the documentation lists "ground-level platforms, vehicle weighing, rail weighing and all kinds of batching" in one applications line. Those are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
How does it split from the other low-profile models here?
Short answer: its capacity range overlaps HY-SBS-M, HY-SBT and HY-SBC-M, but only this model reaches 20 t. Selection starts with the capacity band, then the wire count and protection.
| Model | Capacity | Wiring | Protection |
|---|---|---|---|
| HY-SB-M (this page) | 0.5–20 t (9 steps) | 6-wire | IP67 |
| HY-SBS-M | 0.5–3 t (4 steps) | 6-wire | IP67 |
| HY-SBT | 0.5–2 t (3 steps) | 4-wire | IP67 |
| HY-SBC-M | 0.5–3 t (4 steps) | 4-wire | IP67 |
| HY-SBH-M | 0.5–3 t (4 steps) | 4-wire | IP68 / IP67 (documented two ways) |
⚠️ Three rules: ① above 5 t only this model covers it (the others stop at 3 t or 2 t); ② need a sense pair — this and HY-SBS-M are 6-wire; ③ need higher protection — see HY-SSH (stainless IP68) or confirm HY-SBH-M's rating first. This model's cable is 4 m, longer than HY-SBC-M (3.1 m) and HY-SBS-M (3 m).
How is it wired?
Short answer: 6-wire. The text and the label on the unit agree.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| long yellow | shield | Shield |
⚠️ Here it is green = excitation+, white = signal+, red = signal−. That is not the same as the 4-wire HY-1241 on this site (red = excitation+, green = signal+), so never carry a colour order across models. The label writes the shield as "long yellow", the drawing as pale-yellow — same thing. Earth it at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 4 |
What are the dimensions?
Short answer: no values are copied here. The drawing carries a capacity-grouped table (5 rows covering the 9 steps), but the type is only a few pixels high — at 10× enlargement the strokes still merge and the digits cannot be read. Only the table's existence is recorded.
| Item | Situation |
|---|---|
| Dimension sheets | 1 |
| Capacity table | yes, 5 rows (several steps share one row) |
| Values legible? | no (still merged at 10×) |
⚠️ Why not copy: a dimension drawing exists to be drilled from, and one misread number becomes a scrapped base plate — worse than "no dimension yet". The field is left empty. Ask us for the drawing of this model and state the exact capacity — the 9 steps fall into 5 groups, so say whether you need 0.5/1/2/3 t, 5 t, 8 t, 10 t or 15/20 t.
What does it look like?
Short answer: six images are supplied — product photographs with a wiring label, and one dimension drawing with the capacity table. Two are used here.
⚠️ In this drawing's table one row covers several capacity steps (5 rows for 9 steps), so state the exact capacity when asking for it.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms, vehicle weighing, rail weighing and all kinds of batching, 0.5 to 20 t. This is the broadest applications line in the range.
The equipment types named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: batching scales (0.5–3 t), medium platforms (5–10 t), vehicle and rail weighing (15–20 t); 6-wire systems needing a sense pair.
- Why a wide ladder helps: one model covers the whole span, so spares can be standardised instead of stocking a different part per capacity.
- ⚠️ Three limits: ① no usable dimension drawing (table illegible, must be requested); ② IP67 — for IP68 see HY-SSH; ③ -20 to +60 °C — for cold sites see HY-SBC-M (-40 °C).
- Not covered: IP68 duties (HY-SSH / HY-HLJ-M); cold duty (HY-SBC-M); small bench platforms (single point).
How can I tell whether the cell has failed?
Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
On a parallel bank (especially vehicle or rail platforms), disconnect the other cells at the junction box before measuring one, or you read the parallel value.
Where do the facts come from?
- Company product documentation: seven features, 6-wire colour code, 9 capacity steps, 19 technical parameters.
- Company images (six): product photographs with a wiring label, and a dimension drawing with the 5-row capacity table.
- Capacity / wiring / protection check against siblings: the other product pages.
- Public technical literature: field checks on parallel banks, 4-wire versus 6-wire over long runs.
Dimensions are omitted because the table values are illegible.
Still unsure which step fits?
Tell us: load per cell and cell count, platform size and construction, indicator model (6-wire?), whether immersion protection is needed, and mounting space and hole pattern.