What is HY-CW-M, and where does it mount?
Short answer: a weighing module is a structural accessory for a load cell, made of a top plate, a base plate, the load cell, a load-bearing column and support bolts; it combines the load cell, the load-transfer parts and the mounting plate into one unit. (Public technical literature: Selection and Installation of Weighing Modules.)
The module usually mounts on the lower part of the scale body — the feet, the platform and so on — and can also be mounted on the upper part, on the waist of a vessel, tank or hopper. All modules of one weighing system must sit in the same horizontal plane. (Public technical literature: Selection and Installation of Weighing Modules.)
The purpose sentence in the company documentation for this model is: for weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales. That sentence is also why the model is classed as a dynamic-load module. Company product documentation.
The difference from buying a load cell on its own: a module brings the cell, the load-bearing structure and the mounting connection together, so it carries load as soon as it is fitted to a foot, and part of the error caused by poor mounting is absorbed by the structure. A bare cell leaves the load point, the restraint and the mounting face to be solved on site.
Where it sits in a weighing system
A module connects easily to machine parts of any shape — conveyors, platforms, standing tanks, vessels, hoppers — to form a weighing control system. Such a system normally consists of a display and control indicator, a junction box, the weighing modules and cable. Company installation instructions.
Modules of different models and sizes can be selected for the duty. A weighing system normally uses 3 to 6 modules (up to 12) as one group; the foundation carrying the modules must meet the stiffness requirement and must be in one horizontal plane, or be adjustable to it, so that every module carries an even share of the load. Company installation instructions.
How does HY-CW-M differ from HY-CWC and HY-CWC-M, and why can the colour codes not be reused?
Short answer: first check whether the mounting point sees horizontal impact force. Static-load modules are for static weighing where lateral forces are small; dynamic-load modules are for machinery that carries horizontal force, such as production lines and conveyors. Where product is fed vertically into a hopper, tank, vessel or silo by conveyor or pump, a static-load module is the choice; where product is fed horizontally onto the platform or into the vessel, horizontal impact occurs and a dynamic-load module is the choice. (Criterion from public technical literature: Selection and Installation of Weighing Modules.)
On that criterion HY-CW-M and HY-CWC are dynamic-load modules and HY-CWC-M is a static-load module. The three models each have their own material, wiring system and colour definition; the suffix differs by one or two letters, and none of the three can stand in for another.
The three models side by side
| Item | HY-CW-M (this page) | HY-CWC | HY-CWC-M |
|---|---|---|---|
| Module type | Dynamic-load module, carries horizontal impact force | Dynamic-load module | Static-load module |
| Material and finish | Alloy steel, nickel-plated | Stainless steel | Stainless steel, hermetically welded sealed (IP68 protection) |
| Wiring system | 6-wire with shield (one +sense / −sense pair beyond the 4-wire set, plus 1 shield wire) | 4-wire with shield (+excitation / −excitation / +signal / −signal, plus 1 shield wire) | 6-wire (+sense / −sense included) |
| Colour code | Green +excitation; black −excitation; white +signal; red −signal; yellow +sense; blue −sense (6 wires) | Two sets, split by capacity: one for 0.5–3 t and one for 8–20 t, with the excitation and signal colours exactly reversed between them. Red = +excitation is the definition in one of the two sets | Green +excitation; black −excitation; white +signal; red −signal; yellow +sense; blue −sense |
Load-type criteria above come from public technical literature (Selection and Installation of Weighing Modules); material and wiring values come from the company product documentation and product drawings of each model. HY-CWC-M is described in detail on the HY-CWC-M page.
Why the colours and wire order cannot be copied from another model
- One letter in the suffix is a different model: HY-CW-M on this page and HY-CWC-M differ by one C — one is a dynamic-load module, the other a static-load module, and the material differs too; HY-CWC is 4-wire with shield. Quote the full suffix; a series name alone does not say which wiring definition applies. Company product documentation.
- Different wire count means the terminals do not line up: HY-CW-M is 6-wire with shield, one sense pair more than the 4-wire with shield of HY-CWC; a 4-wire system has no sense terminals, so wiring by 6-wire terminal numbers leaves two wires with nowhere to go. Company product documentation.
- The excitation and signal colours are swapped between models: both are dynamic-load modules, yet HY-CW-M here uses green = +excitation while HY-CWC uses red = +excitation. Copying colours across models puts excitation onto a signal terminal. Company product documentation.
