Why are there two "HY-SQB" models, and why not mix them up?
Short answer: the documentation has two range versions of HY-SQB — this 100-300 kg one and a 0.5-5 t one. They share the same features, the same 4-wire code, the same 19 parameters and the same cable length; only the capacity differs. This is the most extreme same-name case on this site.
| Item | HY-SQB (100-300 kg, this page) | HY-SQB (0.5-5 t) |
|---|---|---|
| Capacity | 100 / 200 / 250 / 300 kg | 0.5 / 1 / 2 / 3 / 5 t |
| Features | 6 lines | 6 lines, word-for-word same |
| Wiring | 4-wire | 4-wire, same |
| Sensitivity | 2 / 3.0 (two values) | 2 / 3.0, same |
| Other parameters | 19 rows | 19 rows, item-for-item same |
| Cable | 3 m | 3 m, same |
⚠️ Why this is the highest-risk spot on the site: other "same parameters, different model" pairs at least carry different model numbers (HY-SBS-M vs HY-SBH-M); these two share even the model name and are distinguished only by the range in brackets. Check the range in three places: ① state "100-300 kg" or "0.5-5 t" on the purchase order; ② read the range on the nameplate at goods-in; ③ do not mix spares. This page does not decide which is "enough" — the ranges do not overlap, so pick by actual load.
Why two sensitivity values?
Short answer: the sensitivity cell carries two values — 2±0.002 and 3.0±0.002 — with no statement of which capacity step gets which. Both are transcribed; this page assigns neither. The same-name 0.5-5 t version is written the same way, and this two-value pattern recurs across HY-SQB, HY-HLJ-M and HY-SBH-M.
⚠️ Practical effect: cells with different sensitivity share the load in proportion to their sensitivity when paralleled, not equally. Mixing the two on one scale complicates calibration. Keep a batch consistent, or tell us which value you need.
How is it wired?
Short answer: 4-wire. The text and the drawing agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | EXC+ / +input | + excitation |
| Black | EXC− / −input | − excitation |
| Green | SIG+ / +output | + signal |
| White | SIG− / −output | − signal |
| thick black | SHIELD | shield |
⚠️ This is 4 wires plus one shield. The label on this unit writes the shield as "thick black" — note that siblings write "thick yellow", "long yellow" or pale-yellow, so work from the wire in hand, never copy a colour across models. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, item-for-item identical to the same-name 0.5-5 t version.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 / 3.0±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 3 |
What are the dimensions?
Short answer: the drawing gives one set of callouts (no capacity-grouped table — unlike the 0.5-5 t version). Units are unmarked, and some digits are small; only clearly readable values are transcribed.
| View | Values shown |
|---|---|
| Body | overall length 158, width 58, heights 31.8 / 25.1 |
| Holes | mounting holes 2-Φ8.5; centre spacing 78.2; right 25.4; left 15.7 |
| Other | centre bore Φ50; cable end 62 / 10.5 |
⚠️ Two notes: ① this version has no capacity table — all four steps share one set of callouts (the 0.5-5 t version has an 11-column table, so the drawings differ); ② units are unmarked and some digits are small — verify against the original drawing before machining.
What does it look like?
Short answer: four images are supplied — a product photograph, a wiring diagram and a dimension drawing. Three are used here.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and building-material batching, 100 to 300 kg.
The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: small-capacity batching; the small-ingredient stage on building-material lines; platforms with 100–300 kg per cell.
- Capacity limit: 100 to 300 kg. Above that, take the same-name 0.5-5 t version (starts at 0.5 t).
- ⚠️ Three things to confirm: ① which range version (100-300 kg or 0.5-5 t — same name); ② two sensitivity values; ③ shield colour (this label says thick black).
- Not covered: above 300 kg (same-name 0.5-5 t); 6-wire sense pair (HY-SBS-M / HY-SB-M); IP68 (HY-SBH-M / HY-HLJ-M).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
Resistances cannot tell sensitivity 2 from 3.0 — the resistances are identical. Check the nameplate or shipping documentation.
Where do the facts come from?
- Company product documentation: six features, 4-wire colour code, 4 capacity steps, 19 technical parameters.
- Company images (four): product photograph with a wiring label, wiring diagram, dimension drawing (no capacity table).
- Item-by-item check against the same-name 0.5-5 t version: both pages (parameters identical; only capacity differs).
- Public technical literature: how paralleled cells share load by sensitivity, 4-wire limits over long runs.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: load per cell (this decides the range version), platform size and construction, indicator model (4-wire or 6-wire), whether a specific sensitivity is required, and washdown conditions.