How does it differ from HY-SBS-M?
Short answer: two things. The wiring (this one 4-wire, the M 6-wire) and the feature list (the M lists "self-stabilising structure", this one does not). Capacities, all 19 parameters and the dimensions are identical.
| Item | HY-SBS (this page) | HY-SBS-M |
|---|---|---|
| Wiring | 4-wire: red +excitation, black −excitation, green +signal, white −signal | 6-wire: adds yellow +sense, blue −sense |
| Features | 6 lines (no "self-stabilising structure") | 7 lines (includes it) |
| Capacity | 0.5 to 3 t, 4 steps | 0.5 to 3 t, 4 steps, identical text |
| 19 parameters | Item-for-item identical to the M | Item-for-item identical to the SBS |
| Dimensions | Same drawing (18 / 16) | Same drawing (18 / 16) |
The documentation states no difference in capacity or in the 19 parameters. This page transcribes that as-is and does not decide for the customer which is "better". 4-wire or 6-wire depends on the indicator and the cable run — see below.
How is it wired, and what does 4-wire limit?
Short answer: 4-wire. The text and the drawing agree wire for wire; the drawing adds pale-yellow = Shield.
| Colour | Terminal | Function |
|---|---|---|
| Red | +input | + excitation |
| Black | −input | − excitation |
| Green | +output | + signal |
| White | −output | − signal |
| pale-yellow | Shield | Shield (drawing only) |
| Situation | What to choose |
|---|---|
| 3 m cable is enough, indicator nearby | 4-wire (this model) is fine; the drop is small |
| Cable must be extended | Check the drop first; where it matters, use the 6-wire HY-SBS-M and let the indicator compensate |
| Indicator is a 6-wire type | A 4-wire cell can be connected, but the compensation is then lost |
Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-SBS-M, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 3 |
Upper operating limit +60 °C, lower -20 °C.
What are the dimensions?
Short answer: the drawing gives callouts plus a capacity-grouped L8 table. Units are not marked and none are added here.
| Capacity | L8 |
|---|---|
| 0.5 t / 1 t / 2 t | 18 |
| 3 t | 16 |
| View | Values shown |
|---|---|
| Side | 40, 14, 30, 80, 92 |
| Top | 50, 18.1, 45.7; thread M8 |
The drawing is identical to the HY-SBS-M one (same family, same outline). The 3 t step uses L8 = 16; the others use 18 — do not mix them.
What does it look like?
Short answer: five images are supplied — three product photographs, one dimension drawing and one wiring diagram. This page uses one photograph plus both drawings.
⚠️ Archive note: all five images sit in the "product photo" folder on the old site, but two are actually drawings. This page uses them by what they are.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and building-material batching control. Both share two traits: platform loading, and dosing to a recipe.
- Fits: ground-level platforms; building-material lines (aggregate, cement, sand); where mounting height is tight.
- Capacity limit: 0.5 to 3 t per cell.
- 4-wire limit: a 3 m cable is enough nearby; extensions need a drop check (use the 6-wire HY-SBS-M where compensation is required).
- Temperature limit: -20 to +60 °C — 5 °C lower at the top than most siblings.
- Not covered: small bench platforms (single point); vessel batching (column modules); high-capacity platforms (double shear beam).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
The label on the body is a wiring instruction, not a parameter plate. If values are normal but the reading is unstable, work through installation, piping, junction box and supply first.
Where do the facts come from?
- Company product documentation: six features, 4-wire colour code, 4 capacity steps, 19 technical parameters.
- Company images (five): three product photographs (one used), a dimension drawing with the capacity-grouped L8 table, and a wiring diagram.
- Item-by-item check against HY-SBS-M: both pages compared (wiring and feature list differ; capacity, parameters and dimensions do not).
- Public technical literature: mounting stiffness for batching, 4-wire vs 6-wire over long runs.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: batching line type, load per cell and cell count, mounting height, how material is dropped, which indicator you use (this decides 4-wire or 6-wire), and the temperature range.