What is a full-floating weighing module, and where does it mount?
Short answer: a weighing module is a practical structural accessory for load cells, built from a top plate, a base plate, the load cell, a load-bearing column and support bolts. Depending on the load-bearing column and the top plate, modules fall into three structures: fixed, semi-floating and floating; this page covers the full-floating one, the structure public technical literature writes as floating. (Public technical literature, "Selection and installation of weighing modules".)
A module mounts easily on vessels of almost any shape and suits retrofits: whether a vessel, a hopper or a reactor, adding modules and a weight indicator turns it into a weighing system. (Public technical literature, same source.)
Mounting position is usually the lower part of the scale body — feet, pallet and similar — or the upper part, at the waist of a vessel, tank or hopper. All modules of one weighing system must sit in the same horizontal plane. (Public technical literature, same source.)
How it differs from buying a load cell on its own
A module makes the load cell, the load-bearing structure and the mounting connection one assembly: bolt it under a foot and it takes load, so part of the weighing error caused by poor installation is absorbed by the structure itself. A bare load cell leaves the load point, the restraint and the mounting face for the fitter to solve. (Public technical literature, same source.)
This type carries one more structural feature of its own at that level: the main features in company documentation list an SBS cantilever-beam load cell, so the pairing of load element and support arrangement is written for this type and is not the same arrangement as the other structures in the family. (Company product documentation.)
Where it sits in a weighing system
A weighing control system is normally made of a weight indicator, a junction box, the weighing modules and cable: the modules take the load, the junction box sums the signals of several modules, the indicator displays and controls. (Company installation instructions.)
A system usually uses 3 to 6 sets of modules, up to 12. The foundation carrying the modules must meet the stiffness requirement and lie in one plane, or be adjustable to one plane, so that every module carries an even share. (Company installation instructions.)
How do full-floating, fixed and semi-floating differ, and how many of each go into one system?
Short answer: the three are separated by the load-bearing column and the top plate, not by capacity: in one weighing system, use one fixed module and one semi-floating module, and fill the remaining positions with floating modules; a set is usually three modules or four, three for three-point support and four for four-point support. The full-floating type is therefore the one used in the greatest number per system: apart from that one fixed and one semi-floating module, every remaining position takes it. (Public technical literature, "Selection and installation of weighing modules".)
Two names for one structure: company documentation calls it full-floating, while public technical literature calls the corresponding structure floating; the two mean one and the same structure, not two products. This page keeps the company name, full-floating, and keeps the wording floating only where industry material is quoted. (Company product documentation plus public technical literature, "Selection and installation of weighing modules".)
Where it differs from the fixed type: both are product names cut from the same structural division, so the difference sits in the structural features. Against the fixed type, the main features in company documentation add one line for this type: an SBS cantilever-beam load cell. That line is the support feature of this structure and the point to read carefully at selection time; the surrounding requirements — mounting method, support bolts against tipping — are written here from this type's own documentation. (Company product documentation.)
That also explains how this page differs from the model pages: HY-CWC-M and HY-CWC describe a specific model, where capacity, material, wiring and dimensions follow the model. This page and the fixed weighing module page describe a structural type — which module goes where in a system, and how many of each. In one system, confirm the exact model and capacity for the fixed, semi-floating and full-floating positions together, and take the number of modules from the number of support points.
| Item | Content | Source |
|---|---|---|
| How many structures | Depending on the load-bearing column and the top plate: fixed, semi-floating and floating | Public technical literature, "Selection and installation of weighing modules" |
| How one system is made up | One fixed module and one semi-floating module, the remaining positions filled with floating modules | Public technical literature, "Selection and installation of weighing modules" |
| Usual set sizes | Usually a set of three or a set of four; three for three-point support, four for four-point support | Public technical literature, "Selection and installation of weighing modules" |
| Position of this type | It is that remainder: apart from the one fixed and one semi-floating module, every remaining position takes this type, which makes it the one used in the greatest number of the three structures | Public technical literature, "Selection and installation of weighing modules" |
| Two names for one structure | Same structure: company documentation says full-floating, public technical literature says floating | Company product documentation and public technical literature, "Selection and installation of weighing modules" |
| Structural feature of this type | The main features in company documentation include "uses an SBS cantilever-beam load cell" (the fixed type's main features do not list this line) | Company product documentation |
| Confirming an order | This page describes a structural type, not an ordering code; confirm the exact model and capacity when ordering | Company product documentation |
The table lists how the three structures are divided and how many of each are used; the part-to-model mapping is checked on the model pages. Sizing method and worked examples are on Selection & Resources.
