⚠️ First, a contradiction: is the protection IP68 or IP67?
Short answer: the documentation states both — IP68 in the second feature line, and IP67 in the parameter table. Both are transcribed here; this page does not choose one for you.
| Where | As written |
|---|---|
| Feature line 2 | Laser-welded seal, protection IP68 |
| Parameter table | Protection IP67 |
⚠️ The two ratings are not equivalent: IP67 covers brief immersion, IP68 covers continuous immersion. For a food or pharmaceutical line washed down every shift with a wet floor, that is a selection criterion. This page does not rule on which is right — confirm from the nameplate or the shipping documentation, or call and we will check it against your duty. HY-1241 on this site has the same kind of clash (IP65 in features / IP67 in the table), in the opposite direction, which points to document maintenance rather than a one-off typo.
What is it, and how does it relate to HY-HLJ-M?
Short answer: the same capacity range (0.5/1/2/3 t), the same wiring (both 4-wire), and even the same dimension drawing (identical table values). The real difference is the material: this one is stainless steel, HY-HLJ-M is alloy steel nickel-plated.
| Item | HY-SBH-M (this page) | HY-HLJ-M |
|---|---|---|
| Material | stainless steel, laser-welded | alloy steel, nickel-plated |
| Capacity | 0.5 to 3 t, 4 steps | 0.5 to 3 t, 4 steps (same) |
| Wiring | 4-wire | 4-wire (same) |
| Sensitivity | two values (2 / 3.0) | two values (same) |
| Protection | IP68 / IP67 clash | IP68 (consistent) |
| Cable | 5 m | 4.5 m |
| Dimension drawing | the same sheet | the same sheet |
⚠️ Selection: corrosion resistance and a hygienic finish point to this model (stainless); where those do not matter, HY-HLJ-M is the plated equivalent. The outlines are identical, so either fits the same holes. But this model's protection statement is contradictory — if IP68 is a hard requirement, confirm it first.
How is it wired?
Short answer: 4-wire. The text and the drawing agree.
| Colour | Terminal | Function |
|---|---|---|
| Red | EXC+ / +input | + excitation |
| Black | EXC− / −input | − excitation |
| Green | SIG+ / +output | + signal |
| White | SIG− / −output | − signal |
| pale-yellow | Shield | shield (drawing only) |
⚠️ This is 4 wires plus one shield; the shield is for interference and is not counted in "4-wire". Earth it at one end only. At 5 m this is a long 4-wire run, so assess the drop.
What are the specifications?
Short answer: the company documentation gives 19 parameters. Two sensitivity values and the protection clash are covered above.
| Parameter | Unit | Value |
|---|---|---|
| Sensitivity | mV/V | 2±0.002 / 3.0±0.002 |
| Non-repeatability | %R.C. | ≤0.01 |
| Hysteresis | %R.C. | ≤0.02 |
| Non-linearity | %R.C. | ≤0.02 |
| Creep (30 min) | %R.C. | ≤0.02 |
| Zero output | %R.C. | ≤1 |
| Compensated temperature range | °C | -10 to +40 |
| Operating temperature range | °C | -20 to +60 |
| Temperature effect on sensitivity | %Load/°C | ≤0.002 |
| Temperature effect on zero | %R.C./°C | ≤0.002 |
| Input resistance | Ω | 381±4 |
| Output resistance | Ω | 350±1 |
| Insulation resistance | MΩ | ≥5000 (50 V DC) |
| Recommended excitation | V (DC/AC) | 5 to 15 |
| Maximum excitation | V (DC/AC) | 20 |
| Safe overload | %R.C. | 150 |
| Ultimate overload | %R.C. | 300 |
| Protection | — | IP67 (features say IP68 — see above) |
| Cable length | m | 5 |
What are the dimensions? ⚠️ The drawing's capacity groups differ from the product page
Short answer: the drawing carries a readable capacity table, but its groups do not match the product page: the page lists 0.5/1/2/3 t, while the table lists "0.25/0.5/1 t, 2 t, 3 t, 5 t" — including 0.25 t and 5 t. It is reproduced as drawn and the discrepancy is stated.
