Which parameters differ from the rest of the range?
Short answer: five of them — sensitivity 2±0.003 (most are ±0.002), output resistance 352±3 Ω (most are 350±1 or 700±1), recommended excitation 10 to 12 V (most are 5 to 15 V), safe overload 120% (the lowest here), and a protection rating that varies with capacity. These are not typos; they are transcribed as written — but they matter when matching an indicator or a spare.
| Item | HY-PST (this page) | Most models here |
|---|---|---|
| Sensitivity | 2±0.003 | 2±0.002 |
| Output resistance | 352±3 | 350±1 or 700±1 |
| Recommended excitation | 10 to 12 V | 5 to 15 V |
| Safe / ultimate overload | 120% / 200% | 150% / 300% |
| Protection | IP65; IP68 for 1.2-5 t | a single rating |
⚠️ Four practical consequences: ① excitation 10–12 V is a narrow band — do not drive it at 5 V, the output would halve; ② safe overload is only 120%, below the 150% common here, so keep more margin and avoid high-impact duty; ③ sensitivity tolerance ±0.003 is wider than ±0.002, so paralleled cells match a little less closely; ④ protection depends on the step — you need 1.2 t or above for IP68.
Why does the protection read "IP65 IP68 (1.2-5t)"?
Short answer: the rating varies with capacity — the documentation writes both grades in one cell and notes that IP68 applies only to the 1.2-5 t steps. That wording is transcribed as written. Read conservatively: 20–500 kg steps at IP65, 1.2–5 t steps at IP68 — and confirm against the exact capacity when ordering.
| Capacity band | Steps | Protection |
|---|---|---|
| 20–500 kg | 20, 30, 50, 75, 100, 200, 250, 300, 500 kg | IP65 |
| 1.2–5 t | 1.2, 1.5, 2, 2.5, 3, 5 t | IP68 (documented) |
⚠️ The original writes IP65 IP68(1.2-5t), the bracket naming the IP68 range. This page splits it that way rather than claiming IP68 across the whole range.
Why are there four cable lengths?
Short answer: the cable cell reads 2.6, 2.6, 2.6, 3 — four values in metres, with no statement of which capacity step gets which. All four are transcribed; none is assigned.
⚠️ How to use it: the spread is only 0.4 m (2.6 vs 3), so selection is barely affected, but confirm the lead length for your capacity when ordering. This page will not guess the mapping — a wrong guess makes the customer stock the wrong length.
How is it wired?
Short answer: 4-wire. The text and the drawing agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | Excitation(+) | + excitation |
| Black | Excitation(−) | − excitation |
| Green | Signal(+) | + signal |
| White | Signal(−) | − signal |
| thick black | Shield | shield |
⚠️ This is 4 wires plus one shield. Earth the shield at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.003 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 400±20 |
| Output resistance | Ω | 352±3 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 10 to 12 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 120 |
| Ultimate overload | %R.C. | 200 |
| Protection | — | IP65 IP68 (1.2-5 t) |
| Cable length | m | 2.6, 2.6, 2.6, 3 |
Protection and cable length are both multi-value cells; they are transcribed as written and not assigned.
What are the dimensions?
Short answer: the drawing carries a three-row capacity table, but its range does not match the capacities on the product page. Only those three rows are copied; nothing is extrapolated.
| Rated capacity | D (thread) | L | H |
|---|---|---|---|
| 20-150 kg | M20 | 52 | 90 |
| 200-500 kg | M24 | 60 | 90 |
| 700-1000 kg | M30x2 | 69 | 110 |
⚠️ Why only three rows: the drawing is titled "1.2-10 t", its table stops at 1000 kg, and the product page runs 20 kg to 5 t — the three do not agree. No dimensions exist on this sheet above 1.2 t, and this page does not interpolate. Ask us for the drawing of the specific capacity.
What does it look like?
Short answer: six images are supplied — product photographs, a wiring diagram and a dimension drawing with the three-row table. Three are used here.
Where does it fit, and where does it not?
Short answer: the documented applications are hanging-type weighing, packing scales, batching and mechanical-scale retrofits, 20 kg to 5 t.
The equipment named is the documented application — where this S-type cell is fitted — not a claim that this factory builds those machines. Hanging-type complete units are not made here; this page describes a load cell only.
- Fits: S-type tension or compression measurement (one threaded hole top and bottom, suited to hanging or in-line mounting); packing scales; batching; retrofitting mechanical scales with a load cell.
- Why S-type: with one threaded hole at each end it takes both tension and compression and suits "in-line" mounting — unlike a beam (fixed both ends, loaded in the middle) or a column (aligned top and bottom compression).
- ⚠️ Three checks: ① excitation 10–12 V, do not drive it at 5 V; ② safe overload only 120%, keep margin; ③ IP68 applies only to the 1.2-5 t steps, smaller steps are IP65.
- Not covered: high-impact duty (low overload margin); 6-wire sense pair (HY-SBS-M / HY-SB-M); higher capacities (HY-SB-M to 20 t / HY-GD-M to 100 t).
How can I tell whether the cell has failed?
Short answer: input across red/black 400±20 Ω, output across green/white 352±3 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 400±20 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 352±3 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
⚠️ Do not borrow the 381/350 references — this model is 400/352, and the ±20 tolerance is wider than the ±4 of most models, so anything from 380 to 420 is normal.
Where do the facts come from?
- Company product documentation: five features, 4-wire colour code, 15 capacity steps, 19 technical parameters.
- Company images (six): product photographs (S-type), wiring diagram, dimension drawing with the three-row table.
- Parameter check against other models here: the other product pages (sensitivity, resistances, excitation, overload, protection).
- Public technical literature: how an S-type load path differs from beam and column types, and how excitation voltage affects output.
No dimensions above 1.2 t; protection and cable length are multi-value cells — both stated plainly.
Still unsure which step fits?
Tell us: load per cell (kg or t), tension or compression, indicator model (can it supply 10–12 V?), mounting form (in-line or load-bearing), whether IP68 is needed, and impact severity.