HY-FWC-M Weighing Module: 0.22 t to 20 t in 7 Steps, Stainless Steel, IP68

HY-FWC-M is a stainless-steel weighing module covering 0.22 t to 20 t in 7 capacity steps. The module combines the load cell with a top plate, a base plate and a support column into one unit. It mounts under the feet or brackets of a tank, reactor or vessel, turns weight into an electrical signal for the weight indicator, and is documented for batching control on tanks in harsh environments.

If you are unsure which step you need, describe the duty:

+86 183 5123 8137

One tap to call; no form to fill in.

Short answer: HY-FWC-M covers 0.22 t, 0.55 t, 1.1 t, 2.2 t, 9 t, 13.6 t and 20 t in 7 steps; it uses a stainless-steel hermetically sealed load cell with IP68 protection; it is a 6-wire plus shield module. Dimensions fall into 4 groups (0.22–2.2 / 4.4 / 9.07–13.6 / 20.4), given by side and end dimension drawings and one per-step dimension table with 10 letters. All values are transcribed from the company product documentation, with the source marked on each row.

Values are the company product documentation as printed; every field on this page carries its source in the tables.

What is HY-FWC-M, and where does it mount?

Short answer: a weighing module is a structural accessory for a load cell, built from a top plate, a base plate, the load cell, a load-bearing column and support bolts; it brings the load cell, the load-transfer parts and the mounting plates together as one unit. (Public technical literature, Selection and Installation of Weighing Modules.)

Modules usually mount at the bottom of the scale body — under the feet, the pallet or the like — or on top of it, on the waist of a reactor, tank or hopper. All modules of one weighing system must sit in the same horizontal plane. (Public technical literature, Selection and Installation of Weighing Modules.)

The company documentation describes HY-FWC-M as: a distinctive structure that mounts easily on all kinds of tanks; support bolts that prevent the equipment from tipping over; simple, quick installation; easy maintenance that saves downtime. The matching field action is: mount the module under the tank foot or bracket, fix module and foot together with the support bolts, and loosen those bolts for service. (Company product documentation.)

What are the three structural types, and which one is HY-FWC-M?

By public industry documentation, weighing modules fall into three types according to the load-bearing column and top plate: fixed, semi-floating and floating. In one weighing system, one fixed module and one semi-floating module are used and the rest are floating; sets are usually three modules for three-point support or four modules for four-point support. (Public technical literature, Selection and Installation of Weighing Modules.)

The company documentation does not state which of the three types HY-FWC-M is, so this page does not classify it. The division of work between the three types and the criteria for telling them apart are on the fixed weighing module page; where the structure decides the selection, use that page and the shipping documentation. (Basis: the company documentation records no structural class for this model.)

Where does it sit in a weighing system?

A weighing control system usually consists of a weight indicator, a junction box, the weighing modules and the cable. The modules carry the load, the junction box sums the signals from several modules, and the indicator displays and controls. (Company installation instructions.)

One system usually uses 3 to 6 modules (12 at most) as a set. The foundation must meet a stiffness requirement and lie in one horizontal plane, or be adjustable to one, so that every module carries an equal share. (Company installation instructions.)

What are the specifications, and where does each value come from?

Short answer: the table lists each documented value with its source; the right-hand column turns the value into what has to be judged at selection and installation. Values are transcribed as printed — no conversion, no merging, and no steps added that the documentation does not contain.

