First published · Chinese version: HY-GD-M 称重传感器

You are here: Home > Products > HY-GD-M

HY-GD-M Load Cell: Column Type, 15 t to 100 t, Stainless IP68, 6-Wire

HY-GD-M is a column load cell (the documentation calls it a "self-stabilising rocker column"), 15 t to 100 t in 5 steps, for vehicle weighing, rail weighing and heavy batching. Stainless steel, welded seal, IP68, low profile, 6-wire, 13 m cable. Its input and output resistances are two to three times those of the other models here — check the indicator against them.

Not sure about the step or the indicator match:

+86 183 5123 8137

Short answer: HY-GD-M covers 15, 20, 30, 50 and 100 t; column type, stainless steel, welded seal, IP68, low profile; wiring is 6-wire (green = +excitation, black = −excitation, white = +signal, red = −signal, yellow = +sense, blue = −sense); sensitivity 2±0.002 mV/V, input 1160±10 Ω, output 1000±3 Ω, non-linearity ≤0.01, operating range -40 to +65 °C, safe overload 150%, ultimate 300%, cable 13 m.

Why is its resistance the highest here, and why check the indicator?

Short answer: input 1160±10 Ω, output 1000±3 Ω — two to three times the other models on this site (most are 350–772 Ω). That is not a typo; it is a common choice for large column cells, but it places real requirements on the indicator.

Input / output resistance across models here (company documentation)
Model Input Output
HY-GD-M (this page) 1160±10 Ω 1000±3 Ω
HY-SBD 772±4 Ω 700±1 Ω
HY-QS 750±10 Ω 703±2 Ω
HY-1022 / HY-1241 / HY-SSP1022 / HY-SSP1241 and similar 400±10 Ω 350±4 Ω
HY-SB-M / HY-SBC-M / HY-SBH-M and similar 381±4 Ω 350±1 Ω

⚠️ Why this matters: a higher cell output resistance means more voltage division at the indicator input and more noise pickup. When selecting or replacing, confirm: ① the indicator's input impedance is far above 1000 Ω (most weighing indicators are 10 MΩ and up, but older or special units should be checked); ② do not parallel it with low-resistance models (381/350) — the output splits by resistance and calibration becomes difficult; ③ the fault-check reference here is 1160 / 1000 — borrowing 381/350 will fail a good cell.

What is it, and how does it split from the other high-capacity models?

Short answer: this is a column; HY-SBD and HY-QS are double shear beams. The three differ in outline and mounting: a column is a cylinder loaded through top and bottom bosses; a double shear beam is a long bar fixed at both ends and loaded in the middle.

The three high-capacity models here (company documentation)
Model Type Capacity Resistance (in/out) Protection
HY-GD-M (this page) column 15–100 t (5 steps) 1160 / 1000 IP68
HY-SBD double shear beam 15–50 t (5 steps) 772 / 700 IP67
HY-QS double shear beam 15–50 t (5 steps) 750 / 703 IP67 (5 t) / IP68 (10-50 t)

⚠️ Three rules: ① above 50 t (up to 100 t) only this model; ② IP68 at capacities up to 100 t — this is the only choice; ③ column vs double shear beam follows the mounting: a column suits vertical loading through aligned top and bottom bosses (as in a vehicle-scale load bearing), a double shear beam suits a long platform fixed at both ends. The documentation also claims "low profile, quick to install", an advantage in retrofits.

How is it wired?

Short answer: 6-wire. The text and the drawing agree wire for wire.

6-wire colour code (text and drawing agree)
Colour Function Terminal name
Green+ excitationExcitation(+)
Black− excitationExcitation(−)
White+ signalSignal(+)
Red− signalSignal(−)
Yellow+ senseSense(+)
Blue− senseSense(−)
pale-yellowshieldShield

⚠️ Here it is green = excitation+, white = signal+, red = signal−, not the 4-wire HY-1241 order (red = excitation+), so never carry a colour order across models. The cable is 13 m — a long run; this model has a sense pair, and if the sense wires are not connected the 13 m drop goes straight into the reading. Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below. Note non-linearity ≤0.01, tighter than the ≤0.02 of most siblings.

HY-GD-M specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.01
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-40 to +65
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ1160±10
Output resistanceΩ1000±3
Insulation resistanceMΩ5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP68
Cable lengthm13

The insulation cell reads "5000" with no "≥" sign in the original; it is transcribed as written.

What are the dimensions?

Short answer: the drawing carries symbols only, no numbers. It labels parts A, B, C, D, E, F and ΦA, ΦC, Φ40, Φ50 — without giving the value behind any symbol; the numbers have to be looked up per capacity.

Symbols on the drawing and the parts they mark (no values)
Symbol Part
Eoverall height (between top and bottom bosses)
Ftop / bottom boss height
ΦAbody outside diameter
B / D / ΦCbottom width / bottom nut across flats / top diameter
Φ40 / Φ50side boss diameter / centre bore

⚠️ Why no numbers: the drawing has symbols but no value table. This page will not estimate — dimensions are used for machining and alignment, and an estimated number moves the risk onto the customer. Ask us for the drawing of this model and state the exact capacity (15/20/30/50/100 t).

What does it look like?

Short answer: three images are supplied — one product photograph, one wiring diagram and one dimension drawing (symbols only). All three are used here.

HY-GD-M column load cell: stainless-steel cylinder with top and bottom bosses, cable leaving the side; factory watermark
Column body with top and bottom bosses, cable from the side. Company documentation.
HY-GD-M wiring diagram: Green excitation+, Yellow sense+, White signal+, Black excitation-, Blue sense-, Red signal-, pale-yellow shield
Wiring diagram (6-wire plus shield). Company documentation.
HY-GD-M column dimension drawing: two views labelled with symbols E/F/ΦA/B/D/ΦC/Φ40/Φ50 and no numeric values
Dimension drawing (symbols only, no values). Company documentation.

Where does it fit, and where does it not?

Short answer: the documented applications are vehicle weighing, rail weighing and heavy batching, 15 to 100 t.

The equipment types named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across green/black 1160±10 Ω, output across white/red 1000±3 Ω, insulation to body 5000 MΩ (as written, no "≥").

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure green / black Around 1160±10 Ω; open circuit means a broken internal wire
2 Measure white / red Around 1000±3 Ω
3 Measure insulation to body 5000 MΩ range; a clear drop means moisture or a damaged seal

⚠️ Do not borrow HY-SBD (772/700) or HY-QS (750/703) references — this model is 1160/1000, and the wrong reference will fail a good cell. On a parallel bank, disconnect the other cells before measuring one.

Where do the facts come from?

Dimensions are omitted because the drawing shows symbols without a value table.

Still unsure which step fits?

Tell us: load per cell and cell count, mounting form (load-bearing seat or long platform), indicator model (its input must suit a 1000 Ω output), whether the site stands wet, and any height limit.

Call +86 183 5123 8137