| Capacity / kg | A | B | C | D | E | F | G | H | K | M | N | P | Q | S |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.25 / 0.5 / 1 t | 133.4 | 16.2 | 25.4 | 16.4 | 30.7 | 30 | 57.9 | 17 | 4.8 | 12.7 | 22 | 15.9 | 3.1 | 7.7 |
| 2 t | 138.7 | 16.2 | 25.4 | 16.7 | 30.8 | 35.8 | 57.9 | 23 | 9.5 | 12.7 | 22 | 15.9 | 3.1 | 11.7 |
| 3 t | 139.7 | 19.2 | 25.4 | 16.7 | 39 | 35.6 | 57.9 | 23 | 9.5 | 16 | 22 | 15.9 | — | — |
| 5 t | 171.5 | 95.2 | 38.1 | 16.7 | 42.9 | 43 | 73.8 | 29.4 | 11 | 19 | 34.9 | 22.2 | 3.1 | 11.7 |
⚠️ Three points: ① the drawing has 0.25 t and 5 t groups that the page does not list — transcribed as-is, nothing added or removed; ask us if you need those steps; ② the Q and S cells of the 3 t row are blank on the drawing, not omissions here; ③ this table is identical to the HY-HLJ-M one (the two share the drawing), so the outlines match and the holes are interchangeable. Column A runs 133.4 to 171.5 — use the row for your capacity.
What does it look like?
Short answer: four images are supplied — product photographs, one dimension drawing with the capacity table, and one wiring diagram. Three are used here.
Where does it fit, and where does it not?
Short answer: the documented applications are ground-level platforms and batching in chemical, food and pharmaceutical plants, 0.5 to 3 t.
The equipment and industries named above are the documented applications — where this cell goes — not a claim that this factory builds complete platforms.
- Fits: chemical, food and pharmaceutical batching; sites needing a stainless finish and corrosion resistance; washdown areas (but confirm the IP rating first, see above).
- Why stainless: food, pharmaceutical and chemical plants use corrosive media and cleaning; a plated finish wears through under prolonged washdown.
- ⚠️ Three things to confirm: ① IP68 or IP67 (the documentation contradicts itself); ② two sensitivity values — keep a batch consistent; ③ the drawing lists 0.25 t / 5 t that the page does not.
- Not covered: duties needing a sense pair (6-wire models); dry duties where stainless is unnecessary (HY-HLJ-M is the plated equivalent); high capacities (HY-SBD / HY-QS).
How can I tell whether the cell has failed?
Short answer: input across red/black 381±4 Ω, output across green/white 350±1 Ω, insulation to body ≥5000 MΩ.
| Step | What to do | What to look for |
|---|---|---|
| 1 | Power off; measure red / black | Around 381±4 Ω; open circuit means a broken internal wire |
| 2 | Measure green / white | Around 350±1 Ω |
| 3 | Measure insulation to body | MΩ range (≥5000); a clear drop means moisture or a damaged seal |
On a stainless washdown cell, watch the insulation in particular — a damaged seal shows there first. Resistances cannot tell sensitivity 2 from 3.0.
Where do the facts come from?
- Company product documentation: six features (including the IP68 wording), 4-wire colour code, 4 capacity steps, 19 parameters (including the IP67 wording and the dual sensitivity).
- Company images (four): product photographs with a wiring label, a dimension drawing with the 14-column table, and a wiring diagram.
- Check against HY-HLJ-M: both pages plus the shared drawing (material and cable differ; the rest matches).
- Public technical literature: stainless versus plated parts under corrosive washdown, IP67 versus IP68.
Both inconsistencies — the IP68/IP67 clash and the drawing's extra capacity groups — are transcribed unchanged.
Still unsure which step fits?
Tell us: load per cell and cell count, whether IP68 is required (and how the line is washed), the corrosiveness of the medium, indicator model (4-wire or 6-wire), and mounting space and hole pattern.