HY-FWC-M specifications, sources, and what each value determines
Parameter Value (source) What it determines
Model HY-FWC-M Company documentation The identifier used for ordering. Other suffixes in this family differ in material and wiring, so quote the full suffix and confirm against the shipping documentation.
Category Weighing module Company documentation A structural part plus a load cell. Capacity, material and mounting dimensions all matter together; comparing load cell figures alone is not enough.
Capacity steps 0.22 t, 0.55 t, 1.1 t, 2.2 t, 9 t, 13.6 t, 20 t Company documentation (7 steps, transcribed as printed) The maximum load one module carries. Total system capacity = rated capacity × number of modules, so calculate vessel dead weight and product weight first, then take the next step up.
Material and sealing Stainless-steel hermetically sealed load cell Company documentation A welded, sealed stainless housing is one precondition for damp workshops that are washed down; for aggressive media or high temperature the documentation gives no rating, so confirm against the duty.
Protection IP68 Company documentation The two digits are dust and water protection. IP68 allows short immersion, so the module body can take washdown or brief immersion; whether the whole weighing circuit can be washed still depends on the cable entry and the junction box meeting the same level — a new module alone does not keep water out of the box. (Reading of the digits: public technical literature.)
Structural features Mounts easily on all kinds of tanks; support bolts prevent tipping; simple, quick installation; easy maintenance, saves downtime Company documentation "Mounts easily on all kinds of tanks" decides how well it suits the existing feet; "support bolts prevent tipping" means room must be left to fix and adjust them; "easy maintenance" means service space below the foot. In practice, measure the existing hole pattern and the available height first, then pick the dimension group against the drawings.
Wiring system 6-wire plus shield (+excitation / −excitation / +signal / −signal / +sense / −sense, and one shield wire) Company documentation and company specification drawing Decides how many conductors run from module to junction box and how many terminals to leave. The sense pair is what a 4-wire module lacks: it puts back the excitation drop along a long cable, so when the run to the indicator is long, terminate it at the sense terminals of the indicator or junction box. The shield suppresses interference from drives and power cables: earth it at one end and keep signal cables away from power cables. (Principle and practice: public technical literature.)
Colour code Green = +excitation; black = −excitation; white = +signal; red = −signal; yellow = +sense; blue = −sense (6 wires). The wiring diagram in the specification drawing also marks pale yellow = shield. Company documentation and company specification drawing Field wiring reference. Wiring differs between suffixes of the same family and between batches, so work to the shipping documentation and the wiring diagram of the unit in hand; do not copy colours across models.
Wiring diagram Green = excitation+; yellow = sense+; white = signal+; black = excitation−; blue = sense−; red = signal−; pale yellow = shield Company specification drawing (drawing 3 below) One wire more than the text above: the shield. The order printed on the drawing corresponds wire by wire to the two rows above; check terminal numbers against the drawing before powering up.
Dimensions 4 groups by capacity (0.22–2.2 / 4.4 / 9.07–13.6 / 20.4); side and end dimension drawings plus one per-step dimension table, 10 letters in all: A, B, C, D, E, F, G, H, J, K Company specification drawing (drawings 4, 5 and 6 below) Changing the capacity step also changes the outline and the mounting holes: it moves the support points and the foundation size. Fix the capacity step before modifying feet or casting a foundation, then check hole pitch and overall height of that group against the available space. The values for the letters are in the drawing and are not copied a second time here; the drawing states no unit, so it is reproduced as printed. The capacity list on the product page and the groups in the drawing's dimension table do not match one to one — the table has additional 4.4 and 20.4 groups. Both are reproduced here and are not merged for the customer; confirm the order against the shipping documentation and the unit in hand.
Documented applications Suitable for batching control on tanks in harsh environments Company documentation A direction of application, not a promise that any harsh environment will do. For a given machine, check vessel dead weight, product weight, number of feet and site conditions.

Values and wording are transcribed from the company documentation, including the fact that a value is missing. Every reading on this page carries its own source and comes from public technical literature, not from a company commitment. The company documentation states no overall accuracy or long-term stability figure for this model; none is inferred and none is published here. The table has 11 rows, one for each of the 11 fields the documentation records.

Which capacity step fits which duty, and how do the dimension groups relate to the capacity steps?

Short answer: check the single-module rating against "dead load + live load ≤ rated capacity × number of modules × 70%", then take the next step up; the number of modules follows the number of support points. (Criterion from public technical literature.)

dead load + live load ≤ rated capacity × number of modules × 70%

The formula is repeated in words so it can be copied, sent to a work group or printed for a design office. Worked examples are on the Selection & Resources page.