What are the specifications, and where does each value come from?
Short answer: the table lists this structure's product values with their source, and the right-hand column turns each value into what it determines at sizing and installation time. Figures are transcribed as printed: not converted, not merged, and nothing added that the documentation does not contain. The company documentation states no capacity, no protection rating, no accuracy figure and no long-term stability figure for this structure, so those four have no row here and no value is inferred.
| Parameter | Value (source) | What it determines |
|---|---|---|
| Model / product name | Full-floating weighing module Company product documentation | A product name defined by the load-bearing column and the top plate (three structures: fixed / semi-floating / floating), not an ordering code; the same structure is full-floating in company documentation and floating in public technical literature. Confirm the exact model and capacity when ordering. (Public technical literature plus company product documentation.) |
| Category | Weighing module Company product documentation | A structural part plus a load cell: at sizing time look at capacity, material and mounting dimensions together, not at the load cell figures alone. |
| Material and surface finish | Alloy steel structure; nickel-plated surface Company product documentation | Alloy steel is the strength base of the load-bearing parts; nickel plating is the anti-corrosion route. Plating is a surface treatment, while stainless steel hermetic welding is a different anti-corrosion route, so do not apply another model's material wording to this structure. |
| Structural features | Can be mounted directly on the floor or on a foundation structure; uses an SBS cantilever-beam load cell; support bolts prevent the equipment from tipping Company product documentation | Mounting straight onto floor or foundation keeps the foundation requirement simple; the SBS cantilever-beam load cell sets the load element and the support arrangement, and is where this type differs from the other structures in the family; the support bolts give it a built-in anti-tip measure, which is the item to check on site when the vessel takes horizontal impact. |
| Wiring system | 4-wire with shield (+excitation, −excitation, +signal, −signal, plus one shield wire) Company product documentation and specification drawing | 4-wire with shield is the simplest connection: two excitation wires, two signal wires and a shield, with no sense wires. The shield suppresses interference from variable-frequency drives and power cable; the field practice is to earth the shield at one end and keep signal cable away from power cable. (Practice from public technical literature.) |
| Colour code | Red = +excitation; black = −excitation; green = +signal; white = −signal (4 wires). The wiring diagram on the company specification drawing also marks light yellow = shield. One documented difference has to be stated as it stands: the nameplate on the physical unit of this type carries a different 6-wire set — green = +excitation, yellow = +sense, white = +signal, red = −signal, blue = −sense, yellow (long) = shield — which differs from the 4-wire set above in both wire count and colour order. This page transcribes the 4-wire set from company product documentation and the specification drawing, records the nameplate set as found, does not set the two out as two tables side by side, and does not choose between them for the customer; for installation follow the documentation shipped with the unit and the wiring diagram on the unit. Company product documentation (4 wires transcribed as printed), specification drawing and the nameplate as found | The field reference for terminating. Colour order differs between models in the public installation material, and this type carries two documented sets of its own, so before work starts follow the documentation shipped with the unit and the wiring diagram on the unit, and do not copy colours from another model. |
| Wiring diagram | Red = excitation+; green = signal+; black = excitation−; white = signal−; light yellow = shield Company specification drawing (drawing 3 below) | One shield wire more than the colour code row: the shield suppresses drive and power-cable interference, and the field practice is to earth it at one end and keep signal cable away from power cable. (Practice from public technical literature.) |
| Dimensions | Lateral drawing: 150, 124, 4-Ø11, 102, 3, 32, 226, 286, 4-Ø13; end view: 128, 102, 28, 80, 112, 23 (the drawings mark no unit; transcribed as printed) Company specification drawings (drawings 4 and 5 below) | How tall the module stands, where the mounting holes go and what the hole spacing is. Before changing a module or a foundation, measure the existing hole positions and available height, then check them against these two sets; the drawings mark no unit and state no corresponding capacity or model step, and none is inferred here. |
| Documented applications | Suited to platform scales, mixing plants and batching scales Company product documentation | This row states a direction of use, not a claim that any such site will fit: for a specific machine, still check vessel dead weight, product weight, number of feet and site conditions. |
All values and wording are transcribed from company documentation as printed, including the fact that a value is not given. Every explanation added on this page carries its own source and is public technical literature, not a company commitment. The company documentation states no capacity, no protection rating, no accuracy figure and no long-term stability figure for this structure: those four rows are not set, and no value is inferred.
Which value applies in which working condition?
