Why are its sensitivity and overload the most unusual here?
Short answer: sensitivity 1±0.002 mV/V — the only 1.0 in this range (others are 2.0 or 1.94); safe overload 200% and ultimate 500% — the highest here (most are 150% / 300%). Together those two point at heavy load with impact — and the industries named include steel.
| Model | Sensitivity (mV/V) | Safe / ultimate overload |
|---|---|---|
| HY-PGD-M (this page) | 1±0.002 | 200% / 500% |
| HY-0743-M / HY-0745A-M | 1.94±0.002 | 150% / 300% |
| HY-SB-M / HY-SBD / HY-QS and most others | 2±0.002 | 150% / 300% |
| HY-QS (40-50 t steps) | 2±0.002 | 120% / 200% |
⚠️ What sensitivity 1.0 means in practice: at the same load, this cell's output is half that of a 2.0 model. So ① the indicator needs more resolution / a smaller minimum division (a smaller signal means noise takes a bigger share); ② it cannot be dropped in where a 2.0 cell was — the output differs by a factor of two, so it must be recalibrated and the indicator range checked; ③ do not parallel it with a 2.0 model, or the load splits badly. On the other hand, 200%/500% overload buys impact margin, which steel and heavy batching need more.
How does it split from HY-GD-M?
Short answer: both are column, stainless, IP68, but the capacity band, sensitivity and overload are completely different. HY-GD-M runs 15–100 t at sensitivity 2.0; this one runs 2–50 t at 1.0 with higher overload.
| Item | HY-PGD-M (this page) | HY-GD-M |
|---|---|---|
| Capacity | 2 to 50 t (6 steps) | 15 to 100 t (5 steps) |
| Sensitivity | 1±0.002 | 2±0.002 |
| Overload (safe / ultimate) | 200% / 500% | 150% / 300% |
| Resistance (in / out) | 695±7 / 600±2 | 1160±10 / 1000±3 |
| Protection / material | IP68 / stainless | IP68 / stainless (same) |
| Industries named | chemical, steel, pharmaceutical | vehicle weighing, rail weighing, heavy batching |
⚠️ Selection: ① column type at 2–10 t — only this model; ② 100 t — only HY-GD-M; ③ heavy impact — this model has one step more overload margin; ④ note the sensitivity differs by a factor of two, so indicator and calibration follow the actual model.
How is it wired?
Short answer: 6-wire. The text and the drawing agree wire for wire.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
| pale-yellow | shield | Shield |
⚠️ Here it is green = excitation+, white = signal+, red = signal−, not the 4-wire HY-1241 order (red = excitation+), so never carry a colour order across models. The cable is 13 m — a long run; connect the sense pair, or the 13 m drop goes straight into the reading. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 1±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.01 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -40 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 695±7 |
| Output resistance | Ω | 600±2 |
| Insulation resistance | MΩ | 5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 200 |
| Ultimate overload | %R.C. | 500 |
| Protection | — | IP68 |
| Cable length | m | 13 |
The insulation cell reads "5000" with no "≥" sign in the original; it is transcribed as written.
What are the dimensions?
Short answer: the drawing carries actual numbers (more complete than the sibling column model HY-GD-M, whose drawing has symbols only). Units are unmarked and none are added here.
| Part | Values shown |
|---|---|
| Overall height | 118.6 |
| Body diameter | Φ76 |
| Width | 102 |
| Other | centre bore Φ40; bottom boss height 10; top ball diameter ΦA (shown as a symbol); cable exit 20 |
⚠️ Two notes: ① the top diameter is the symbol ΦA with no number on the drawing — that value is left out here; ② the rest are actual numbers, transcribed. Verify against the original drawing before machining.
What does it look like?
Short answer: four images are supplied — a product photograph, a wiring diagram and a dimension drawing. Three are used here.
Where does it fit, and where does it not?
Short answer: the documented applications are batching in chemical, steel and pharmaceutical plants, 2 to 50 t. The "steel" industry does not appear on any other model's page here.
The industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete plant.
- Fits: steel, chemical and pharmaceutical batching; heavy load with impact (200%/500% overload margin); IP68 sites; limited mounting height.
- Why high overload helps: in steel and mineral duty the drop impact is large; 200% safe and 500% ultimate mean the cell survives the same impact more readily.
- ⚠️ Three checks: ① sensitivity 1.0 (half the output of a 2.0 cell — indicator and calibration must match); ② do not parallel with 2.0 models; ③ top diameter ΦA has no number on the drawing.
- Not covered: 15 t and up to 100 t (HY-GD-M); 2.0 sensitivity (most other models); small capacities (column modules or single point).
How can I tell whether the cell has failed?
Short answer: input across green/black 695±7 Ω, output across white/red 600±2 Ω, insulation to body 5000 MΩ (as written, no "≥").
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 695±7 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 600±2 Ω |
| 3 | Measure insulation to body | 5000 MΩ range; a clear drop means moisture or a damaged seal |
⚠️ Do not borrow HY-GD-M (1160/1000) or HY-SBD (772/700) references — this model is 695/600. Also: normal resistances do not prove the sensitivity is right — at 1.0, fitting a 2.0 spare can leave resistances normal but the output doubled.
Where do the facts come from?
- Company product documentation: six features, 6-wire colour code, 6 capacity steps, 19 technical parameters.
- Company images (four): product photograph, wiring diagram, dimension drawing with actual numbers.
- Sensitivity and overload check against other models: the other product pages.
- Public technical literature: how sensitivity affects indicator resolution, and how overload margin relates to impact loading.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: load per cell and cell count, indicator model (it must suit sensitivity 1.0), impact severity (how material is dropped), mounting form, whether IP68 is needed, and any height limit.