- The result of a mistake is "it powers up, the reading is wrong": excitation and signal reversed do not raise an error at once, but the indicator reading no longer matches the load applied. Confirm the full suffix and the shipping documentation before wiring, then follow the diagram on the unit. Practice from public technical literature.
- One source difference exists inside this model: the colour order given in the company installation instructions for HY-CW-0–20 t is not the same set as the company product documentation. It is stated as it stands in the colour-code row of the specification table below; this page does not choose one set for the customer. Company installation instructions.
What are the specifications, and where does each value come from?
Short answer: the table below lists the documented values of HY-CW-M one by one with their source; the right-hand column translates each parameter into what has to be checked at selection and installation. Values are transcribed as given — no conversion, no merging, and no capacity step that the documentation does not list.
| Parameter | Value (with source) | What it determines |
|---|---|---|
| Model | HY-CW-M Company product documentation | The model identifier used for ordering and enquiry. The family also has models whose suffix differs by one or two letters (HY-CWC / HY-CWC-M); their wiring systems and colour definitions are different (see the colour-code row), so quote the full suffix. |
| Category | Weighing module Company product documentation | It is a structural part plus a load cell, so capacity, material and mounting dimensions all have to be checked together; load-cell figures alone are not enough. |
| Capacity steps | 0.5, 1, 2, 3, 5, 8, 10, 15, 20 t Company product documentation (9 steps, as listed) | The maximum load one module takes. Total system capacity = rated capacity × number of modules, so calculate with vessel weight and product weight first, then take the next step up. |
| Material and finish | Alloy steel, nickel-plated Company product documentation | Sets the environment it can be used in. This model is alloy steel with a nickel-plated finish, not the stainless steel of the other family members, so do not judge its service life by the stainless models; the nickel plating is one precondition for resistance to ordinary environmental attack. Company product documentation. |
| Overall accuracy | The company documentation says only that a high-quality load cell is used and that weighing accuracy is high; no numeric value is given Company product documentation | Only a qualitative statement exists, so this page publishes no accuracy figure and makes no conversion. Where a quantitative figure is needed, confirm it against the application and the indicator used. |
| Structural features | Self-aligning load head that keeps the correct loading position and gives good repeatability; adjustable horizontal restraint bolts; an alignment tool that establishes the correct working position; simple, quick installation; easy maintenance that saves downtime Company product documentation | The self-aligning head decides whether the loading position stays correct under eccentric load; the adjustable restraint bolts and the alignment tool decide whether the module can be brought to its correct working position on site. On the job: locate with the alignment tool, then level with the restraint bolts. |
| Wiring system | 6-wire with shield (+excitation / −excitation / +signal / −signal / +sense / −sense, plus 1 shield wire) Company product documentation + company installation instructions | The difference from 4-wire is the +sense / −sense pair: it feeds the excitation voltage drop along the cable back to the indicator. Where the cable is long, or the module sits far from the indicator, this pair goes to the sense terminals of the indicator or junction box. Principle from public technical literature. |
| Colour code | Green +excitation; black −excitation; white +signal; red −signal; yellow +sense; blue −sense (6 wires). The nameplate on the unit also marks: yellow (long) = shield. Company product documentation / company product drawing | The reference for wiring on site. This row follows the company product documentation; the wiring diagram in the product drawing and the nameplate on the unit agree with it. One source difference has to be stated as it stands: the company installation instructions give a different definition for HY-CW-0–20 t — red = excitation+, black = excitation−, green = signal+, white = signal−, yellow = shield, with no +sense / −sense pair. The two are not the same set, and this page does not choose one for the customer. Wire to the shipping documentation and the diagram on the unit; do not copy colours across models or suffixes. |
| Wiring diagram | 6-wire with shield: green = excitation+; yellow = sense+; white = signal+; black = excitation−; blue = sense−; red = signal−; pale yellow = shield Company product drawing (one drawing below) | One more wire than the written table: the drawing shows the shield as a separate wire. The shield suppresses interference from inverters and power cables; on site it is earthed at one end and signal cables are kept away from power cables. How the shield is terminated in a given panel follows the shipping documentation and the diagram on the unit. Practice from public technical literature. |
| Outline dimensions | Four groups by capacity (0.5–3 t / 5–8 t / 10 t / 15–20 t); two dimensioned views (side and end) plus one per-group dimension table, with 16 callouts in total: L, L1, L2, A, A1, B, B1, C, C1, H, H1, H2, T, ΦP, ΦG, D. Values are not re-typed here; the drawing governs. Company product drawing (three drawings below) | Changing the capacity step changes the outline and the mounting hole positions — capacity is not one number that can be swapped on its own. Fix the capacity step before modifying the legs or pouring a foundation, then check the hole spacing and overall height of that group against the space available. Values per the company product drawing. |
| Applications listed in the documentation | For weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales Company product documentation | The documentation names the kind of application; it is not a statement that every such application fits. For a given machine, check vessel weight, product weight, number of feet and site conditions. |
Values and wording are transcribed from company documentation, including the fact that no numeric accuracy value is given. Every explanation added on this page is marked as such and comes from public technical literature, not from a company commitment. The company documentation for this model gives no protection rating and no long-term stability statement, so neither row is set here and no value is inferred.