Short answer: check the single-module capacity first against "dead load + live load ≤ rated capacity × number of modules × 70%", then set the number of modules from the number of support points, then complete the set across the three structures: one fixed, one semi-floating, the rest full-floating. The company documentation does not state a capacity for this structure, so confirm the exact model and capacity against the working condition. (Sizing approach from public technical literature.)
dead load + live load ≤ rated capacity × number of modules × 70%
The formula is written out in words so it can be copied, sent to a work group or printed for a design office; the wording is quoted from public technical literature. Worked examples are on Selection & Resources.
Static or dynamic load first: how the material enters the vessel
Static-load modules suit mainly static weighing where lateral forces are small; dynamic-load modules suit machinery that takes horizontal forces, such as production lines and conveyors. (Public technical literature, "Selection and installation of weighing modules".)
When material is fed vertically into a hopper, tank, reactor or silo by conveyor or pump, use static-load modules. When material is fed horizontally onto the scale or into the vessel, a horizontal impact force appears, and dynamic-load modules should be used. (Public technical literature, same source.)
Case by case (can be followed directly)
| Your case | What to take | Basis |
|---|---|---|
| The vessel already has support feet | Set the count from the number of feet: 3 feet, 3 modules; 4 feet, 4 modules. Of these, 1 fixed and 1 semi-floating, the remaining positions made up by full-floating modules | Module count from public technical literature; the three-structure arrangement from public technical literature, "Selection and installation of weighing modules" |
| New vessel, vertical cylinder | Three-point support is the more stable choice; where wind, sway or vibration matter, four-point support is preferred | Public technical literature |
| Calculated single-module capacity falls between two steps | Take the next step up, not down | Public technical literature |
| Material is fed horizontally into the vessel | A horizontal impact force appears; use dynamic-load modules | Public technical literature, "Selection and installation of weighing modules" |
| Long cable run from module to indicator | This structure is 4-wire with shield and has no sense wires; earth the shield at one end, keep signal cable away from power cable, and check against the indicator terminals | Wiring system from company product documentation; shield practice from public technical literature |
| Replacing an old module without changing the foundation | Measure the existing hole positions and available height first, then check them against the two dimension sets on this page | Dimensions from company specification drawings |
Where does it fit, and where does it not?
Short answer: what company product documentation and the sourced content on this page support is the "platform scales, mixing plants and batching scales" group of sites, plus the mounting method that comes with "can be mounted directly on the floor or a foundation structure, with support bolts against tipping". What the company documentation does not give — capacity, protection rating, accuracy and long-term stability, material grade, service temperature — is not inferred here and is not decided on the customer's behalf.
Fits (with a source)
- Platform scales, mixing plants and batching scales: the documented applications row states that the structure suits these. (Company product documentation.)
- On the floor or on a foundation structure: this structure can be mounted directly on the floor or on a foundation structure, with support bolts to prevent the equipment from tipping. (Company product documentation.)
- Retrofitting existing equipment: modules mount easily on vessels of almost any shape and suit retrofits, whether a vessel, a hopper or a reactor. (Public technical literature, "Selection and installation of weighing modules".)
- Where structural duties must be split inside one system: one fixed and one semi-floating module per system, the remaining positions filled with full-floating modules, for three-point or four-point support. (Public technical literature, same source.)
Limits and cases that do not apply
- Capacity, protection rating, accuracy and long-term stability are not stated for this structure: none of the four can be inferred here, no value is published and no row is set; where any of them matters, check the specific model and the working condition. (Basis: the company product documentation does not record them.)
- This page is not an ordering page: fixed / semi-floating / floating are product names divided by structure, so quote the exact model and capacity rather than the words "full-floating" alone. (Basis: public technical literature, "Selection and installation of weighing modules".)
- Never mix modules of different capacity in one weighing system. (Company installation instructions.)
- Welding current must not pass through the load cell: no current through the module during welding, or the cell is damaged. (Company installation instructions.)
- The vessel must not be tied mechanically to any part that the modules do not carry, or the reading will be wrong. (Public technical literature, "Selection and installation of weighing modules".)
- Product piping left unhandled spoils the reading: run every pipe connected to the vessel horizontally so it does not hang the vessel, use flexible connections where possible, and keep the first pipe support point as far from the vessel as possible. (Public technical literature, same source.)
What do the specification drawings show, and why is there no photograph?
Short answer: the five images below are all company specification drawings: mounting arrangement, module layout (with the three structures shown inside), wiring diagram, dimension drawing in side view, and dimension drawing in end view. No usable photograph of the physical unit was available for this type this time, so the outward appearance is governed by the specification drawings and by the documentation shipped with the unit. All images are local files; the page loads no external resource.
