How does it differ from HY-SBS?
Short answer: the electrical parameters are identical, but there are two real differences. First, the capacity steps (3 here; SBS has 4, including a 3 t step). Second, the outline is a different one — this is not a rename; if it does not fit, it does not fit.
| Item | HY-SBT (this page) | HY-SBS |
|---|---|---|
| Capacity | 0.5, 1, 2 t (3 steps) | 0.5, 1, 2, 3 t (4 steps) |
| Wiring | 4-wire | 4-wire (same) |
| 19 parameters | Item-for-item same as SBS | Item-for-item same as SBT |
| Features | 6 lines (same text as SBS) | 6 lines (same) |
| Outline (drawing) | Overall 137, width 50.6; thread M12; Φ26, 2-Φ13 | Overall 92, width 50; thread M8; different holes |
| Dimension table | No capacity table (one set of callouts) | Has an L8 table (18 / 16) |
⚠️ This point matters most: the two are electrically interchangeable but not mechanically. The length differs by 45 and the mounting thread goes from M8 to M12 — a base plate drilled for SBS will not take an SBT. Check the mounting space and thread first, then the capacity.
How is it wired?
Short answer: 4-wire. The text, the label on the unit, and the drawing all agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | EXC+ / +input | + excitation |
| Black | EXC− / −input | − excitation |
| Green | SIG+ / +output | + signal |
| White | SIG− / −output | − signal |
| Thick yellow | SHIELD | shield |
The label on the unit writes the shield as SHIELD (Thick Yellow) while the drawing writes pale-yellow — two ways of writing the same thing. Both are transcribed. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-SBS, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 3 |
Upper operating limit +60 °C.
What are the dimensions?
Short answer: one set of callouts, no capacity table (unlike HY-SBS). Units are not marked and none are added here.
| View | Values shown |
|---|---|
| Side | Overall 137, height 34.1, 39, 45, 20.8; thread M8 (cable end) |
| Top | Width 50.6, 38.4, 78.2, 20.4; holes Φ26, 2-Φ13; mounting thread M12 |
⚠️ Against the HY-SBS drawing: SBS is overall 92 / width 50 / M8 at both ends; this one is overall 137 / width 50.6 / mounting thread M12 — the two cannot be swapped for installation. The drawing carries both M8 and M12 threads (cable end and mounting side); do not mix them when ordering bolts.
What does it look like?
Short answer: five images are supplied — three product photographs, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.
⚠️ Archive note: all five images sit in the "product photo" folder on the old site, but two are actually drawings. This page uses them by what they are.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and building-material batching control, 0.5 to 2 t. The difference from HY-SBS is not the duty — it is the mounting.
- Fits: ground-level platforms and building-material lines where the mounting space and holes match this drawing (overall 137, M12).
- Capacity limit: 0.5 to 2 t — one step less than HY-SBS (which goes to 3 t).
- ⚠️ Mounting comes first: electrically interchangeable with SBS, mechanically not. A base plate made for SBS will not accept an SBT.
- Not covered: the 3 t step (use SBS); small bench platforms (single point); vessel batching (column modules); high-capacity platforms (double shear beam).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The reference values are the same as HY-SBS (381 / 350), so the test is shared; the mounting is not.
Where do the facts come from?
- Company product documentation: six features, 4-wire colour code, 3 capacity steps, 19 technical parameters.
- Company images (five): three product photographs (one used), a dimension drawing, and a wiring diagram.
- Item-by-item check against HY-SBS: both pages and both drawings compared (same parameters; different capacity steps and outline).
- Public technical literature: mounting stiffness for batching, hole-pattern selection for bar-type cells.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: the hole pattern and thread of the existing base or legs (this is what separates SBT from SBS), load per cell and cell count, mounting height, how material is dropped, and the temperature range.