HY-SB Load Cell: 0.5 t to 20 t in 9 Steps, 4-Wire, Self-Stabilising, IP67

HY-SB is a wide-span load cell — 0.5 t to 20 t in 9 steps — for ground-level platforms, vehicle and rail weighing and all kinds of batching. Low profile, self-stabilising, alloy steel nickel-plated, IP67, 4-wire, 4 m cable. Its only difference from HY-SB-M is the wiring (4-wire here, 6-wire there); everything else matches.

Not sure between 4-wire and 6-wire — tell us which indicator you have:

+86 183 5123 8137

Short answer: HY-SB covers 0.5, 1, 2, 3, 5, 8, 10, 15 and 20 t in 9 steps; low profile, self-stabilising, alloy steel nickel-plated, IP67; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity 2±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, operating range -20 to +60 °C, safe overload 150%, ultimate 300%, cable 4 m.

How does it differ from HY-SB-M?

Short answer: in one thing only — the wiring. This one is 4-wire (no sense pair); HY-SB-M is 6-wire (with a sense pair). The two share word-for-word identical features (7 lines), the same 9 capacity steps, item-for-item identical 19 parameters, and the same 4 m cable.

HY-SB vs HY-SB-M (both pages of documentation)
Item HY-SB (this page) HY-SB-M
Wiring 4-wire: red +excitation, black −excitation, green +signal, white −signal 6-wire: adds yellow +sense, blue −sense
Capacity 0.5 to 20 t, 9 steps 0.5 to 20 t, 9 steps (same)
Features 7 lines 7 lines, word-for-word same
19 parameters item-for-item same item-for-item same
Cable 4 m 4 m (same)

⚠️ Choosing 4-wire or 6-wire: ① 4 m cable is enough and the indicator is nearby — 4-wire (this model) is fine, the drop is small; ② the cable must be extended, or your indicator is a 6-wire type — take HY-SB-M and let the indicator compensate through the sense pair; ③ a 4-wire cell can be connected to a 6-wire indicator, but the compensation is then lost. This pair (HY-SB / HY-SB-M) follows the same rule as HY-SBS / HY-SBS-M and HY-MTB / HY-MTB-M: same parameters, wiring is the only difference.

How is it wired?

Short answer: 4-wire. The text and the drawing agree.

4-wire colour code (text and drawing agree)
Colour Terminal Function
RedExcitation(+)+ excitation
BlackExcitation(−)− excitation
GreenSignal(+)+ signal
WhiteSignal(−)− signal
thick blackShieldshield

⚠️ This is 4 wires plus one shield; the shield is not counted in "4-wire". The label on this unit writes the shield as "thick black" — across this factory's documents it also appears as "thick yellow", "long yellow" and pale-yellow, so work from the wire in hand, never copy a colour across models. Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, identical to HY-SB-M.

HY-SB specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm4

What are the dimensions?

Short answer: the drawing carries symbols only, no numbers. It labels parts F, H, L1, L2, L3, L4, L5 and Φ9, Φ21, 2-Φ9 — without the value behind any symbol.

Symbols on the drawing and the parts they mark (no values)
Symbol Part
L1overall length
L2 / L3 / L4 / L5section lengths and hole spacing
F / Hthickness / height
Φ9 / Φ21 / 2-Φ9mounting holes (both) and centre bore

⚠️ Why no numbers: the drawing has symbols but no value table. This page will not estimate — dimensions are used for machining and hole alignment, and an estimated number moves the risk onto the customer. Ask us for the drawing of this model and state the exact capacity (9 steps).

What does it look like?

Short answer: six images are supplied. This page uses one product photograph and two drawings; one further photograph is not used because its nameplate carries a mark unrelated to product parameters.

HY-SB load cell: natural alloy-steel bar body with mounting holes, a wiring label on the side (EXC+ red, EXC- black, SIG+ green, SIG- white, SHIELD thick black); factory watermark
The label spells out the four wires plus shield. Company documentation.
HY-SB wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.
HY-SB dimension drawing: top and side views labelled with F/H/L1-L5/Φ9/Φ21 symbols and no numeric values
Dimension drawing (symbols only, no values). Company documentation.

⚠️ Not used: one further product photograph whose nameplate carries a mark unrelated to product parameters (along with the full model number and serial). It is not used, and the mark is neither described nor referenced here.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms, vehicle and rail weighing and all kinds of batching, 0.5 to 20 t.

The equipment types named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

On a parallel bank (especially vehicle or rail platforms), disconnect the other cells at the junction box before measuring one.

Where do the facts come from?

Dimensions are omitted because the drawing shows symbols without a value table.

Still unsure which step fits?

Tell us: load per cell and cell count, indicator model (4-wire or 6-wire), distance to the indicator, mounting space and hole pattern, and whether the site is washed down.

Call +86 183 5123 8137