First published · Chinese version: HY-PST 称重传感器

You are here: Home > Products > HY-PST

HY-PST Load Cell: S-Type, 20 kg to 5 t in 15 Steps, Laser-Welded IP68, 4-Wire

HY-PST is an S-type load cell, 20 kg to 5 t in 15 steps (the most steps of any model here). Alloy steel, laser-welded seal, IP68 on the 1.2-5 t steps and IP65 below, 4-wire. Several of its parameters differ from the rest of the range: sensitivity 2±0.003, output resistance 352±3 Ω, recommended excitation 10 to 12 V, and safe overload 120% (the lowest here).

Not sure about the step or the indicator match — tell us the load and the indicator model:

+86 183 5123 8137

Short answer: HY-PST covers 20, 30, 50, 75, 100, 200, 250, 300 and 500 kg plus 1.2, 1.5, 2, 2.5, 3 and 5 t; S-type, alloy steel, laser-welded seal, IP68 (1.2-5 t) / IP65; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity 2±0.003 mV/V, input 400±20 Ω, output 352±3 Ω, recommended excitation 10 to 12 V, operating range -20 to +60 °C, safe overload 120%, ultimate 200%.

Which parameters differ from the rest of the range?

Short answer: five of them — sensitivity 2±0.003 (most are ±0.002), output resistance 352±3 Ω (most are 350±1 or 700±1), recommended excitation 10 to 12 V (most are 5 to 15 V), safe overload 120% (the lowest here), and a protection rating that varies with capacity. These are not typos; they are transcribed as written — but they matter when matching an indicator or a spare.

Where this model differs (company documentation)
Item HY-PST (this page) Most models here
Sensitivity 2±0.003 2±0.002
Output resistance 352±3 350±1 or 700±1
Recommended excitation 10 to 12 V 5 to 15 V
Safe / ultimate overload 120% / 200% 150% / 300%
Protection IP65; IP68 for 1.2-5 t a single rating

⚠️ Four practical consequences: ① excitation 10–12 V is a narrow band — do not drive it at 5 V, the output would halve; ② safe overload is only 120%, below the 150% common here, so keep more margin and avoid high-impact duty; ③ sensitivity tolerance ±0.003 is wider than ±0.002, so paralleled cells match a little less closely; ④ protection depends on the step — you need 1.2 t or above for IP68.

Why does the protection read "IP65 IP68 (1.2-5t)"?

Short answer: the rating varies with capacity — the documentation writes both grades in one cell and notes that IP68 applies only to the 1.2-5 t steps. That wording is transcribed as written. Read conservatively: 20–500 kg steps at IP65, 1.2–5 t steps at IP68 — and confirm against the exact capacity when ordering.

Reading the two-value cell as written
Capacity band Steps Protection
20–500 kg 20, 30, 50, 75, 100, 200, 250, 300, 500 kg IP65
1.2–5 t 1.2, 1.5, 2, 2.5, 3, 5 t IP68 (documented)

⚠️ The original writes IP65 IP68(1.2-5t), the bracket naming the IP68 range. This page splits it that way rather than claiming IP68 across the whole range.

Why are there four cable lengths?

Short answer: the cable cell reads 2.6, 2.6, 2.6, 3 — four values in metres, with no statement of which capacity step gets which. All four are transcribed; none is assigned.

⚠️ How to use it: the spread is only 0.4 m (2.6 vs 3), so selection is barely affected, but confirm the lead length for your capacity when ordering. This page will not guess the mapping — a wrong guess makes the customer stock the wrong length.

How is it wired?

Short answer: 4-wire. The text and the drawing agree.

4-wire colour code (text and drawing agree)
Colour Terminal Function
RedExcitation(+)+ excitation
BlackExcitation(−)− excitation
GreenSignal(+)+ signal
WhiteSignal(−)− signal
thick blackShieldshield

⚠️ This is 4 wires plus one shield. Earth the shield at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, transcribed below.

HY-PST specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.003
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ400±20
Output resistanceΩ352±3
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)10 to 12
Maximum excitationV (DC/AC)20
Safe overload%R.C.120
Ultimate overload%R.C.200
Protection—IP65 IP68 (1.2-5 t)
Cable lengthm2.6, 2.6, 2.6, 3

Protection and cable length are both multi-value cells; they are transcribed as written and not assigned.

What are the dimensions?

Short answer: the drawing carries a three-row capacity table, but its range does not match the capacities on the product page. Only those three rows are copied; nothing is extrapolated.

Capacity table from the drawing (units unmarked)
Rated capacity D (thread) L H
20-150 kgM205290
200-500 kgM246090
700-1000 kgM30x269110

⚠️ Why only three rows: the drawing is titled "1.2-10 t", its table stops at 1000 kg, and the product page runs 20 kg to 5 t — the three do not agree. No dimensions exist on this sheet above 1.2 t, and this page does not interpolate. Ask us for the drawing of the specific capacity.

What does it look like?

Short answer: six images are supplied — product photographs, a wiring diagram and a dimension drawing with the three-row table. Three are used here.

HY-PST S-type load cell: alloy-steel S-shaped body with one threaded hole top and bottom, a wiring label on the side (+EXC red, -EXC black, +SIG green, -SIG white, SHIELD thick black); factory watermark
S-shaped body; the label spells out four wires plus shield. Company documentation.
HY-PST S-type dimension drawing: side and top views with a three-row capacity table (20-150 / 200-500 / 700-1000 kg giving D/L/H); the sheet title reads 1.2-10 t
Dimension drawing with the three-row table (title and table range disagree — see above). Company documentation.
HY-PST wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

Where does it fit, and where does it not?

Short answer: the documented applications are hanging-type weighing, packing scales, batching and mechanical-scale retrofits, 20 kg to 5 t.

The equipment named is the documented application — where this S-type cell is fitted — not a claim that this factory builds those machines. Hanging-type complete units are not made here; this page describes a load cell only.

How can I tell whether the cell has failed?

Short answer: input across red/black 400±20 Ω, output across green/white 352±3 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 400±20 Ω; open circuit means a broken internal wire
2 Measure green / white Around 352±3 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

⚠️ Do not borrow the 381/350 references — this model is 400/352, and the ±20 tolerance is wider than the ±4 of most models, so anything from 380 to 420 is normal.

Where do the facts come from?

No dimensions above 1.2 t; protection and cable length are multi-value cells — both stated plainly.

Still unsure which step fits?

Tell us: load per cell (kg or t), tension or compression, indicator model (can it supply 10–12 V?), mounting form (in-line or load-bearing), whether IP68 is needed, and impact severity.

Call +86 183 5123 8137