HY-SQB (100-300 kg) Load Cell: 100 kg to 300 kg, 4-Wire, Alloy Steel, IP67

HY-SQB (100-300 kg) is a small-capacity load cell, 100 kg to 300 kg in 4 steps, for ground-level platforms and building-material batching. Low profile, alloy steel nickel-plated, IP67, 4-wire, 3 m cable. ⚠️ The factory also sells a same-name HY-SQB (0.5-5 t); the two have identical parameters and differ only in capacity — check the range when ordering.

Confirm the range before ordering:

+86 183 5123 8137

Short answer: HY-SQB (100-300 kg) covers 100, 200, 250 and 300 kg; low profile, alloy steel nickel-plated, IP67; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity is given as two values (2±0.002 / 3.0±0.002); input 381±4 Ω, output 350±1 Ω, operating range -20 to +60 °C, safe overload 150%, ultimate 300%, cable 3 m.

Why are there two "HY-SQB" models, and why not mix them up?

Short answer: the documentation has two range versions of HY-SQB — this 100-300 kg one and a 0.5-5 t one. They share the same features, the same 4-wire code, the same 19 parameters and the same cable length; only the capacity differs. This is the most extreme same-name case on this site.

Two HY-SQB versions (both pages of documentation)
Item HY-SQB (100-300 kg, this page) HY-SQB (0.5-5 t)
Capacity 100 / 200 / 250 / 300 kg 0.5 / 1 / 2 / 3 / 5 t
Features 6 lines 6 lines, word-for-word same
Wiring 4-wire 4-wire, same
Sensitivity 2 / 3.0 (two values) 2 / 3.0, same
Other parameters 19 rows 19 rows, item-for-item same
Cable 3 m 3 m, same

⚠️ Why this is the highest-risk spot on the site: other "same parameters, different model" pairs at least carry different model numbers (HY-SBS-M vs HY-SBH-M); these two share even the model name and are distinguished only by the range in brackets. Check the range in three places: ① state "100-300 kg" or "0.5-5 t" on the purchase order; ② read the range on the nameplate at goods-in; ③ do not mix spares. This page does not decide which is "enough" — the ranges do not overlap, so pick by actual load.

Why two sensitivity values?

Short answer: the sensitivity cell carries two values — 2±0.002 and 3.0±0.002 — with no statement of which capacity step gets which. Both are transcribed; this page assigns neither. The same-name 0.5-5 t version is written the same way, and this two-value pattern recurs across HY-SQB, HY-HLJ-M and HY-SBH-M.

⚠️ Practical effect: cells with different sensitivity share the load in proportion to their sensitivity when paralleled, not equally. Mixing the two on one scale complicates calibration. Keep a batch consistent, or tell us which value you need.

How is it wired?

Short answer: 4-wire. The text and the drawing agree.

4-wire colour code (text and drawing agree)
Colour Terminal Function
RedEXC+ / +input+ excitation
BlackEXC− / −input− excitation
GreenSIG+ / +output+ signal
WhiteSIG− / −output− signal
thick blackSHIELDshield

⚠️ This is 4 wires plus one shield. The label on this unit writes the shield as "thick black" — note that siblings write "thick yellow", "long yellow" or pale-yellow, so work from the wire in hand, never copy a colour across models. Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, item-for-item identical to the same-name 0.5-5 t version.

HY-SQB (100-300 kg) specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002 / 3.0±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm3

What are the dimensions?

Short answer: the drawing gives one set of callouts (no capacity-grouped table — unlike the 0.5-5 t version). Units are unmarked, and some digits are small; only clearly readable values are transcribed.

Dimension callouts (from the drawing, units unmarked)
View Values shown
Body overall length 158, width 58, heights 31.8 / 25.1
Holes mounting holes 2-Φ8.5; centre spacing 78.2; right 25.4; left 15.7
Other centre bore Φ50; cable end 62 / 10.5

⚠️ Two notes: ① this version has no capacity table — all four steps share one set of callouts (the 0.5-5 t version has an 11-column table, so the drawings differ); ② units are unmarked and some digits are small — verify against the original drawing before machining.

What does it look like?

Short answer: four images are supplied — a product photograph, a wiring diagram and a dimension drawing. Three are used here.

HY-SQB (100-300 kg) load cell: natural alloy-steel bar body, cable leaving one end, a wiring label on the side (EXC+ red, EXC- black, SIG+ green, SIG- white, SHIELD thick black); factory watermark
The label spells out the four wires plus shield. Company documentation.
HY-SQB (100-300 kg) dimension drawing: top and side views with overall length 158, width 58, holes 2-Φ8.5; no capacity table
Dimension drawing (no capacity table; all four steps share it). Company documentation.
HY-SQB (100-300 kg) wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

Where does it fit, and where does it not?

Short answer: the documented applications are ground-level platforms and building-material batching, 100 to 300 kg.

The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

Resistances cannot tell sensitivity 2 from 3.0 — the resistances are identical. Check the nameplate or shipping documentation.

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: load per cell (this decides the range version), platform size and construction, indicator model (4-wire or 6-wire), whether a specific sensitivity is required, and washdown conditions.