HY-PGD-M Load Cell: Column Type, 2 t to 50 t, Sensitivity 1.0, 200%/500% Overload, IP68

HY-PGD-M is a column load cell, 2 t to 50 t in 6 steps, for batching in chemical, steel and pharmaceutical plants. Stainless steel, welded seal, IP68, low profile, 6-wire, 13 m cable. Its sensitivity and overload figures are the most unusual in this range — sensitivity 1.0 (most are 2.0), safe overload 200% and ultimate 500% (most are 150% / 300%).

Not sure about the step or the indicator match:

+86 183 5123 8137

Short answer: HY-PGD-M covers 2, 5, 10, 20, 30 and 50 t; column, stainless steel, welded seal, IP68, low profile; wiring is 6-wire (green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense); sensitivity 1±0.002 mV/V, input 695±7 Ω, output 600±2 Ω, non-linearity ≤0.01, operating range -40 to +65 °C, safe overload 200%, ultimate 500%, cable 13 m.

Why are its sensitivity and overload the most unusual here?

Short answer: sensitivity 1±0.002 mV/V — the only 1.0 in this range (others are 2.0 or 1.94); safe overload 200% and ultimate 500% — the highest here (most are 150% / 300%). Together those two point at heavy load with impact — and the industries named include steel.

Sensitivity and overload across models here (company documentation)
Model Sensitivity (mV/V) Safe / ultimate overload
HY-PGD-M (this page) 1±0.002 200% / 500%
HY-0743-M / HY-0745A-M 1.94±0.002 150% / 300%
HY-SB-M / HY-SBD / HY-QS and most others 2±0.002 150% / 300%
HY-QS (40-50 t steps) 2±0.002 120% / 200%

⚠️ What sensitivity 1.0 means in practice: at the same load, this cell's output is half that of a 2.0 model. So ① the indicator needs more resolution / a smaller minimum division (a smaller signal means noise takes a bigger share); ② it cannot be dropped in where a 2.0 cell was — the output differs by a factor of two, so it must be recalibrated and the indicator range checked; ③ do not parallel it with a 2.0 model, or the load splits badly. On the other hand, 200%/500% overload buys impact margin, which steel and heavy batching need more.

How does it split from HY-GD-M?

Short answer: both are column, stainless, IP68, but the capacity band, sensitivity and overload are completely different. HY-GD-M runs 15–100 t at sensitivity 2.0; this one runs 2–50 t at 1.0 with higher overload.

The two column models here (company documentation)
Item HY-PGD-M (this page) HY-GD-M
Capacity 2 to 50 t (6 steps) 15 to 100 t (5 steps)
Sensitivity 1±0.002 2±0.002
Overload (safe / ultimate) 200% / 500% 150% / 300%
Resistance (in / out) 695±7 / 600±2 1160±10 / 1000±3
Protection / material IP68 / stainless IP68 / stainless (same)
Industries named chemical, steel, pharmaceutical vehicle weighing, rail weighing, heavy batching

⚠️ Selection: ① column type at 2–10 t — only this model; ② 100 t — only HY-GD-M; ③ heavy impact — this model has one step more overload margin; ④ note the sensitivity differs by a factor of two, so indicator and calibration follow the actual model.

How is it wired?

Short answer: 6-wire. The text and the drawing agree wire for wire.

6-wire colour code (text and drawing agree)
Colour Function Terminal name
Green+ excitationExcitation(+)
Black− excitationExcitation(−)
White+ signalSignal(+)
Red− signalSignal(−)
Yellow+ senseSense(+)
Blue− senseSense(−)
pale-yellowshieldShield

⚠️ Here it is green = excitation+, white = signal+, red = signal−, not the 4-wire HY-1241 order (red = excitation+), so never carry a colour order across models. The cable is 13 m — a long run; connect the sense pair, or the 13 m drop goes straight into the reading. Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below.

HY-PGD-M specifications (company documentation)
Parameter Unit Value
SensitivitymV/V1±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.01
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-40 to +65
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ695±7
Output resistanceΩ600±2
Insulation resistanceMΩ5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.200
Ultimate overload%R.C.500
Protection—IP68
Cable lengthm13

The insulation cell reads "5000" with no "≥" sign in the original; it is transcribed as written.

What are the dimensions?

Short answer: the drawing carries actual numbers (more complete than the sibling column model HY-GD-M, whose drawing has symbols only). Units are unmarked and none are added here.

Dimension callouts (from the drawing, units unmarked)
Part Values shown
Overall height 118.6
Body diameter Φ76
Width 102
Other centre bore Φ40; bottom boss height 10; top ball diameter ΦA (shown as a symbol); cable exit 20

⚠️ Two notes: ① the top diameter is the symbol ΦA with no number on the drawing — that value is left out here; ② the rest are actual numbers, transcribed. Verify against the original drawing before machining.

What does it look like?

Short answer: four images are supplied — a product photograph, a wiring diagram and a dimension drawing. Three are used here.

HY-PGD-M column load cell: stainless-steel cylinder with a domed top boss, cable leaving the side; factory watermark
Column body with a domed load button, cable from the side. Company documentation.
HY-PGD-M column dimension drawing: two views with overall height 118.6, Φ76, width 102, Φ40, bottom boss 10
Dimension drawing (with actual numbers). Company documentation.
HY-PGD-M wiring diagram: Green excitation+, Yellow sense+, White signal+, Black excitation-, Blue sense-, Red signal-, pale-yellow shield
Wiring diagram (6-wire plus shield). Company documentation.

Where does it fit, and where does it not?

Short answer: the documented applications are batching in chemical, steel and pharmaceutical plants, 2 to 50 t. The "steel" industry does not appear on any other model's page here.

The industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete plant.

How can I tell whether the cell has failed?

Short answer: input across green/black 695±7 Ω, output across white/red 600±2 Ω, insulation to body 5000 MΩ (as written, no "≥").

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure green / black Around 695±7 Ω; open circuit means a broken internal wire
2 Measure white / red Around 600±2 Ω
3 Measure insulation to body 5000 MΩ range; a clear drop means moisture or a damaged seal

⚠️ Do not borrow HY-GD-M (1160/1000) or HY-SBD (772/700) references — this model is 695/600. Also: normal resistances do not prove the sensitivity is right — at 1.0, fitting a 2.0 spare can leave resistances normal but the output doubled.

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: load per cell and cell count, indicator model (it must suit sensitivity 1.0), impact severity (how material is dropped), mounting form, whether IP68 is needed, and any height limit.

Call +86 183 5123 8137