Which value applies under which conditions?
Short answer: check the load per module against "dead load + live load ≤ rated capacity × number of modules × 70%", then take the next capacity step up; take one module per actual support point. (Criterion from public technical literature.)
dead load + live load ≤ rated capacity × number of modules × 70%
The formula is written out in words so that it can be copied, sent to a work group or printed for a design office. Worked examples are on the Selection & Resources page.
Case by case
| Your case | What to take | Basis |
|---|---|---|
| The vessel already has support feet | Set the module count by the number of support feet: 3 feet, 3 modules; 4 feet, 4 modules | Public technical literature |
| A new vertical cylindrical vessel | Three-point support is the more stable arrangement; where wind, sway or vibration has to be considered, four-point support is preferred | Public technical literature |
| The calculated load per module falls between two steps | Take the next step up, never the next step down | Public technical literature |
| How many to buy per set and how to arrange them | Use one fixed and one semi-floating module in a set and fill the remaining positions with full-floating modules; three-module and four-module sets are the common arrangements | Public technical literature |
| Product is fed horizontally onto the platform or into the vessel | Horizontal impact force occurs, so the criterion points to a dynamic-load module; this model is documented as a dynamic-load module | Criterion from public technical literature (Selection and Installation of Weighing Modules); model type from company product documentation |
| The module sits far from the indicator | Use the sense wires of the 6-wire system to compensate the voltage drop on the long run, terminated as in the colour-code row | Principle from public technical literature |
| Replacing an old module without changing the foundation | Measure the existing hole positions and the height available, then check them against the two dimensioned views and the per-group dimension table on this page | Dimensions from the company product drawing |
Where does it fit, and where does it not?
Short answer: what the company documentation and the sourced content of this page can support is "weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales", plus the case where product is fed horizontally onto the platform or into a vessel and horizontal impact occurs. Items the documentation does not give — protection rating, long-term stability, a numeric accuracy value, material grade and temperature range — are not inferred here and no conclusion is drawn for the customer.
Fits (documented)
- Weighing and process weighing control with horizontal impact force: the purpose sentence in the company documentation is "for weighing and process weighing control in applications with horizontal impact force, such as conveyor-roller scales". Company product documentation.
- Product fed horizontally onto the platform or into a vessel: horizontal impact occurs in these cases and a dynamic-load module is the choice. Criterion from public technical literature (Selection and Installation of Weighing Modules).
- Machinery that carries horizontal force: dynamic-load modules are for this class of equipment, such as production lines and conveyors. Criterion from public technical literature (Selection and Installation of Weighing Modules).
- Replacing the old modules of an existing machine: a module connects easily to machine parts of any shape and suits this kind of retrofit. Company installation instructions.
Boundaries and where it does not fit
- The company documentation gives no protection rating and no long-term stability statement for this model: neither can be inferred here, and no value is published; where either matters, check it separately against the process and the site. Company product documentation does not record them.
- The company documentation gives no numeric accuracy value: the wording is only "a high-quality load cell is used and weighing accuracy is high", so this page gives no accuracy figure and makes no conversion. Company product documentation.
- The company documentation gives no material grade and no temperature range: these cannot be inferred here either. Company product documentation does not record them.
- Modules of different capacities must not be mixed in one weighing system. Company installation instructions.
- Welding current must not pass through the load cell: no current from welding or any other source may cross the module, or the cell is damaged. Company installation instructions.
- The vessel must not be tied mechanically to parts that the modules do not carry, or the reading will be wrong. Public technical literature (Selection and Installation of Weighing Modules).
- Piping left untreated prevents calibration: a rigid pipe takes part of the real load away from the cell; use a flexible hose or make the connecting pipe as long as possible. Public technical literature.
What does it look like, and how are the dimensions marked?
Short answer: below are 1 photograph of the unit and 6 drawings from the company drawing set: mounting arrangements, module layout plan, wiring diagram, two dimensioned views (side and end) and the per-group dimension table. All images are local files; the page loads no external resource.
