First published · Chinese version: HY-SBS 称重传感器

You are here: Home > Products > HY-SBS

HY-SBS Load Cell: 0.5 t to 3 t, 4-Wire

HY-SBS is a low-profile load cell rated 0.5 t to 3 t, for batching control on ground-level platforms and building-material lines. Alloy steel, nickel-plated, IP67, 4-wire without a sense pair, 3 m cable. Against the sibling HY-SBS-M it differs in two things only: the wiring and one feature line; everything else is the same.

Not sure between 4-wire and 6-wire — tell us which indicator you have:

+86 183 5123 8137

Short answer: HY-SBS covers 0.5, 1, 2 and 3 t in 4 steps; low mounting height, alloy steel nickel-plated, IP67; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal), no sense pair; sensitivity 2±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, safe overload 150%, ultimate 300%, cable 3 m.

How does it differ from HY-SBS-M?

Short answer: two things. The wiring (this one 4-wire, the M 6-wire) and the feature list (the M lists "self-stabilising structure", this one does not). Capacities, all 19 parameters and the dimensions are identical.

HY-SBS vs HY-SBS-M (both pages of documentation)
Item HY-SBS (this page) HY-SBS-M
Wiring 4-wire: red +excitation, black −excitation, green +signal, white −signal 6-wire: adds yellow +sense, blue −sense
Features 6 lines (no "self-stabilising structure") 7 lines (includes it)
Capacity 0.5 to 3 t, 4 steps 0.5 to 3 t, 4 steps, identical text
19 parameters Item-for-item identical to the M Item-for-item identical to the SBS
Dimensions Same drawing (18 / 16) Same drawing (18 / 16)

The documentation states no difference in capacity or in the 19 parameters. This page transcribes that as-is and does not decide for the customer which is "better". 4-wire or 6-wire depends on the indicator and the cable run — see below.

How is it wired, and what does 4-wire limit?

Short answer: 4-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.

4-wire colour code (text and drawing agree)
Colour Terminal Function
Red+input+ excitation
Black−input− excitation
Green+output+ signal
White−output− signal
pale-yellowShieldShield (drawing only)
4-wire vs 6-wire across this family
Situation What to choose
3 m cable is enough, indicator nearby 4-wire (this model) is fine; the drop is small
Cable must be extended Check the drop first; where it matters, use the 6-wire HY-SBS-M and let the indicator compensate
Indicator is a 6-wire type A 4-wire cell can be connected, but the compensation is then lost

Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, identical to HY-SBS-M, transcribed below.

HY-SBS specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm3

Upper operating limit +60 °C, lower -20 °C.

What are the dimensions?

Short answer: the drawing gives callouts plus a capacity-grouped L8 table. Units are not marked and none are added here.

Hole spacing by capacity (from the drawing)
Capacity L8
0.5 t / 1 t / 2 t18
3 t16
Other callouts (from the drawing)
View Values shown
Side40, 14, 30, 80, 92
Top50, 18.1, 45.7; thread M8

The drawing is identical to the HY-SBS-M one (same family, same outline). The 3 t step uses L8 = 16; the others use 18 — do not mix them.

What does it look like?

Short answer: five images are supplied — three product photographs, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.

HY-SBS load cell: natural alloy-steel bar body, cable leaving one end, a wiring label on the side listing red +excitation, black -excitation, green +signal, white -signal and thick yellow shield; factory watermark
The label on the body is a wiring instruction, not a nameplate. Company documentation.
HY-SBS dimension drawing: side 40/14/30/80/92, top 50/18.1/45.7, thread M8, with an L8 table (18 for 0.5-2 t, 16 for 3 t)
Dimension drawing (with the capacity-grouped L8 table). Company documentation.
HY-SBS wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

⚠️ Archive note: all five images sit in the "product photo" folder on the old site, but two are actually drawings. This page uses them by what they are.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms and building-material batching control. Both share two traits: platform loading, and dosing to a recipe.

How can I tell whether the cell has failed?

Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

The label on the body is a wiring instruction, not a parameter plate. If values are normal but the reading is unstable, work through installation, piping, junction box and supply first.

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: batching line type, load per cell and cell count, mounting height, how material is dropped, which indicator you use (this decides 4-wire or 6-wire), and the temperature range.

Call +86 183 5123 8137