HY-0805 Load Cell: Compact, Self-Stabilising, 0.5 t to 2 t, 4-Wire, IP67

HY-0805 is a compact, low-profile, self-stabilising load cell, 0.5 t to 2 t in 3 steps, for batching on ground-level platforms and in chemical, food and medical plants. Alloy steel nickel-plated, IP67, 4-wire, 3 m cable. Its electrical parameters match HY-SBT item for item, but the outline is a different one.

Not sure between this and another model — tell us the mounting space and holes:

+86 183 5123 8137

Short answer: HY-0805 covers 0.5, 1 and 2 t; compact, low profile, self-stabilising, alloy steel nickel-plated, IP67; wiring is 4-wire (red = +excitation, black = −excitation, green = +signal, white = −signal); sensitivity 2±0.002 mV/V, input 381±4 Ω, output 350±1 Ω, operating range -20 to +60 °C, safe overload 150%, ultimate 300%, cable 3 m.

How does it differ from HY-SBT?

Short answer: the electrical parameters are item-for-item identical; the outline is a different one. Capacity (0.5–2 t), 4-wire, material, protection, all 19 parameters and cable length (3 m) are the same. What differs is the outline and the industries the documentation names.

HY-0805 vs HY-SBT (both pages of documentation plus both drawings)
Item HY-0805 (this page) HY-SBT
Capacity 0.5 to 2 t, 3 steps 0.5 to 2 t, 3 steps (same)
19 parameters item-for-item same item-for-item same
Wiring / cable 4-wire / 3 m 4-wire / 3 m (same)
Features 6 lines, including "self-stabilising structure" 6 lines, without it
Outline (drawing) overall about 167, width 58 overall 137, width 50.6, thread M12
Industries named ground-level, chemical, food, medical ground-level, building-material batching

⚠️ Two points: ① the two are electrically interchangeable but not mechanically — the overall length differs by about 30, so a base plate drilled for one will not take the other; ② "medical" is the word the documentation uses for this model; the siblings say "pharmaceutical". It is transcribed as written rather than normalised, because the two are not interchangeable in industry terms (medical devices and pharmaceutical production are different fields).

How is it wired?

Short answer: 4-wire. The text and the label on the unit agree.

4-wire colour code (text and unit label agree)
Colour Terminal Function
RedEXC+ / +input+ excitation
BlackEXC− / −input− excitation
GreenSIG+ / +output+ signal
WhiteSIG− / −output− signal
thick yellowSHIELDshield

⚠️ This is 4 wires plus one shield; the shield is not counted in "4-wire". Earth it at one end only.

What are the specifications?

Short answer: the company documentation gives 19 parameters, identical to HY-SBT.

HY-0805 specifications (company documentation)
Parameter Unit Value
SensitivitymV/V2±0.002
Non-repeatability%R.C.≤0.01
Hysteresis%R.C.≤0.02
Non-linearity%R.C.≤0.02
Creep (30 min)%R.C.≤0.02
Zero output%R.C.≤1
Compensated temperature range°C-10 to +40
Operating temperature range°C-20 to +60
Temperature effect on sensitivity%Load/°C≤0.002
Temperature effect on zero%R.C./°C≤0.002
Input resistanceΩ381±4
Output resistanceΩ350±1
Insulation resistanceMΩ≥5000 (50 V DC)
Recommended excitationV (DC/AC)5 to 15
Maximum excitationV (DC/AC)20
Safe overload%R.C.150
Ultimate overload%R.C.300
Protection—IP67
Cable lengthm3

What are the dimensions?

Short answer: the drawing gives one set of callouts (no capacity table). Units are unmarked and some digits are small; only clearly readable values are transcribed.

Dimension callouts (from the drawing, units unmarked)
View Values shown
Body overall 167, width 58, heights 31.8 / 25.1
Holes mounting holes 2-Φ8.5; centre spacing 78.2; right 25.4; left 15.7
Other centre bore Φ50; Φ20.5; cable end 30.5 / 28.5

⚠️ Two notes: ① no capacity table — all three steps share one set of callouts; ② units are unmarked and some digits are small — verify against the original drawing before machining. Against HY-SBT (overall 137, width 50.6, M12) this model is longer and wider; the two do not share a base-plate hole pattern.

What does it look like?

Short answer: four images are supplied — a product photograph, a wiring diagram and a dimension drawing. Three are used here.

HY-0805 load cell: natural alloy-steel bar body, compact, cable leaving one end, a wiring label on the side (EXC+ red, EXC- black, SIG+ green, SIG- white, SHIELD thick yellow); factory watermark
The label spells out the four wires plus shield. Company documentation.
HY-0805 dimension drawing: top and side views with overall about 167, width 58, holes 2-Φ8.5; no capacity table
Dimension drawing (no capacity table). Company documentation.
HY-0805 wiring diagram: Red excitation+, green signal+, Black excitation-, White signal-, pale-yellow shield
Wiring diagram (4-wire plus shield). Company documentation.

Where does it fit, and where does it not?

Short answer: the documented applications are batching on ground-level platforms and in chemical, food and medical plants, 0.5 to 2 t.

The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.

How can I tell whether the cell has failed?

Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.

Three checks that can be done on site
Step What to do What to look for
1 Power off; measure red / black Around 381±4 Ω; open circuit means a broken internal wire
2 Measure green / white Around 350±1 Ω
3 Measure insulation to body MΩ range (≥5000); a clear drop means moisture or a damaged seal

Where do the facts come from?

Values are transcribed from company documentation and are not a commitment for a specific project.

Still unsure which step fits?

Tell us: load per cell and cell count, the existing base-plate hole pattern (this model differs from HY-SBT), any height limit, indicator model (4-wire or 6-wire), and whether the site is corrosive or washed down.

Call +86 183 5123 8137