First published · Chinese version: HY-SBT 称重传感器

You are here: Home > Products > HY-SBT

HY-SBT Load Cell: 0.5 t to 2 t, 4-Wire

HY-SBT is a low-profile load cell rated 0.5 t to 2 t, for batching control on ground-level platforms and building-material lines. Alloy steel, nickel-plated, IP67, 4-wire, 3 m cable. Its electrical parameters match HY-SBS item for item, but the mechanical outline is a different one — different length, different mounting thread.

Not sure between SBT and SBS — tell us your mounting hole pattern:

+86 183 5123 8137

Short answer: HY-SBT covers 0.5, 1 and 2 t in 3 steps; low mounting height, alloy steel nickel-plated, IP67; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity 2±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, safe overload 150%, ultimate 300%, cable 3 m.

How does it differ from HY-SBS?

Short answer: the electrical parameters are identical, but there are two real differences. First, the capacity steps (3 here; SBS has 4, including a 3 t step). Second, the outline is a different one — this is not a rename; if it does not fit, it does not fit.

HY-SBT vs HY-SBS (both pages of documentation plus both drawings)
Item HY-SBT (this page) HY-SBS
Capacity 0.5, 1, 2 t (3 steps) 0.5, 1, 2, 3 t (4 steps)
Wiring 4-wire 4-wire (same)
19 parameters Item-for-item same as SBS Item-for-item same as SBT
Features 6 lines (same text as SBS) 6 lines (same)
Outline (drawing) Overall 137, width 50.6; thread M12; Φ26, 2-Φ13 Overall 92, width 50; thread M8; different holes
Dimension table No capacity table (one set of callouts) Has an L8 table (18 / 16)

⚠️ This point matters most: the two are electrically interchangeable but not mechanically. The length differs by 45 and the mounting thread goes from M8 to M12 — a base plate drilled for SBS will not take an SBT. Check the mounting space and thread first, then the capacity.

How is it wired?

Short answer: 4-wire. The text, the label on the unit, and the drawing all agree.

4-wire colour code (text / unit label / drawing agree)
Colour Terminal Function
RedEXC+ / +input+ excitation
BlackEXC− / −input− excitation
GreenSIG+ / +output+ signal
WhiteSIG− / −output− signal
Thick yellowSHIELDshield

The label on the unit writes the shield as SHIELD (Thick Yellow) while the drawing writes pale-yellow — two ways of writing the same thing. Both are transcribed. Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, identical to HY-SBS, transcribed below.

HY-SBT specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm3

Upper operating limit +60 °C.

What are the dimensions?

Short answer: one set of callouts, no capacity table (unlike HY-SBS). Units are not marked and none are added here.

Dimension callouts (from the drawing)
View Values shown
SideOverall 137, height 34.1, 39, 45, 20.8; thread M8 (cable end)
TopWidth 50.6, 38.4, 78.2, 20.4; holes Φ26, 2-Φ13; mounting thread M12

⚠️ Against the HY-SBS drawing: SBS is overall 92 / width 50 / M8 at both ends; this one is overall 137 / width 50.6 / mounting thread M12 — the two cannot be swapped for installation. The drawing carries both M8 and M12 threads (cable end and mounting side); do not mix them when ordering bolts.

What does it look like?

Short answer: five images are supplied — three product photographs, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.

HY-SBT load cell: natural alloy-steel bar body, cable leaving one end, a wiring label on the side (EXC+ red, EXC- black, SIG+ green, SIG- white, SHIELD thick yellow); factory watermark
The label on the body is a wiring diagram, not a nameplate. Company documentation.
HY-SBT dimension drawing: side 137/34.1/39/45/20.8 with M8; top 50.6/38.4/78.2/20.4, Φ26, 2-Φ13, M12
Dimension drawing (one set of callouts, no capacity table). Company documentation.
HY-SBT wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

⚠️ Archive note: all five images sit in the "product photo" folder on the old site, but two are actually drawings. This page uses them by what they are.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms and building-material batching control, 0.5 to 2 t. The difference from HY-SBS is not the duty — it is the mounting.

How can I tell whether the cell has failed?

Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

The reference values are the same as HY-SBS (381 / 350), so the test is shared; the mounting is not.

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: the hole pattern and thread of the existing base or legs (this is what separates SBT from SBS), load per cell and cell count, mounting height, how material is dropped, and the temperature range.

Call +86 183 5123 8137