One photograph and six drawings are company product images used unaltered, with no retouching. Where an image and the written documentation disagree, the written documentation governs.
What has to be right at installation and wiring?
Short answer: three things decide whether a module works — the stiffness and level of the base, the verticality of the connection, and whether external paths such as piping and welding have been taken out of the load chain. Each row below gives a figure or an action that can be checked.
| Item | Requirement | Source |
|---|---|---|
| Verticality | The vertical axis of every module must coincide with the perpendicular to the mounting plate, deviation no more than 1.5°; where a face is uneven or out of vertical, correct it with shims or equivalent | Company installation instructions |
| Frame and base stiffness | The frame and base plate carrying the modules must be stiff enough; the stiffness has to reach 1/1000 | Company installation instructions |
| Bracket skew | The angle to horizontal caused by skew or twist of the upper bracket and of the base bracket must not exceed 0.5° | Public technical literature (Selection and Installation of Weighing Modules) |
| Foundation | The foundation or floor carrying the vessel must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is the better choice for the modules | Public technical literature (Selection and Installation of Weighing Modules) |
| Levelling | After mounting, rock the top plate of the module by hand; if it moves, the module is not level — shim it until it no longer moves | Company installation instructions |
| Fixing method | Two methods are used once level: bolted (top plate bolted to the vessel foot or bracket, base plate bolted to the steel structure or floor) or welded (top plate welded to the vessel foot, base plate welded to the steel structure) | Company installation instructions |
| Bolt tightening | Tighten all bolts diagonally, pre-tighten first, then tighten to the specified torque | Company installation instructions |
| Welding | No current may pass through the weighing module during welding; no other current (welding current, for instance) may cross the load cell, or the cell is damaged | Company installation instructions |
| Cable | Do not pull the cable tight — tension affects the electrical properties; protect the cable from cuts and abrasion | Company installation instructions |
| Handling | Never lift the module by its cable when taking it out of the packaging; avoid knocks and do not let the module fall from a height | Company installation instructions |
| Capacity check | Check the capacity of each module before mounting; modules of different capacities must never be used in one weighing system | Company installation instructions |
| Wiring and re-check | Connect the load cell cable to the junction box as the diagram requires and complete the run from the junction box to the display and control indicator; re-check every terminal and verify the supply voltage. Take the colour order from the colour-code row of this page and do not reuse the colours of HY-CWC / HY-CWC-M | Company installation instructions; colour difference as stated in the specification table above |
| Two modules per direction | Where only two modules take the impact load in one direction, those two modules must sit on the same side of the scale | Company product documentation |
| Piping | Run all pipes connected to the vessel horizontally so that they do not hang the vessel; put the first pipe support as far from the vessel as possible; use a flexible connection where possible | Public technical literature (Selection and Installation of Weighing Modules) |
| Earthing and access | Mount the modules where they can be serviced; each module needs its own independent earth | Public technical literature (Selection and Installation of Weighing Modules) |
| Calibration conditions | Allow for test-weight positions and for jacking points for installation and maintenance at the vessel design stage; calibration has to be done once installation is complete | Public technical literature (Selection and Installation of Weighing Modules) |
The table is the general requirement set of public installation literature and applies to modules of this type; the procedure on site and the final judgement stay with the shipping documentation and the actual conditions. Indicator-side steps are covered in the FAQ.
Where do the facts on this page come from?
- Company product documentation (HY-CW-M data): model, category, capacity steps, material and finish, the qualitative accuracy wording, structural features, 6-wire with shield wiring and colour order, the note on two modules taking impact in one direction, documented applications.
- Company product drawings: mounting arrangements, module layout plan, 6-wire with shield wiring diagram, dimensioned views (side and end) and the per-group dimension table.
- Company installation instructions (HY-CW-M shipping instructions): the second wiring definition and the colour difference, mounting deviation and stiffness requirements, the prohibitions on mixing capacities and on welding current, cable and handling care, wiring and re-check requirements.
- Public technical literature (Selection and Installation of Weighing Modules and related material, marked at each sentence): module construction, static vs dynamic criteria, module count and support arrangement, sizing practice, piping and calibration requirements.
Values in the tables are company documentation values and are not a commitment for a specific project; confirm the specification against the application.
Still unsure which step fits?
Tell us these in one go and we can suggest the capacity and the module count directly: vessel weight, product weight, number and layout of support feet, product name and characteristics, site conditions, and whether it is a new build or a retrofit.