How does it sit against HY-SSP1241? Three steps overlap
Short answer: the two have identical wiring (both 6-wire, same colour order) and identical 19 parameters; what differs is the capacity ladder. And three steps appear on both — 100 kg, 200 kg and 250 kg.
| Step | HY-SSP1260 (this page) | HY-SSP1241 |
|---|---|---|
| 30 / 50 kg | — | yes |
| 100 kg | yes | yes (overlap) |
| 150 kg | yes | — |
| 200 kg | yes | yes (overlap) |
| 250 kg | yes | yes (overlap) |
| 300 kg | yes | — |
| 500 / 635 / 750 kg | yes | — |
⚠️ Choosing within the overlap: at 100 / 200 / 250 kg the two share the same electrical parameters and the same wiring, and the documentation gives no further distinction. In practice the deciding factor is usually the outline and the mounting holes — and this model's dimension drawing has a problem (see the dimensions section). So for the overlapping steps, please call us rather than deciding from a capacity table alone. This page does not invent a reason why one would be better.
How is it wired?
Short answer: 6-wire. The text, the label on the unit and the wiring diagram all agree.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| Red | + signal | Signal(+) |
| White | − signal | Signal(−) |
| Blue | + sense | Sense(+) |
| Yellow | − sense | Sense(−) |
| thick yellow | shield | Shield |
⚠️ The colour order here is identical to HY-SSP1241 (both 6-wire, red = +signal), so swapping between those two needs no wiring change. Against the 4-wire HY-1241, red and green mean the opposite (there red = +excitation) — re-check whenever you cross to a 4-wire model. The label writes the shield as "thick yellow", the drawing as pale-yellow: same thing. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-SSP1241, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.2 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤10 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 400±10 |
| Output resistance | Ω | 350±4 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 2 |
What are the dimensions? ⚠️ The source for this has a problem
Short answer: no dimensions are published here. The drawing supplied alongside this model is titled "MT1260 50kg–750kg" — a different model, not HY-SSP1260. Dimensions from a drawing of a different model are not used on this page.
| Item | Content |
|---|---|
| Drawing title | MT1260 50kg~750kg |
| This model | HY-SSP1260 |
| Dimensions used here | none |
⚠️ Why not: a dimension drawing exists to be drilled from. Numbers lifted from a drawing of a different model may not apply to this one — a base plate drilled to a wrong spacing is scrap, which costs far more than "no dimension yet". So this page leaves the field empty rather than fill it with MT1260 data. Ask us for the drawing of this model (number in the footer).
What does it look like?
Short answer: four images are supplied. Two are used here — a product photograph and a wiring diagram; the dimension drawing is not used because it names a different model.
⚠️ Not used: a further dimension drawing titled "MT1260 50kg~750kg", which names a different model (see the dimensions section). A second photograph from the same angle is also omitted.
Where does it fit, and where does it not?
Short answer: the documented applications are bench scales, packing scales and process weighing, 100 to 750 kg. Eight steps is the finest ladder among the single-point models here, covering medium and larger platforms.
- Fits: medium and large bench platforms, packing scales, process weighing; duties needing 300 to 750 kg per cell (HY-SSP1241 stops at 250 kg).
- Why 8 steps helps: a finer ladder lets you pick a capacity that is just enough, instead of jumping a whole step up.
- ⚠️ Overlapping steps (100/200/250 kg): fully coincident with HY-SSP1241 and electrically identical — the choice turns on outline and holes, and this model's dimension drawing is missing ⇒ please call.
- Not covered: 30–50 kg (use HY-SSP1241); 3–30 kg (HY-SSP1022); large platforms up to 2000 kg (HY-SSP-IL).
How can I tell whether the cell has failed?
Short answer: input across green/black 400±10 Ω, output across red/white 350±4 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 400±10 Ω; open circuit means a broken internal wire |
| 2 | Measure red / white | Around 350±4 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The reference values match HY-SSP1241 (400 / 350), so the test is shared; against the 4-wire HY-1241 the terminal pairs differ (there red/black is excitation).
Where do the facts come from?
- Company product documentation: five features, 6-wire colour code, 8 capacity steps, 19 technical parameters.
- Company images (four): product photographs with a wiring label, and a wiring diagram. The dimension drawing is titled MT1260 and is not used.
- Capacity check against HY-SSP1241: both pages (wiring and parameters identical; capacity steps differ, with three overlapping).
- Public technical literature: corner compensation in single-point cells, why a finer capacity ladder matters.
Dimensions are omitted because the supplied drawing names a different model.
Still unsure which step fits?
Tell us: load per cell, platform size and construction, whether the indicator is 4-wire or 6-wire, mounting space and hole requirements, and whether there is washdown.