HY-SBC-M Load Cell: 0.5 t to 3 t, 4-Wire, Self-Stabilising, -40 to +65 °C, IP67

HY-SBC-M is a low-profile, self-stabilising load cell, 0.5 t to 3 t in 4 steps, for ground-level platforms and building-material batching. Alloy steel nickel-plated, IP67, 4-wire, 3.1 m cable. Its operating range is -40 to +65 °C — a lower floor than most siblings, which matters in cold sites.

Not sure about the step:

+86 183 5123 8137

Short answer: HY-SBC-M covers 0.5, 1, 2 and 3 t; low profile, self-stabilising, alloy steel nickel-plated, IP67; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity 2±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, operating range -40 to +65 °C, safe overload 150%, ultimate 300%, cable 3.1 m.

Why is -40 °C the selection line for this model?

Short answer: the operating range is -40 to +65 °C. Most siblings start at -20 °C (one at -30 °C); this one pushes the floor to -40 °C, and that is what separates it in selection.

Operating ranges across this range (company documentation)
Model Operating range
HY-SBC-M (this page) -40 to +65 °C
HY-SBD -40 to +65 °C
HY-QS -30 to +70 °C
HY-SBS / HY-SBT / HY-SQB -20 to +60 °C
HY-HLJ-M / HY-0743-M / HY-0745A-M -20 to +60 °C

⚠️ Two directions to check: ① cold sites (cold stores, outdoor winter, unheated workshops) — here -40 °C is a hard requirement and a -20 °C model will not do; ② but the upper limit is only +65 °C, below HY-QS at +70 °C, so hot processes need separate checking. Look at both ends, not just one.

What is it, and how does it differ from HY-SBS-M?

Short answer: the same capacity range (0.5/1/2/3 t), both documented as "self-stabilising", both IP67. What differs is the wiring (4-wire vs 6-wire) and the operating range.

HY-SBC-M vs HY-SBS-M (both pages of documentation)
Item HY-SBC-M (this page) HY-SBS-M
Capacity 0.5 to 3 t, 4 steps 0.5 to 3 t, 4 steps (same)
Wiring 4-wire (no sense) 6-wire with sense
Operating range -40 to +65 °C -20 to +60 °C
Protection IP67 IP67 (same)
Cable 3.1 m 3 m
Shared self-stabilising, alloy steel nickel-plated, 381/350 Ω, 150%/300% same

Selection: cold duty takes this model (-40 °C); sense-wire compensation takes HY-SBS-M (6-wire). They cannot both be had at once — this model has no sense pair, HY-SBS-M only reaches -20 °C.

How is it wired?

Short answer: 4-wire. The text and the label on the unit agree.

4-wire colour code (text and unit label agree)
Colour Terminal Function
RedEXC+ / +input+ excitation
BlackEXC− / −input− excitation
GreenSIG+ / +output+ signal
WhiteSIG− / −output− signal
thick yellowSHIELDshield

⚠️ This is 4 wires plus one shield; the shield is for interference and is not counted in "4-wire". Earth it at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below.

HY-SBC-M specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-40 to +65
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm3.1

What are the dimensions?

Short answer: the drawing carries a 12-column capacity table. It is reproduced below, but some digits are heavy in the original — verify against the drawing before machining. Units are not marked.

Capacity-grouped dimensions (from the drawing, units not marked)
Capacity / t M L2 L3 L5 G D E (overall) M1 D2 K N P
0.5 162212.550.530.255133.425.420.215.42217
1 162212.550.530.456.513325.420.216.422.717
2 162214.750.230.456.513725.420.216.42217
3 162214.750.230.456.513925.420.216.42217

⚠️ Two points: ① the rows are not all the same — E (overall length) climbs from 133.4 to 139, L3 changes from 12.5 to 14.7 at 2 t and above, D from 55 to 56.5 — use the row for your capacity; ② some digits are heavy (e.g. column N on the 1 t row), transcribed as legible and to be verified against the original drawing before machining.

What does it look like?

Short answer: six images are supplied — product photographs, more than one wiring-label view, and one dimension drawing with the capacity table. Two are used here.

HY-SBC-M load cell: natural alloy-steel bar body with mounting holes, a wiring label on the side (EXC+ green, EXC- black, SIG+ white, SIG- red, SHIELD thick yellow); factory watermark
The label spells out the four wires plus shield. Company documentation.
HY-SBC-M dimension drawing: side and top views with callouts, plus a capacity-grouped 12-column table (0.5 t, 1 t, 2 t, 3 t; overall length 133.4 to 139)
Dimension drawing (capacity table reproduced above). Company documentation.

⚠️ The label writes the shield as "SHIELD (Thick Yellow)". Across this factory's documents it has appeared as "thick yellow", "long yellow" and pale-yellow — all the same thing; the actual wire governs.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms and building-material batching, 0.5 to 3 t.

The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: load per cell and cell count, the site's lowest and highest temperatures, indicator model (4-wire or 6-wire), whether immersion protection is needed, and mounting space and hole pattern.

Call +86 183 5123 8137