How does it differ from HY-SBT?
Short answer: the electrical parameters are item-for-item identical; the outline is a different one. Capacity (0.5–2 t), 4-wire, material, protection, all 19 parameters and cable length (3 m) are the same. What differs is the outline and the industries the documentation names.
| Item | HY-0805 (this page) | HY-SBT |
|---|---|---|
| Capacity | 0.5 to 2 t, 3 steps | 0.5 to 2 t, 3 steps (same) |
| 19 parameters | item-for-item same | item-for-item same |
| Wiring / cable | 4-wire / 3 m | 4-wire / 3 m (same) |
| Features | 6 lines, including "self-stabilising structure" | 6 lines, without it |
| Outline (drawing) | overall about 167, width 58 | overall 137, width 50.6, thread M12 |
| Industries named | ground-level, chemical, food, medical | ground-level, building-material batching |
⚠️ Two points: ① the two are electrically interchangeable but not mechanically — the overall length differs by about 30, so a base plate drilled for one will not take the other; ② "medical" is the word the documentation uses for this model; the siblings say "pharmaceutical". It is transcribed as written rather than normalised, because the two are not interchangeable in industry terms (medical devices and pharmaceutical production are different fields).
How is it wired?
Short answer: 4-wire. The text and the label on the unit agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | EXC+ / +input | + excitation |
| Black | EXC− / −input | − excitation |
| Green | SIG+ / +output | + signal |
| White | SIG− / −output | − signal |
| thick yellow | SHIELD | shield |
⚠️ This is 4 wires plus one shield; the shield is not counted in "4-wire". Earth it at one end only.
What are the specifications?
Short answer: the company documentation gives 19 parameters, identical to HY-SBT.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 |
| Cable length | m | 3 |
What are the dimensions?
Short answer: the drawing gives one set of callouts (no capacity table). Units are unmarked and some digits are small; only clearly readable values are transcribed.
| View | Values shown |
|---|---|
| Body | overall 167, width 58, heights 31.8 / 25.1 |
| Holes | mounting holes 2-Φ8.5; centre spacing 78.2; right 25.4; left 15.7 |
| Other | centre bore Φ50; Φ20.5; cable end 30.5 / 28.5 |
⚠️ Two notes: ① no capacity table — all three steps share one set of callouts; ② units are unmarked and some digits are small — verify against the original drawing before machining. Against HY-SBT (overall 137, width 50.6, M12) this model is longer and wider; the two do not share a base-plate hole pattern.
What does it look like?
Short answer: four images are supplied — a product photograph, a wiring diagram and a dimension drawing. Three are used here.
Where does it fit, and where does it not?
Short answer: the documented applications are batching on ground-level platforms and in chemical, food and medical plants, 0.5 to 2 t.
The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: small-capacity batching; sites with a limited mounting height (the first feature line is "compact, low profile"); food, chemical and medical batching.
- On "self-stabilising": the documentation lists it but does not describe how the structure works, and this page does not invent an explanation. Siblings HY-SBC-M, HY-HLJ-M and HY-SBH-M list it too.
- ⚠️ Two things to check: ① outline — this model is about 167 overall versus HY-SBT's 137, so no shared base plate; ② 4-wire without sense, so sense compensation needs a 6-wire model.
- Not covered: duties needing a sense pair (HY-SBS-M / HY-SB-M); IP68 (HY-HLJ-M / HY-SBH-M); higher capacities (HY-SB-M to 20 t / HY-GD-M to 100 t).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
Where do the facts come from?
- Company product documentation: six features, 4-wire colour code, 3 capacity steps, 19 technical parameters.
- Company images (four): product photograph with a wiring label, wiring diagram, dimension drawing (no capacity table).
- Item-by-item check against HY-SBT: both pages and both drawings (parameters identical; outline and industries differ).
- Public technical literature: 4-wire limits over long runs, how mounting height shapes a batching scale.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: load per cell and cell count, the existing base-plate hole pattern (this model differs from HY-SBT), any height limit, indicator model (4-wire or 6-wire), and whether the site is corrosive or washed down.