How does it differ from HY-SB-M?
Short answer: in one thing only — the wiring. This one is 4-wire (no sense pair); HY-SB-M is 6-wire (with a sense pair). The two share word-for-word identical features (7 lines), the same 9 capacity steps, item-for-item identical 19 parameters, and the same 4 m cable.
| Item | HY-SB (this page) | HY-SB-M |
|---|---|---|
| Wiring | 4-wire: red +excitation, black −excitation, green +signal, white −signal | 6-wire: adds yellow +sense, blue −sense |
| Capacity | 0.5 to 20 t, 9 steps | 0.5 to 20 t, 9 steps (same) |
| Features | 7 lines | 7 lines, word-for-word same |
| 19 parameters | item-for-item same | item-for-item same |
| Cable | 4 m | 4 m (same) |
⚠️ Choosing 4-wire or 6-wire: ① 4 m cable is enough and the indicator is nearby — 4-wire (this model) is fine, the drop is small; ② the cable must be extended, or your indicator is a 6-wire type — take HY-SB-M and let the indicator compensate through the sense pair; ③ a 4-wire cell can be connected to a 6-wire indicator, but the compensation is then lost. This pair (HY-SB / HY-SB-M) follows the same rule as HY-SBS / HY-SBS-M and HY-MTB / HY-MTB-M: same parameters, wiring is the only difference.
How is it wired?
Short answer: 4-wire. The text and the drawing agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | Excitation(+) | + excitation |
| Black | Excitation(−) | − excitation |
| Green | Signal(+) | + signal |
| White | Signal(−) | − signal |
| thick black | Shield | shield |
⚠️ This is 4 wires plus one shield; the shield is not counted in "4-wire". The label on this unit writes the shield as "thick black" — across this factory's documents it also appears as "thick yellow", "long yellow" and pale-yellow, so work from the wire in hand, never copy a colour across models. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-SB-M.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 4 |
What are the dimensions?
Short answer: the drawing carries symbols only, no numbers. It labels parts F, H, L1, L2, L3, L4, L5 and Φ9, Φ21, 2-Φ9 — without the value behind any symbol.
| Symbol | Part |
|---|---|
| L1 | overall length |
| L2 / L3 / L4 / L5 | section lengths and hole spacing |
| F / H | thickness / height |
| Φ9 / Φ21 / 2-Φ9 | mounting holes (both) and centre bore |
⚠️ Why no numbers: the drawing has symbols but no value table. This page will not estimate — dimensions are used for machining and hole alignment, and an estimated number moves the risk onto the customer. Ask us for the drawing of this model and state the exact capacity (9 steps).
What does it look like?
Short answer: six images are supplied. This page uses one product photograph and two drawings; one further photograph is not used because its nameplate carries a mark unrelated to product parameters.
⚠️ Not used: one further product photograph whose nameplate carries a mark unrelated to product parameters (along with the full model number and serial). It is not used, and the mark is neither described nor referenced here.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms, vehicle and rail weighing and all kinds of batching, 0.5 to 20 t.
The equipment types named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: batching scales (0.5–3 t), medium platforms (5–10 t), large platforms (15–20 t); 4-wire indicators; cost-sensitive duties where sense compensation is not needed.
- Why 9 steps: one model covers the whole span, so spares can be standardised.
- ⚠️ Three checks: ① wiring — this is 4-wire, take HY-SB-M if you need the sense pair; ② dimensions must be requested (symbols only); ③ IP67 — for IP68 see another model.
- Not covered: duties needing a sense pair (HY-SB-M); IP68 (HY-HLJ-M / HY-SBH-M / HY-GD-M); cold sites (HY-SBC-M at -40 °C).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
On a parallel bank (especially vehicle or rail platforms), disconnect the other cells at the junction box before measuring one.
Where do the facts come from?
- Company product documentation: seven features, 4-wire colour code, 9 capacity steps, 19 technical parameters.
- Company images (six): product photographs (one used, one skipped for a nameplate mark), wiring diagram, dimension drawing (symbols only).
- Item-by-item check against HY-SB-M: both pages (the only difference is the wiring).
- Public technical literature: 4-wire versus 6-wire over long runs.
Dimensions are omitted because the drawing shows symbols without a value table.
Still unsure which step fits?
Tell us: load per cell and cell count, indicator model (4-wire or 6-wire), distance to the indicator, mounting space and hole pattern, and whether the site is washed down.