Case by case, what do I take?

HY-FWC-M: which step and how many modules, case by case
Your case What to take Basis
The vessel already has support feet One module per foot: 3 feet, 3 modules; 4 feet, 4 modules Public technical literature
The single-module rating falls between two steps Take the next step up; never down Public technical literature
How many modules, and how are the structures combined? One fixed module and one semi-floating module, the rest floating; three-module and four-module sets are common Public technical literature
Product is fed into the vessel horizontally Where product is fed vertically by conveyor or pump into hoppers, tanks, reactors and vessels, use static-load modules; where it is fed horizontally onto the scale or into the vessel, the horizontal impact calls for dynamic-load modules Public technical literature, Selection and Installation of Weighing Modules
The site is damp and needs washdown This model uses a stainless-steel hermetically sealed load cell with IP68; treat the junction box and cable entries to the same level at the same time Values from company documentation; practice from public technical literature
The module is far from the indicator Use the sense wires of the 6-wire system to compensate cable drop, wired to the matching terminals in the table above Principle from public technical literature
Replacing an old module without changing the foundation Measure the existing hole pattern and the available height first, then pick the same dimension group from the drawings on this page Dimensions from the company specification drawing
The capacity list says 9 / 13.6 / 20 t, the dimension table says 9.07–13.6 and 20.4 Both are reproduced and not merged: choose the rated capacity from the capacity list first, then find that group's hole pitch and overall height in the dimension table; confirm the order against the shipping documentation and the unit in hand Company documentation and company specification drawing, both as printed

Why do the capacity list and the dimension table not match one to one?

The product page of the company documentation gives 7 capacity steps: 0.22 t, 0.55 t, 1.1 t, 2.2 t, 9 t, 13.6 t and 20 t. The per-step dimension table in the company specification drawing gives 4 groups: 0.22–2.2, 4.4, 9.07–13.6 and 20.4. The two are not one to one; the dimension table carries the additional 4.4 and 20.4 groups.

The capacity list on the product page and the groups in the dimension table of the drawing do not correspond one to one. Both are reproduced here and are not merged for the customer; confirm the order against the shipping documentation and the unit in hand. These are the two printed facts; nothing is converted here and neither is dropped.

Where does it fit, and where does it not?

Short answer: what the company documentation and the sourced statements on this page support is batching control on tanks in harsh environments, plus the damp, washdown duty implied by a stainless-steel hermetically sealed load cell with IP68. Where the documentation gives nothing — overall accuracy, long-term stability, material grade, temperature range, corrosion class — this page neither infers a value nor decides for the customer.

Fits (documented)

Limits and what does not fit

What do the specification drawings show, and why is there no photograph of this model?

Short answer: the six drawings below are the company specification drawings for this model — mounting arrangement, layout with the three structural types, the 6-wire wiring diagram, side and end dimension drawings, and the per-step dimension table. The files are local; the page loads no external resource. No usable photograph of the actual unit was available for this model at the time of writing; for the physical appearance, use the drawings and the shipping documentation.

