How does it differ from HY-PST?
Short answer: the same class of S-type structure; the differences are material, wiring, capacity band and how the sealing is done. This one is stainless steel with a laser weld and 6-wire, starting at 200 kg; HY-PST is alloy steel with 4-wire, starting at 20 kg.
| Item | HY-TSH-M (this page) | HY-PST |
|---|---|---|
| Material | stainless steel | alloy steel |
| Wiring | 6-wire (with sense) | 4-wire |
| Capacity | 200 kg to 5 t (7 steps) | 20 kg to 5 t (15 steps) |
| Protection | IP68 on all steps | IP65; IP68 from 1.2 to 5 t |
| Sensitivity | 2±0.002 | 2±0.003 |
| Cable | 5 m | 2.6 m / 3 m |
| Dimension table | 6 rows complete, matching the 7 steps | 3 rows, not matching the page range |
⚠️ Three selection points: ① corrosion or washdown ⇒ this model (stainless, IP68 throughout); ② sense compensation needed ⇒ this model is 6-wire; ③ below 200 kg (20/30/50/75/100 kg) ⇒ only HY-PST covers it.
Why do "stainless steel plus laser welding" matter?
Short answer: together they decide whether the cell lasts in wet, washed or mildly corrosive surroundings. Stainless resists corrosion; laser welding makes the body one continuous seal rather than relying on an O-ring or a thread.
- Stainless steel: unlike nickel-plated alloy steel, it does not suffer from long-term damp; food, chemical and pharmaceutical plants wash down often.
- Laser-welded seal: a continuous weld with no joint resists water ingress after thermal cycling better than glued or threaded seals.
- IP68 across the range: unlike models that vary by capacity, every step here is IP68.
⚠️ IP68 is not "anything can be immersed": it states dust and water protection, not resistance to acids, alkalis, salt spray or live steam. Those must be stated separately; add a shield or change material if needed.
What does 6-wire add over 4-wire?
Short answer: a sense pair (yellow / blue) that returns the excitation voltage actually seen by the cell back to the indicator. A 5 m cable is a medium run; with the sense pair connected, the excitation drop can be compensated.
| Wires | Includes | When it is enough |
|---|---|---|
| 4-wire | excitation +, excitation −, signal +, signal − | short cable, indicator nearby |
| 6-wire (this model) | the four above plus sense +, sense − | cable extended, wide temperature swing, or indicator with sense inputs |
⚠️ The reverse holds too: if the indicator has no sense terminals, the two extra wires do nothing. Confirm the terminals exist before ordering 6-wire.
How is it wired?
Short answer: 6-wire.
| Colour | Function | Terminal name |
|---|---|---|
| Green | + excitation | Excitation(+) |
| Black | − excitation | Excitation(−) |
| White | + signal | Signal(+) |
| Red | − signal | Signal(−) |
| Yellow | + sense | Sense(+) |
| Blue | − sense | Sense(−) |
⚠️ Here it is green = excitation+, white = signal+, red = signal−, not the 4-wire HY-1241 order (red = excitation+), so never carry a colour order across models.
What are the specifications?
Short answer: the company documentation gives 19 parameters, transcribed below. Note the +65 °C upper operating limit, five degrees above most models here.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +65 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP68 |
| Cable length | m | 5 |
What are the dimensions?
Direct answer: the drawing carries a complete six-row table that matches the seven capacity steps (0.2 and 0.3 share one row). The dimensions here can be used as printed.
| Capacity | L | H | W | Thread |
|---|---|---|---|---|
| 0.2 / 0.3 t | 62 | 80 | 30 | M10X1 |
| 0.5 t | 62 | 80 | 30 | M12X1 |
| 1 t | 70 | 90 | 30 | M12X1 |
| 2 t | 70 | 90 | 45 | M16X1.5 |
| 3 t | 80 | 100 | 50 | M18X1.5 |
| 5 t | 92 | 130 | 58 | M20X2.0 |
⚠️ Notes: units on the drawing are mm, transcribed as marked. 0.2 t and 0.3 t share one row (same dimensions, different capacity) — that is the drawing's own grouping, not a merge made here. Verify against the original drawing before machining.
What does it look like?
Short answer: five images are supplied — product photographs and one dimension drawing with the six-row table. Two are used here.
Where does it fit, and where does it not?
Short answer: the documented applications are hanging-type weighing, packing scales, batching and mechanical-scale retrofits, 200 kg to 5 t.
The equipment named is the documented application — where this S-type cell is fitted — not a claim that this factory builds those machines. Hanging-type complete units are not made here; this page describes a load cell only.
- Fits: sites needing corrosion resistance or washdown (stainless + IP68); 6-wire systems with sense compensation; in-line S-type mounting (one threaded hole each end, taking tension or compression).
- Why S-type helps: one threaded hole at each end means it takes both tension and compression and suits "in-line" mounting, unlike a beam (fixed both ends) or a column (aligned top and bottom compression).
- ⚠️ Three checks: ① capacity starts at 200 kg — smaller goes to HY-PST; ② 6-wire, so the indicator needs sense terminals; ③ IP68 does not solve cold (lower limit here is -20 °C).
- Not covered: below 200 kg (HY-PST from 20 kg); -40 °C duty (HY-SBC-M / HY-GD-M / HY-PGD-M); higher capacities (HY-SB-M to 20 t / HY-GD-M to 100 t).
How can I tell whether the cell has failed?
Short answer: input across green/black 381±4 Ω, output across white/red 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure green / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure white / red | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
This is 6-wire: the sense pair (yellow / blue) is not part of any of the three measurements. A broken sense wire leaves resistances normal while compensation fails silently.
Where do the facts come from?
- Company product documentation: four features, 6-wire colour code, 7 capacity steps, 19 technical parameters.
- Company images (five): product photographs of the stainless S-type body, dimension drawing with the six-row table.
- Item-by-item check against HY-PST: both pages and both drawings (material, wiring, capacity, protection, table completeness).
- Public technical literature: S-type load paths, laser welding versus glued sealing, and what a sense pair does.
Values are transcribed from company documentation and are not a commitment for a specific project.
Still unsure which step fits?
Tell us: load per cell (kg or t), tension or compression, indicator model (does it have sense terminals?), whether the site is corrosive or washed down, and the mounting space and thread required.