⚠️ First, something the documentation leaves open: why two sensitivity values?
Short answer: the sensitivity cell carries two values — 2±0.002 and 3.0±0.002 — with no statement of which capacity step gets which. Both are transcribed; this page assigns neither.
| Parameter | Unit | As written |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 / 3.0±0.002 |
⚠️ Practical consequence: cells with different sensitivity share the load in proportion to their sensitivity when paralleled, not equally. Mixing the two on one scale makes calibration harder. Confirm that a batch shares the same sensitivity when ordering, or tell us which value you need. This page will not guess that "the 3 t step must be 3.0" — the documentation does not say. The same two-value pattern also appears on HY-SQB, so it is not unique to this model.
What is it, and how does it relate to HY-SBS-M?
Short answer: the capacity range is the same (0.5/1/2/3 t) and both documents claim a "self-stabilising structure". But the wiring and the protection rating differ — this is not the same data sheet renamed.
| Item | HY-HLJ-M (this page) | HY-SBS-M |
|---|---|---|
| Capacity | 0.5 to 3 t, 4 steps | 0.5 to 3 t, 4 steps (same) |
| Wiring | 4-wire (no sense) | 6-wire with sense |
| Protection | IP68 | IP67 |
| Sensitivity | two values (2 / 3.0) | single 2±0.002 |
| Cable | 5 m | 3 m |
| Shared | both self-stabilising, alloy steel nickel-plated, -20 to +60 °C, 381/350 Ω | same |
⚠️ Two points: ① 4-wire has no sense pair, and at 5 m the excitation drop matters more than on a short cable; ② IP68 is continuous immersion protection, steadier than IP67 on washdown — that is this model's main advantage over HY-SBS-M.
How is it wired?
Short answer: 4-wire. The text and the label on the unit agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | EXC+ / +input | + excitation |
| Black | EXC− / −input | − excitation |
| Green | SIG+ / +output | + signal |
| White | SIG− / −output | − signal |
| thick yellow | SHIELD | shield |
⚠️ This is 4 wires plus one shield: the shield is not counted in "4-wire", it is for interference. Earth it at one end only. At 5 m this is a relatively long 4-wire run, so assess the drop.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below. The sensitivity row carries two values — see the section above.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 / 3.0±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP68 |
| Cable length | m | 5 |
What are the dimensions? ⚠️ The drawing's capacity groups differ from the product page
Short answer: the drawing carries a readable capacity table, but its capacity groups do not match the product page: the page lists 0.5/1/2/3 t, while the table lists "0.25/0.5/1 t, 2 t, 3 t, 5 t" — including 0.25 t and 5 t, which the page does not. The table is reproduced as drawn, and the discrepancy is stated.
| Capacity / kg | A | B | D | E | F | G | H | K | M | N | P | Q | S | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.25 / 0.5 / 1 t | 133.4 | 16.2 | 25.4 | 16.4 | 30.7 | 30 | 57.9 | 17 | 4.8 | 12.7 | 22 | 15.9 | 3.1 | 7.7 |
| 2 t | 138.7 | 16.2 | 25.4 | 16.7 | 30.8 | 35.8 | 57.9 | 23 | 9.5 | 12.7 | 22 | 15.9 | 3.1 | 11.7 |
| 3 t | 139.7 | 19.2 | 25.4 | 16.7 | 39 | 35.6 | 57.9 | 23 | 9.5 | 16 | 22 | 15.9 | — | — |
| 5 t | 171.5 | 95.2 | 38.1 | 16.7 | 42.9 | 43 | 73.8 | 29.4 | 11 | 19 | 34.9 | 22.2 | 3.1 | 11.7 |
⚠️ Three things to be clear about: ① the drawing has 0.25 t and 5 t groups that the product page does not list — an inconsistency, transcribed as-is with nothing added or removed; ask us if you need those steps; ② the Q and S cells of the 3 t row are blank on the drawing, not omissions here; ③ some digits are heavy in the original (e.g. column B on the 3 t row), so values are transcribed as legible — verify against the original drawing before machining. Column A (overall length) runs 133.4 to 171.5, a wide spread; use the row for your capacity.
What does it look like?
Short answer: five images are supplied — product photographs with a wiring label, and one dimension drawing with the capacity table. Two are used here.
⚠️ The label writes the shield as "SHIELD (Thick Yellow)". Across this factory's documents the shield has been written as "thick yellow", "long yellow" and pale-yellow — all the same thing; the actual wire governs.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and batching in chemical, food and pharmaceutical plants, 0.5 to 3 t.
The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: medium-to-small batching; chemical, food and pharmaceutical dosing; washdown sites needing IP68.
- Why IP68: batching areas are washed down; IP67 only covers brief immersion.
- ⚠️ Three things to confirm: ① two sensitivity values — keep a batch consistent; ② 4-wire without sense — assess the drop on long runs; ③ the drawing lists 0.25 t and 5 t that the page does not — ask if you need them.
- Not covered: duties needing a sense pair (use the 6-wire HY-SBS-M); high capacities (HY-SBD / HY-QS); small bench platforms (single point).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
Resistance readings cannot tell you whether the sensitivity is 2 or 3.0 — the resistances are identical. Check the nameplate or shipping documentation.
Where do the facts come from?
- Company product documentation: six features, 4-wire colour code, 4 capacity steps, 19 technical parameters (including the two sensitivity values).
- Company images (five): product photographs with a wiring label, and a dimension drawing with the capacity table.
- Check against HY-SBS-M: both pages (same capacity; wiring, protection, sensitivity wording and cable differ).
- Public technical literature: how paralleled cells share load by sensitivity, IP67 versus IP68.
Both inconsistencies — the dual sensitivity value and the drawing's extra capacity groups — are transcribed unchanged.
Still unsure which step fits?
Tell us: load per cell and cell count, indicator model (4-wire or 6-wire), whether a specific sensitivity is required, washdown conditions, and mounting space and hole pattern.