HY-FWC-M specification drawing: mounting arrangement, five panels showing different module layouts and mounting attitudes
Drawing 1 — mounting arrangement: five panels showing different module layouts and mounting attitudes. Company specification drawing.
HY-FWC-M specification drawing: layout with rectangular and radial arrangements at 90 and 120 degrees, and fixed, semi-floating and floating structures
Drawing 2 — layout: rectangular and radial arrangements (90° / 120°), with fixed, semi-floating and floating structures. The three types are an industry classification; the company documentation does not say which one this model is. Company specification drawing.
HY-FWC-M specification drawing: 6-wire plus shield wiring diagram marking excitation, sense and signal pairs and the shield colour
Drawing 3 — wiring diagram: 6 wires plus shield; green = excitation+, yellow = sense+, white = signal+, black = excitation−, blue = sense−, red = signal−, pale yellow = shield. Company specification drawing.
HY-FWC-M specification drawing: side outline dimensions marked with letters and a diameter symbol
Drawing 4 — outline dimensions (side): letters A, E, G, 4-ØF, C, D, B, K. Values are in the dimension table below; the drawing states no unit, so it is reproduced as printed. Company specification drawing.
HY-FWC-M specification drawing: end outline dimensions marked with letters for heights and widths
Drawing 5 — outline dimensions (end): letters A, E, G, H, J. Values are in the dimension table below; the drawing states no unit, so it is reproduced as printed. Company specification drawing.
HY-FWC-M specification drawing: dimension table by capacity in four groups, giving values for letters A to K
Drawing 6 — dimension table by capacity: headed "capacity (t)", 4 groups (0.22–2.2 / 4.4 / 9.07–13.6 / 20.4), values for the 10 letters A, B, C, D, E, F, G, H, J, K. The table states no unit; it is reproduced as printed and is not copied again on this page. Company specification drawing.

The six drawings are company product images used unaltered. No usable photograph of this model was available at the time of writing; for the physical appearance, use the drawings and the shipping documentation. Where a drawing and the written documentation disagree, the written documentation governs.

What matters during installation and wiring?

Short answer: three things decide whether the modules work — foundation stiffness and level, verticality of the connections, and whether outside forces such as piping and welding have been taken off the load path. Each item below carries a figure or an action you can check; the source of the general items is public installation literature.

Installation and wiring requirements, item by item with source
Item Requirement Source
Verticality All module axes in line with the perpendicular to the mounting plate, deviation not more than 1.5°; correct with shims if it is out Company installation instructions
Frame and base stiffness Frame and base plate carrying the modules must be stiff enough; stiffness of 1/1000 is required Company installation instructions
Bracket skew Skew or twist of the upper bracket and the base bracket to the horizontal must not exceed 0.5° Public technical literature, Selection and Installation of Weighing Modules
Foundation The foundation or floor carrying the tank must have enough strength and stiffness; deflection below 3 mm; a concrete foundation is a good choice Public technical literature, Selection and Installation of Weighing Modules
Levelling After mounting, rock the top plate by hand; if it moves, the module is not level — shim it until it does not Company installation instructions
Bolting Tighten all bolts diagonally, pre-tighten first, then torque to specification Company installation instructions
Welding No current may pass through the weighing module during welding; no other current (arc welding, for instance) may pass through the load cell Company installation instructions
Cable Do not stretch the cable, because tension affects electrical performance; protect the cable from cuts Company installation instructions
Handling Never lift the module by its cable; avoid knocks and drops from height Company installation instructions
Piping Run all pipes connected to the tank horizontally so they do not hang it; prefer flexible connections and keep the first support point as far from the tank as possible Public technical literature, Selection and Installation of Weighing Modules
Earthing One independent earth per module Public technical literature, Selection and Installation of Weighing Modules
Wiring and checks before power-up Connect the load cell cable to the junction box as the wiring diagram shows; re-check the wiring and verify that the supply voltage is normal Company installation instructions
Calibration conditions Allow test-weight positions and jacking points for installation and service at the design stage; calibrate after installation Public technical literature, Selection and Installation of Weighing Modules

The table lists general requirements from public installation literature and applies to this class of module; site practice and the final decision remain with the shipping documentation and the actual duty.

Where do the facts on this page come from?

Values in the tables are transcribed from company documentation and are not a commitment for a specific project; confirm the specification against the duty. Dates and wording on this page follow the header and footer.

Still unsure which capacity step fits?

Tell us these in one go and we can suggest capacity and module count directly: vessel dead weight, product weight, number and layout of support feet, product name and characteristics, site conditions, and whether it is a new build or a retrofit.

Call +86 183 5123 8137