Five specification drawings, used unaltered. No usable photograph of the physical unit was available for this type this time, so the outward appearance follows the specification drawings and the documentation shipped with the unit. Neither dimension drawing marks a unit, and none is added here. Where an image and the written documentation disagree, the written documentation governs.
What matters during installation and wiring?
Short answer: whether a module performs comes down to three things: base stiffness and level, connection verticality, and whether force bypasses such as piping and welding have been dealt with. Each row below gives a figure or an action that can be checked, from public installation literature and the company installation instructions.
| Item | Requirement | Source |
|---|---|---|
| Verticality | The vertical axis of every module coincides with the perpendicular to the mounting plate, deviation not more than 1.5°; correct with shims where it is out | Company installation instructions |
| Frame and base plate stiffness | Frame and base plate carrying the modules must be rigid enough; stiffness of 1/1000 is required | Company installation instructions |
| Bracket skew | Skew or twist of the upper bracket and the base bracket relative to horizontal must not exceed 0.5° | Public technical literature, "Selection and installation of weighing modules" |
| Foundation | The foundation or floor carrying the vessel must have enough bearing capacity and stiffness, with deflection below 3 mm; a concrete foundation is the better choice | Public technical literature, "Selection and installation of weighing modules" |
| Fixing method | Once the module is shimmed level, fix it either with bolts or by welding; no welding current may pass through the weighing module | Company installation instructions |
| Levelling | With the module under a vessel foot or bracket, rock the top plate by hand; if it moves, the module is not level, so shim it until it does not move | Company installation instructions |
| Bolting | Tighten every bolt diagonally, pre-tighten first, then torque to specification | Company installation instructions |
| Load and axis | Upper and lower mounting faces of every module fully connected, with no unevenness, and load shared evenly; where unevenness or skew appears, correct it with shims or equivalent | Company installation instructions |
| Cable | Do not stretch the cable, or tension will affect electrical performance; protect the cable and keep the sheath free of cuts | Company installation instructions |
| Handling | Never lift the module by its cable when taking it out of the packing; avoid knocks and prevent drops from height | Company installation instructions |
| Piping | Run every pipe connected to the vessel horizontally so the pipe does not hang the vessel; set the first pipe support point as far from the vessel as possible and use flexible connections where possible | Public technical literature, "Selection and installation of weighing modules" |
| Calibration conditions | Allow for test-weight positions and for jacking points used during installation and service at the design stage; give every module its own earth, and calibrate after installation | Public technical literature, "Selection and installation of weighing modules" |
| Wiring and re-check | Wire the load cell cable to the junction box as the diagram requires, run the cable from junction box to indicator, re-check every connection and verify the supply voltage; the colour order follows the documentation shipped with the unit and the diagram on the unit | Company installation instructions |
The table collects general requirements from public installation literature and the company installation instructions, and applies to installing this class of module; field practice and the final judgement still follow the documentation shipped with the unit and the actual working condition. Indicator-side checks and calibration faults are covered on the FAQ page.
Where do the facts come from?
- Company product documentation (full-floating weighing module product data): product name, category, material and surface finish, structural features including the SBS cantilever-beam load cell, 4-wire connection and colour code, documented applications.
- Company product specification drawings: mounting arrangement, module layout with the three structures, 4-wire with shield wiring diagram, dimension drawings in side view and end view.
- Company installation instructions: installation deviation and stiffness requirements, the two fixing methods, the prohibitions on mixing capacities and on welding current, levelling and handling, wiring and re-check.
- Public technical literature ("Selection and installation of weighing modules" and similar, marked at each sentence it supports): module construction, the three structures and module counts, static versus dynamic criteria, foundation and piping requirements, calibration conditions.
- The nameplate as found: the separate 6-wire colour set printed on the physical unit, recorded as it stands.
Values in the tables are transcribed from company documentation and are not a commitment for a specific project; capacity, protection rating, accuracy and long-term stability are not stated for this structure and none is inferred. Final specifications are confirmed against the working condition. First published 2026-10-16 on the Chinese page; this English page first published 2026-10-24.
Still unsure how many full-floating modules a set needs?
Tell us these in one go and we can answer on structure and count directly: vessel dead weight, product weight, number and layout of support feet, how the material enters the vessel, site conditions, and whether it is a new build or a retrofit.
- All weighing modules, by structure and model →
- Sizing formula, worked examples, the four duties and the eight installation faults →
- Fixed weighing module, the other structural type page, usually used once per system →
- HY-GW weighing module, 15 t to 100 t, stainless steel IP68, with side tie rods →
- The reading is wrong or keeps jumping: what to check first →